{"product_id":"omron-e2er-oil-resistant-proximity-sensor-standard-shielded-fluororesin-cable","title":"Omron E2ER Oil-resistant Proximity Sensor (Standard, Shielded, Fluororesin Cable)","description":"\u003cp class=\"ps-intro\"\u003eOMRON E2ER Oil-resistant Shielded Proximity Sensor — Environment-resistant Series.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eFluororesin cable sheath and heat-welded joint seal block cutting oil ingress for 4-year stable operation\u003c\/li\u003e\n\u003cli\u003eSizes M8\/M12\/M18\/M30 with sensing distances 2\/3\/7\/10 mm. 10-30 VDC, 100 mA load, NO (D1) or NC (D2) operation\u003c\/li\u003e\n\u003cli\u003eIP67G (JIS C 0920 Annex 1)\u003c\/li\u003e\n\u003cli\u003eOperating temperature −25 to +70 °C\u003c\/li\u003e\n\u003cli\u003ePre-wired (2 m fluororesin cable) or M12 Smartclick Pre-wired Connector (0.3 m) variants\u003c\/li\u003e\n\u003cli\u003eVerified against 13 representative water-soluble and 6 water-insoluble cutting oils\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eShielded (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetectable Object\u003c\/th\u003e\n\u003ctd\u003eFerrous metal (sensing distance decreases with non-ferrous metal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e10-30 VDC (10% ripple p-p)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLeakage Current\u003c\/th\u003e\n\u003ctd\u003e0.8 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad Current\u003c\/th\u003e\n\u003ctd\u003e3-100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResidual Voltage\u003c\/th\u003e\n\u003ctd\u003e3 V max (100 mA load, 2 m cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection Circuits\u003c\/th\u003e\n\u003ctd\u003eSurge suppressor \/ Load short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eOperating −25 to +70 °C \/ Storage −40 to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Humidity\u003c\/th\u003e\n\u003ctd\u003e35-95% RH (operating and storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Influence\u003c\/th\u003e\n\u003ctd\u003e±1% max at rated voltage ±15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Resistance\u003c\/th\u003e\n\u003ctd\u003e50 MΩ min at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDielectric Strength\u003c\/th\u003e\n\u003ctd\u003e1,000 VAC 50\/60 Hz 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X2D1 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M8 shielded proximity, 2 mm ±10%, NO, Pre-wired (2 m) | Size: M8 | Type: Shielded (standard) | Sensing Distance: 2 mm ±10% | Set Distance: 0-1.6 mm | Differential Travel: 15% max (M8) \/ 10% max (M12-M30) | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 8×8×1 mm | Response Frequency: 1.5 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NO (1: Operation indicator red + Setting indicator green) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: Pre-wired (2 m) | Cable Specification: 3.6 mm fluoro-insulated (0.2 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±15% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 500 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Stainless steel (SUS303) | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: — | Weight (Packed): approx. 65 g | Compatible Connector: — | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X2D1-M1TGJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M8 shielded proximity, 2 mm ±10%, NO, M12 Pre-wired Smartclick Connector (0.3 m) | Size: M8 | Type: Shielded (standard) | Sensing Distance: 2 mm ±10% | Set Distance: 0-1.6 mm | Differential Travel: 15% max (M8) \/ 10% max (M12-M30) | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 8×8×1 mm | Response Frequency: 1.5 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NO (1: Operation indicator red + Setting indicator green) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: M12 Pre-wired Smartclick Connector (0.3 m) | Cable Specification: 3.6 mm fluoro-insulated (0.2 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±15% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 500 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Stainless steel (SUS303) | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: — | Weight (Packed): approx. 30 g | Compatible Connector: XS5FR-D423-D80-RB1 (2 m) \/ -G80-RB1 (5 m) \/ -J80-RB1 (10 m), sold separately | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X2D2 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M8 shielded proximity, 2 mm ±10%, NC, Pre-wired (2 m) | Size: M8 | Type: Shielded (standard) | Sensing Distance: 2 mm ±10% | Set Distance: 0-1.6 mm | Differential Travel: 15% max (M8) \/ 10% max (M12-M30) | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 8×8×1 mm | Response Frequency: 1.5 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NC (2: Operation indicator red only) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: Pre-wired (2 m) | Cable Specification: 3.6 mm fluoro-insulated (0.2 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±15% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 500 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Stainless steel (SUS303) | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: — | Weight (Packed): approx. 