{"product_id":"omron-e2e-next-basic-single-distance-proximity-sensor-m8-shielded-dc-3-wire-io-link-npn-pnp","title":"Omron E2E NEXT BASIC Single distance Proximity Sensor (M8, Shielded, DC 3-Wire, IO-Link, NPN\/PNP)","description":"\u003cp class=\"ps-intro\"\u003eOMRON E2E NEXT Series BASIC Single distance cylindrical proximity sensor.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eM8 body, Shielded\u003c\/li\u003e\n\u003cli\u003eSensing distance 1.5 mm (standard body)\u003c\/li\u003e\n\u003cli\u003eDC 3-wire\u003c\/li\u003e\n\u003cli\u003ePNP IO-Link COM3\/COM2 and NPN\u003c\/li\u003e\n\u003cli\u003eNO\/NC\/NO+NC\u003c\/li\u003e\n\u003cli\u003ePre-wired 2m\/5m, M12 Smartclick 0.3m, M12\/M8 connector\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003ctd\u003eM8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensing Distance\u003c\/th\u003e\n\u003ctd\u003e1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShield\u003c\/th\u003e\n\u003ctd\u003eShielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGrade\u003c\/th\u003e\n\u003ctd\u003eBASIC Single distance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote\u003c\/th\u003e\n\u003ctd\u003eIO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1T8 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM3 NO 2m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1T8 5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM3 NO 5m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1T8-M1TJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM3 NO Smartclick 0.3m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1T8-M1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM3 NO M12 conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1T8-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM3 NO M8 4pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M8 Connector 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1T8-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM3 NO M8 3pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M8 Connector 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1D8 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM2 NO 2m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1D8 5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM2 NO 5m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1D8-M1TJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM2 NO Smartclick 0.3m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1D8-M1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM2 NO M12 conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1D8-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM2 NO M8 4pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M8 Connector 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1D8-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM2 NO M8 3pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M8 Connector 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C18 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO 2m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C18 5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO 5m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C18-M1TJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO Smartclick 0.3m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C18-M1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO M12 conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C18-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO M8 4pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M8 Connector 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C18-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO M8 3pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M8 Connector 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B28 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NC 2m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B28 5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NC 5m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B28-M1TJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NC Smartclick 0.3m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B28-M1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NC M12 conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B28-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NC M8 4pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M8 Connector 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B28-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NC M8 3pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M8 Connector 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C28 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NC 2m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C28 5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NC 5m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C28-M1TJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NC Smartclick 0.3m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C28-M1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NC M12 conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C28-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NC M8 4pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M8 Connector 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C28-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NC M8 3pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M8 Connector 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1TL8 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM3 NO 2m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1TL8 5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM3 NO 5m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1TL8-M1TJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM3 NO Smartclick 0.3m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1TL8-M1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM3 NO M12 conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1TL8-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM3 NO M8 4pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M8 Connector 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1TL8-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM3 NO M8 3pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M8 Connector 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1DL8 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM2 NO 2m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1DL8 5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM2 NO 5m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1DL8-M1TJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM2 NO Smartclick 0.3m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1DL8-M1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM2 NO M12 conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1DL8-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM2 NO M8 4pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M8 Connector 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B1DL8-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP IO-Link COM2 NO M8 3pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M8 Connector 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C1L8 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO 2m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C1L8 5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO 5m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C1L8-M1TJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO Smartclick 0.3m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C1L8-M1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO M12 conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C1L8-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO M8 4pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M8 Connector 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C1L8-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO M8 3pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M8 Connector 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B2L8 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NC 2m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B2L8 5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NC 5m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B2L8-M1TJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NC Smartclick 0.3m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B2L8-M1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NC M12 conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B2L8-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NC M8 4pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M8 Connector 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B2L8-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NC M8 3pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M8 Connector 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C2L8 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NC 2m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C2L8 5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NC 5m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C2L8-M1TJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NC Smartclick 0.3m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C2L8-M1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NC M12 conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C2L8-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NC M8 4pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M8 Connector 4-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C2L8-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NC M8 3pin conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M8 Connector 3-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B3DL8 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NO+NC 2m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B3DL8 5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NO+NC 5m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B3DL8-M1TJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NO+NC Smartclick | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5B3DL8-M1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm PNP NO+NC M12 conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C3L8 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO+NC 2m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C3L8 5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO+NC 5m | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C3L8-M1TJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO+NC Smartclick | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2E-X1R5C3L8-M1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2E NEXT M8 1.5 mm NPN NO+NC M12 conn | Size: M8 | Sensing Distance: 1.5 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":67396660592930,"sku":"OMRON-E2EN-3W-S-SH-M8","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-367_a3c00b95-42e5-4d77-9ce5-2510f1071947.png?v=1790663519","url":"https:\/\/prosourcemro.com\/products\/omron-e2e-next-basic-single-distance-proximity-sensor-m8-shielded-dc-3-wire-io-link-npn-pnp","provider":"ProSource MRO","version":"1.0","type":"link"}