{"product_id":"omron-e3nx-ma-standard-2-channel-smart-fiber-amplifier-dual-fiber-input-2-outputs-8-logic-modes","title":"Omron E3NX-MA Standard 2-Channel Smart Fiber Amplifier (Dual Fiber Input, 2 Outputs, 8 Logic Modes)","description":"\u003cp class=\"ps-intro\"\u003e⭐ 2-channel smart fiber amplifier — single unit with the dimensions of a standard 1-unit amplifier delivers two-channel functionality, reducing installation space by half and enabling smaller equipment and control panels.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eConnect two fiber units to one amplifier (4 fiber unit holes vs 2 in standard E3NX-FA)\u003c\/li\u003e\n\u003cli\u003eGIGA RAY light source for stable detection from transparent objects to low-reflective workpieces\u003c\/li\u003e\n\u003cli\u003eSmart Tuning auto-configures both channels' optimum settings\u003c\/li\u003e\n\u003cli\u003eAPC + DPC auto-compensation for maintenance-free operation\u003c\/li\u003e\n\u003cli\u003eFour response modes (SHS 100μs ~ GIGA 16ms)\u003c\/li\u003e\n\u003cli\u003eWhite 7-segment + green sub-display\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eI\/O Configuration\u003c\/th\u003e\n\u003ctd\u003e2 outputs (one per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003eNormal: 960mW max. (40mA @ 24VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECO ON\u003c\/th\u003e\n\u003ctd\u003e770mW (32mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eECO LO\u003c\/th\u003e\n\u003ctd\u003e870mW (36mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Output\u003c\/th\u003e\n\u003ctd\u003eNPN or PNP open-collector, 30 VDC max., 2 outputs (one per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad Current\u003c\/th\u003e\n\u003ctd\u003e100 mA max. (1-3 amps), 20 mA max. (4-30 amps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResidual Voltage\u003c\/th\u003e\n\u003ctd\u003e1 V max. (\u0026lt;10 mA load) \/ 2 V max. (10-100 mA load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOFF Current\u003c\/th\u003e\n\u003ctd\u003e0.1 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse Time — SHS (Super-high-speed)\u003c\/th\u003e\n\u003ctd\u003e100 μs operate\/reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse Time — HS (High-speed)\u003c\/th\u003e\n\u003ctd\u003e450 μs operate\/reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse Time — Stnd (Standard)\u003c\/th\u003e\n\u003ctd\u003e1 ms operate\/reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse Time — GIGA (Giga-power)\u003c\/th\u003e\n\u003ctd\u003e16 ms operate\/reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE3NX-MA11\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOMRON E3NX-MA11 standard 2-channel smart fiber amplifier, NPN, 2-output, 2m pre-wired. | Output: NPN | I\/O Configuration: 2 outputs (one per channel) | Connection: Pre-wired (2m cable, 4 dia., 4 conductors) | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 770mW (32mA) | ECO LO: 870mW (36mA) | Control Output: NPN or PNP open-collector, 30 VDC max., 2 outputs (one per channel) | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4-30 amps) | Residual Voltage: 1 V max. (\u0026lt;10 mA load) \/ 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 100 μs operate\/reset | Response Time — HS (High-speed): 450 μs operate\/reset | Response Time — Stnd (Standard): 1 ms operate\/reset | Response Time — GIGA (Giga-power): 16 ms operate\/reset | Channel Usage Note: ⚠️ If using only 1 channel, do NOT leave the unused channel's output cable unwired — incident level changes on unused channel may produce incorrect output. Use both channels or wire both outputs. | Light Source: Red 4-element LED (625 nm) | Channels: ⭐ 2-channel — single amplifier supports two fiber units simultaneously (4 fiber unit holes) | Display: 7-segment digital display — sub digital (green) + main digital (white), reversible | Indicators: OUT1\/OUT2 (orange), OUT1\/OUT2 selection (orange), L\/D (orange), ST (blue, smart tuning), DPC (green, dynamic power control) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning \/ Full auto tuning \/ Position tuning \/ Maximum sensitivity tuning \/ Power tuning \/ Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Provided — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: Disabled \/ OFF-delay \/ ON-delay \/ One-shot \/ ON-delay+OFF-delay (1ms to 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON \/ OFF selectable | Eco Mode: OFF (display lit) \/ ECO ON (display off) \/ ECO LO (display dimmed) | Output 1 Mode: Standard detection \/ Area detection | Output 2 Mode (8 options): Standard detection \/ AND output \/ OR output \/ XOR output \/ GAP output \/ Falling synchronization \/ Rising synchronization \/ Area detection — leverage 2-channel for advanced logic | Hysteresis Width: Standard or User-set (0~9999 range) | Zero Reset: Supported (negative values displayable, threshold shifted) | Setting Reset: Initial reset (factory defaults) \/ User reset (saved settings) | Mutual Interference Prevention: 9 units (HS\/Stnd\/GIGA modes, optical sync). SHS mode: disabled. NOT compatible with E3C\/E2C\/E3X series. | Maximum Connectable Units: 30 units | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50\/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X\/Y\/Z) | Shock Resistance: 500 m\/s² × 3 times each axis | Degree of Protection: IEC 60529 IP50 (with Protective Cover attached) | Material: Case\/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | Mobile Console Compatibility: E3X-MC11\/MC11-SV2\/MC11-S NOT supported | Communications Unit Compatibility: E3X-DRT21-S \/ E3X-CRT \/ E3X-ECT NOT compatible (Standard Type and High-function Type cannot use these)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE3NX-MA41\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOMRON E3NX-MA41 standard 2-channel smart fiber amplifier, PNP, 2-output, 2m pre-wired. | Output: PNP | I\/O Configuration: 2 outputs (one per channel) | Connection: Pre-wired (2m cable, 4 dia., 4 conductors) | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 770mW (32mA) | ECO LO: 870mW (36mA) | Control Output: NPN or PNP open-collector, 30 VDC max., 2 outputs (one per channel) | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4-30 amps) | Residual Voltage: 1 V max. (\u0026lt;10 mA load) \/ 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 100 μs operate\/reset | Response Time — HS (High-speed): 450 μs operate\/reset | Response Time — Stnd (Standard): 1 ms operate\/reset | Response Time — GIGA (Giga-power): 16 ms operate\/reset | Channel Usage Note: ⚠️ If using only 1 channel, do NOT leave the unused channel's output cable unwired — incident level changes on unused channel may produce incorrect output. Use both channels or wire both outputs. | Light Source: Red 4-element LED (625 nm) | Channels: ⭐ 2-channel — single amplifier supports two fiber units simultaneously (4 fiber unit holes) | Display: 7-segment digital display — sub digital (green) + main digital (white), reversible | Indicators: OUT1\/OUT2 (orange), OUT1\/OUT2 selection (orange), L\/D (orange), ST (blue, smart tuning), DPC (green, dynamic power control) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning \/ Full auto tuning \/ Position tuning \/ Maximum sensitivity tuning \/ Power tuning \/ Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Provided — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: Disabled \/ OFF-delay \/ ON-delay \/ One-shot \/ ON-delay+OFF-delay (1ms to 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON \/ OFF selectable | Eco Mode: OFF (display lit) \/ ECO ON (display off) \/ ECO LO (display dimmed) | Output 1 Mode: Standard detection \/ Area detection | Output 2 Mode (8 options): Standard detection \/ AND output \/ OR output \/ XOR output \/ GAP output \/ Falling synchronization \/ Rising synchronization \/ Area detection — leverage 2-channel for advanced logic | Hysteresis Width: Standard or User-set (0~9999 range) | Zero Reset: Supported (negative values displayable, threshold shifted) | Setting Reset: Initial reset (factory defaults) \/ User reset (saved settings) | Mutual Interference Prevention: 9 units (HS\/Stnd\/GIGA modes, optical sync). SHS mode: disabled. NOT compatible with E3C\/E2C\/E3X series. | Maximum Connectable Units: 30 units | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50\/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X\/Y\/Z) | Shock Resistance: 500 m\/s² × 3 times each axis | Degree of Protection: IEC 60529 IP50 (with Protective Cover attached) | Material: Case\/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | Mobile Console Compatibility: E3X-MC11\/MC11-SV2\/MC11-S NOT supported | Communications Unit Compatibility: E3X-DRT21-S \/ E3X-CRT \/ E3X-ECT NOT compatible (Standard Type and High-function Type cannot use these)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE3NX-MA6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOMRON E3NX-MA6 standard 2-channel smart fiber amplifier, NPN, 2-output, wire-saving connector. | Output: NPN | I\/O Configuration: 2 outputs (one per channel) | Connection: Wire-saving connector — E3X-CN21 Master (4-conductor) \/ E3X-CN22 Slave (2-conductor) sold separately | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 770mW (32mA) | ECO LO: 870mW (36mA) | Control Output: NPN or PNP open-collector, 30 VDC max., 2 outputs (one per channel) | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4-30 amps) | Residual Voltage: 1 V max. (\u0026lt;10 mA load) \/ 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 100 μs operate\/reset | Response Time — HS (High-speed): 450 μs operate\/reset | Response Time — Stnd (Standard): 1 ms operate\/reset | Response Time — GIGA (Giga-power): 16 ms operate\/reset | Channel Usage Note: ⚠️ If using only 1 channel, do NOT leave the unused channel's output cable unwired — incident level changes on unused channel may produce incorrect output. Use both channels or wire both outputs. | Light Source: Red 4-element LED (625 nm) | Channels: ⭐ 2-channel — single amplifier supports two fiber units simultaneously (4 fiber unit holes) | Display: 7-segment digital display — sub digital (green) + main digital (white), reversible | Indicators: OUT1\/OUT2 (orange), OUT1\/OUT2 selection (orange), L\/D (orange), ST (blue, smart tuning), DPC (green, dynamic power control) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning \/ Full auto tuning \/ Position tuning \/ Maximum sensitivity tuning \/ Power tuning \/ Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Provided — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: Disabled \/ OFF-delay \/ ON-delay \/ One-shot \/ ON-delay+OFF-delay (1ms to 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON \/ OFF selectable | Eco Mode: OFF (display lit) \/ ECO ON (display off) \/ ECO LO (display dimmed) | Output 1 Mode: Standard detection \/ Area detection | Output 2 Mode (8 options): Standard detection \/ AND output \/ OR output \/ XOR output \/ GAP output \/ Falling synchronization \/ Rising synchronization \/ Area detection — leverage 2-channel for advanced logic | Hysteresis Width: Standard or User-set (0~9999 range) | Zero Reset: Supported (negative values displayable, threshold shifted) | Setting Reset: Initial reset (factory defaults) \/ User reset (saved settings) | Mutual Interference Prevention: 9 units (HS\/Stnd\/GIGA modes, optical sync). SHS mode: disabled. NOT compatible with E3C\/E2C\/E3X series. | Maximum Connectable Units: 30 units | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50\/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X\/Y\/Z) | Shock Resistance: 500 m\/s² × 3 times each axis | Degree of Protection: IEC 60529 IP50 (with Protective Cover attached) | Material: Case\/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | Mobile Console Compatibility: E3X-MC11\/MC11-SV2\/MC11-S NOT supported | Communications Unit Compatibility: E3X-DRT21-S \/ E3X-CRT \/ E3X-ECT NOT compatible (Standard Type and High-function Type cannot use these)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE3NX-MA8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOMRON E3NX-MA8 standard 2-channel smart fiber amplifier, PNP, 2-output, wire-saving connector. | Output: PNP | I\/O Configuration: 2 outputs (one per channel) | Connection: Wire-saving connector — E3X-CN21 Master (4-conductor) \/ E3X-CN22 Slave (2-conductor) sold separately | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 770mW (32mA) | ECO LO: 870mW (36mA) | Control Output: NPN or PNP open-collector, 30 VDC max., 2 outputs (one per channel) | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4-30 amps) | Residual Voltage: 1 V max. (\u0026lt;10 mA load) \/ 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 100 μs operate\/reset | Response Time — HS (High-speed): 450 μs operate\/reset | Response Time — Stnd (Standard): 1 ms operate\/reset | Response Time — GIGA (Giga-power): 16 ms operate\/reset | Channel Usage Note: ⚠️ If using only 1 channel, do NOT leave the unused channel's output cable unwired — incident level changes on unused channel may produce incorrect output. Use both channels or wire both outputs. | Light Source: Red 4-element LED (625 nm) | Channels: ⭐ 2-channel — single amplifier supports two fiber units simultaneously (4 fiber unit holes) | Display: 7-segment digital display — sub digital (green) + main digital (white), reversible | Indicators: OUT1\/OUT2 (orange), OUT1\/OUT2 selection (orange), L\/D (orange), ST (blue, smart tuning), DPC (green, dynamic power control) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning \/ Full auto tuning \/ Position tuning \/ Maximum sensitivity tuning \/ Power tuning \/ Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Provided — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: Disabled \/ OFF-delay \/ ON-delay \/ One-shot \/ ON-delay+OFF-delay (1ms to 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON \/ OFF selectable | Eco Mode: OFF (display lit) \/ ECO ON (display off) \/ ECO LO (display dimmed) | Output 1 Mode: Standard detection \/ Area detection | Output 2 Mode (8 options): Standard detection \/ AND output \/ OR output \/ XOR output \/ GAP output \/ Falling synchronization \/ Rising synchronization \/ Area detection — leverage 2-channel for advanced logic | Hysteresis Width: Standard or User-set (0~9999 range) | Zero Reset: Supported (negative values displayable, threshold shifted) | Setting Reset: Initial reset (factory defaults) \/ User reset (saved settings) | Mutual Interference Prevention: 9 units (HS\/Stnd\/GIGA modes, optical sync). SHS mode: disabled. NOT compatible with E3C\/E2C\/E3X series. | Maximum Connectable Units: 30 units | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50\/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X\/Y\/Z) | Shock Resistance: 500 m\/s² × 3 times each axis | Degree of Protection: IEC 60529 IP50 (with Protective Cover attached) | Material: Case\/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | Mobile Console Compatibility: E3X-MC11\/MC11-SV2\/MC11-S NOT supported | Communications Unit Compatibility: E3X-DRT21-S \/ E3X-CRT \/ E3X-ECT NOT compatible (Standard Type and High-function Type cannot use these)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":67396653154594,"sku":"OMRON-E3NX-MA-STD","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-5.png?v=1790663311","url":"https:\/\/prosourcemro.com\/products\/omron-e3nx-ma-standard-2-channel-smart-fiber-amplifier-dual-fiber-input-2-outputs-8-logic-modes","provider":"ProSource MRO","version":"1.0","type":"link"}