65 g | Compatible Connector: — | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X2D2-M1TGJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M8 shielded proximity, 2 mm ±10%, NC, M12 Pre-wired Smartclick Connector (0.3 m) | Size: M8 | Type: Shielded (standard) | Sensing Distance: 2 mm ±10% | Set Distance: 0-1.6 mm | Differential Travel: 15% max (M8) \/ 10% max (M12-M30) | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 8×8×1 mm | Response Frequency: 1.5 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NC (2: Operation indicator red only) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: M12 Pre-wired Smartclick Connector (0.3 m) | Cable Specification: 3.6 mm fluoro-insulated (0.2 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±15% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 500 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Stainless steel (SUS303) | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: — | Weight (Packed): approx. 30 g | Compatible Connector: XS5FR-D423-D80-RB1 (2 m) \/ -G80-RB1 (5 m) \/ -J80-RB1 (10 m), sold separately | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X3D1 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M12 shielded proximity, 3 mm ±10%, NO, Pre-wired (2 m) | Size: M12 | Type: Shielded (standard) | Sensing Distance: 3 mm ±10% | Set Distance: 0-2.4 mm | Differential Travel: 10% max of sensing distance | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 12×12×1 mm | Response Frequency: 1 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NO (1: Operation indicator red + Setting indicator green) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: Pre-wired (2 m) | Cable Specification: 3.6 mm fluoro-insulated (0.2 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±10% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 1000 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Nickel-plated brass | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: Nickel-plated brass | Weight (Packed): approx. 75 g | Compatible Connector: — | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X3D1-M1TGJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M12 shielded proximity, 3 mm ±10%, NO, M12 Pre-wired Smartclick Connector (0.3 m) | Size: M12 | Type: Shielded (standard) | Sensing Distance: 3 mm ±10% | Set Distance: 0-2.4 mm | Differential Travel: 10% max of sensing distance | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 12×12×1 mm | Response Frequency: 1 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NO (1: Operation indicator red + Setting indicator green) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: M12 Pre-wired Smartclick Connector (0.3 m) | Cable Specification: 3.6 mm fluoro-insulated (0.2 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±10% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 1000 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Nickel-plated brass | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: Nickel-plated brass | Weight (Packed): approx. 40 g | Compatible Connector: XS5FR-D423-D80-RB1 (2 m) \/ -G80-RB1 (5 m) \/ -J80-RB1 (10 m), sold separately | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X3D2 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M12 shielded proximity, 3 mm ±10%, NC, Pre-wired (2 m) | Size: M12 | Type: Shielded (standard) | Sensing Distance: 3 mm ±10% | Set Distance: 0-2.4 mm | Differential Travel: 10% max of sensing distance | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 12×12×1 mm | Response Frequency: 1 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NC (2: Operation indicator red only) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: Pre-wired (2 m) | Cable Specification: 3.6 mm fluoro-insulated (0.2 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±10% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 1000 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Nickel-plated brass | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: Nickel-plated brass | Weight (Packed): approx. 75 g | Compatible Connector: — | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X3D2-M1TGJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M12 shielded proximity, 3 mm ±10%, NC, M12 Pre-wired Smartclick Connector (0.3 m) | Size: M12 | Type: Shielded (standard) | Sensing Distance: 3 mm ±10% | Set Distance: 0-2.4 mm | Differential Travel: 10% max of sensing distance | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 12×12×1 mm | Response Frequency: 1 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NC (2: Operation indicator red only) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: M12 Pre-wired Smartclick Connector (0.3 m) | Cable Specification: 3.6 mm fluoro-insulated (0.2 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±10% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 1000 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Nickel-plated brass | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: Nickel-plated brass | Weight (Packed): approx. 40 g | Compatible Connector: XS5FR-D423-D80-RB1 (2 m) \/ -G80-RB1 (5 m) \/ -J80-RB1 (10 m), sold separately | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X7D1 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M18 shielded proximity, 7 mm ±10%, NO, Pre-wired (2 m) | Size: M18 | Type: Shielded (standard) | Sensing Distance: 7 mm ±10% | Set Distance: 0-5.6 mm | Differential Travel: 10% max of sensing distance | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 18×18×1 mm | Response Frequency: 0.5 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NO (1: Operation indicator red + Setting indicator green) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: Pre-wired (2 m) | Cable Specification: 5.0 mm fluoro-insulated (0.5 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±10% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 1000 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Nickel-plated brass | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: Nickel-plated brass | Weight (Packed): approx. 145 g | Compatible Connector: — | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X7D1-M1TGJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M18 shielded proximity, 7 mm ±10%, NO, M12 Pre-wired Smartclick Connector (0.3 m) | Size: M18 | Type: Shielded (standard) | Sensing Distance: 7 mm ±10% | Set Distance: 0-5.6 mm | Differential Travel: 10% max of sensing distance | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 18×18×1 mm | Response Frequency: 0.5 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NO (1: Operation indicator red + Setting indicator green) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: M12 Pre-wired Smartclick Connector (0.3 m) | Cable Specification: 5.0 mm fluoro-insulated (0.5 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±10% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 1000 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Nickel-plated brass | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: Nickel-plated brass | Weight (Packed): approx. 90 g | Compatible Connector: XS5FR-D423-D80-RB1 (2 m) \/ -G80-RB1 (5 m) \/ -J80-RB1 (10 m), sold separately | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X7D2 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M18 shielded proximity, 7 mm ±10%, NC, Pre-wired (2 m) | Size: M18 | Type: Shielded (standard) | Sensing Distance: 7 mm ±10% | Set Distance: 0-5.6 mm | Differential Travel: 10% max of sensing distance | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 18×18×1 mm | Response Frequency: 0.5 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NC (2: Operation indicator red only) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: Pre-wired (2 m) | Cable Specification: 5.0 mm fluoro-insulated (0.5 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±10% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 1000 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Nickel-plated brass | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: Nickel-plated brass | Weight (Packed): approx. 145 g | Compatible Connector: — | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X7D2-M1TGJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M18 shielded proximity, 7 mm ±10%, NC, M12 Pre-wired Smartclick Connector (0.3 m) | Size: M18 | Type: Shielded (standard) | Sensing Distance: 7 mm ±10% | Set Distance: 0-5.6 mm | Differential Travel: 10% max of sensing distance | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 18×18×1 mm | Response Frequency: 0.5 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NC (2: Operation indicator red only) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: M12 Pre-wired Smartclick Connector (0.3 m) | Cable Specification: 5.0 mm fluoro-insulated (0.5 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±10% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 1000 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Nickel-plated brass | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: Nickel-plated brass | Weight (Packed): approx. 90 g | Compatible Connector: XS5FR-D423-D80-RB1 (2 m) \/ -G80-RB1 (5 m) \/ -J80-RB1 (10 m), sold separately | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X10D1 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M30 shielded proximity, 10 mm ±10%, NO, Pre-wired (2 m) | Size: M30 | Type: Shielded (standard) | Sensing Distance: 10 mm ±10% | Set Distance: 0-8 mm | Differential Travel: 10% max of sensing distance | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 30×30×1 mm | Response Frequency: 0.4 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NO (1: Operation indicator red + Setting indicator green) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: Pre-wired (2 m) | Cable Specification: 5.0 mm fluoro-insulated (0.5 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±10% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 1000 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Nickel-plated brass | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: Nickel-plated brass | Weight (Packed): approx. 215 g | Compatible Connector: — | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X10D1-M1TGJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M30 shielded proximity, 10 mm ±10%, NO, M12 Pre-wired Smartclick Connector (0.3 m) | Size: M30 | Type: Shielded (standard) | Sensing Distance: 10 mm ±10% | Set Distance: 0-8 mm | Differential Travel: 10% max of sensing distance | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 30×30×1 mm | Response Frequency: 0.4 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NO (1: Operation indicator red + Setting indicator green) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: M12 Pre-wired Smartclick Connector (0.3 m) | Cable Specification: 5.0 mm fluoro-insulated (0.5 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±10% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 1000 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Nickel-plated brass | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: Nickel-plated brass | Weight (Packed): approx. 155 g | Compatible Connector: XS5FR-D423-D80-RB1 (2 m) \/ -G80-RB1 (5 m) \/ -J80-RB1 (10 m), sold separately | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X10D2 2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M30 shielded proximity, 10 mm ±10%, NC, Pre-wired (2 m) | Size: M30 | Type: Shielded (standard) | Sensing Distance: 10 mm ±10% | Set Distance: 0-8 mm | Differential Travel: 10% max of sensing distance | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 30×30×1 mm | Response Frequency: 0.4 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NC (2: Operation indicator red only) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: Pre-wired (2 m) | Cable Specification: 5.0 mm fluoro-insulated (0.5 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±10% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 1000 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Nickel-plated brass | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: Nickel-plated brass | Weight (Packed): approx. 215 g | Compatible Connector: — | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2ER-X10D2-M1TGJ 0.3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eE2ER M30 shielded proximity, 10 mm ±10%, NC, M12 Pre-wired Smartclick Connector (0.3 m) | Size: M30 | Type: Shielded (standard) | Sensing Distance: 10 mm ±10% | Set Distance: 0-8 mm | Differential Travel: 10% max of sensing distance | Detectable Object: Ferrous metal (sensing distance decreases with non-ferrous metal) | Standard Sensing Object: Iron 30×30×1 mm | Response Frequency: 0.4 kHz | Power Supply: 10-30 VDC (10% ripple p-p) | Leakage Current: 0.8 mA max | Load Current: 3-100 mA | Residual Voltage: 3 V max (100 mA load, 2 m cable) | Operation Mode: NC (2: Operation indicator red only) | Protection Circuits: Surge suppressor \/ Load short-circuit protection | Connection: M12 Pre-wired Smartclick Connector (0.3 m) | Cable Specification: 5.0 mm fluoro-insulated (0.5 mm² conductor) | Ambient Temperature: Operating −25 to +70 °C \/ Storage −40 to +85 °C | Ambient Humidity: 35-95% RH (operating and storage) | Temperature Influence: ±10% max at 23 °C in −25 to +70 °C range | Voltage Influence: ±1% max at rated voltage ±15% | Insulation Resistance: 50 MΩ min at 500 VDC | Dielectric Strength: 1,000 VAC 50\/60 Hz 1 min | Vibration Resistance: 10-55 Hz 1.5 mm double amplitude, 2 h each X\/Y\/Z | Shock Resistance: 1000 m\/s² 10 times each X\/Y\/Z | Degree of Protection: IP67 (IEC 60529) + IP67G (JIS C 0920 Annex 1) | Case Material: Nickel-plated brass | Sensing Surface: Polybutylene terephthalate (PBT) | Clamping Nuts: Nickel-plated brass | Weight (Packed): approx. 155 g | Compatible Connector: XS5FR-D423-D80-RB1 (2 m) \/ -G80-RB1 (5 m) \/ -J80-RB1 (10 m), sold separately | Extended Cable Length: 5 m version available with '5M' suffix (e.g., E2ER-X2D1 5M) | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":67396653941026,"sku":"OMRON-E2ER","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-313.png?v=1790663316","url":"https:\/\/prosourcemro.com\/products\/omron-e2er-oil-resistant-proximity-sensor-standard-shielded-fluororesin-cable","provider":"ProSource MRO","version":"1.0","type":"link"}