{"product_id":"omron-g3na-solid-state-relay-hockey-puck-5-90a-240-480vacdc-ul-csa-tuv","title":"Omron G3NA Solid State Relay (Hockey-puck, 5-90A, 240\/480VAC+DC, UL\/CSA\/TÜV)","description":"\u003cp class=\"ps-intro\"\u003eThe reliable choice for Hockey-puck-style Solid State Relays.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\u003cli\u003eAvailable in a Wide Range of Currents\u003c\/li\u003e\u003c\/ul\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-205B-UTU DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 5A 24-240VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 5A \/ 24-240 VAC | Input: 5-24 VDC | Isolation: Phototriac | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-205B-UTU AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 5A 24-240VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 5A \/ 24-240 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-210B-UTU DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 10A 24-240VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 10A \/ 24-240 VAC | Input: 5-24 VDC | Isolation: Phototriac | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-210B-UTU AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 10A 24-240VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 10A \/ 24-240 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-220B-UTU DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 20A 24-240VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 20A \/ 24-240 VAC | Input: 5-24 VDC | Isolation: Phototriac | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-220B-UTU AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 20A 24-240VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 20A \/ 24-240 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-225B-UTU DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 25A 24-240VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 25A \/ 24-240 VAC | Input: 5-24 VDC | Isolation: Phototriac | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-225B-UTU AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 25A 24-240VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 25A \/ 24-240 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-240B-UTU DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 40A 24-240VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 40A \/ 24-240 VAC | Input: 5-24 VDC | Isolation: Phototriac | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-240B-UTU AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 40A 24-240VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 40A \/ 24-240 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-250B-UTU DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 50A 24-240VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 50A \/ 24-240 VAC | Input: 5-24 VDC | Isolation: Phototriac | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-250B-UTU AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 50A 24-240VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 50A \/ 24-240 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-275B-UTU-2 DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 75A 24-240VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 75A \/ 24-240 VAC | Input: 5-24 VDC | Isolation: Phototriac | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-275B-UTU-2 AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 75A 24-240VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 75A \/ 24-240 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-290B-UTU-2 DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 90A 24-240VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 90A \/ 24-240 VAC | Input: 5-24 VDC | Isolation: Phototriac | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-290B-UTU-2 AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 90A 24-240VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 90A \/ 24-240 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Indicator: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-410B-UTU DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 10A 200-480VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 10A \/ 200-480 VAC | Input: 5-24 VDC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-410B-UTU AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 10A 200-480VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 10A \/ 200-480 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-420B-UTU DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 20A 200-480VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 20A \/ 200-480 VAC | Input: 5-24 VDC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-420B-UTU AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 20A 200-480VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 20A \/ 200-480 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-425B-UTU-2 DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 25A 200-480VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 25A \/ 200-480 VAC | Input: 5-24 VDC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-425B-UTU-2 AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 25A 200-480VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 25A \/ 200-480 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-440B-UTU-2 DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 40A 200-480VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 40A \/ 200-480 VAC | Input: 5-24 VDC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-440B-UTU-2 AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 40A 200-480VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 40A \/ 200-480 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-450B-UTU-2 DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 50A 200-480VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 50A \/ 200-480 VAC | Input: 5-24 VDC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-450B-UTU-2 AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 50A 200-480VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 50A \/ 200-480 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-475B-UTU-2 DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 75A 200-480VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 75A \/ 200-480 VAC | Input: 5-24 VDC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-475B-UTU-2 AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 75A 200-480VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 75A \/ 200-480 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-490B-UTU-2 DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 90A 200-480VAC 5-24 VDC | Type: G3NA SSR (Hockey-puck) | Load: 90A \/ 200-480 VAC | Input: 5-24 VDC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-490B-UTU-2 AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 90A 200-480VAC 100-240 VAC | Type: G3NA SSR (Hockey-puck) | Load: 90A \/ 200-480 VAC | Input: 100-240 VAC | Isolation: Photocoupler | Zero Cross: Yes | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-D210B-UTU DC5-24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 10A 5-200VDC 5-24 VDC | Type: G3NA SSR (Hockey-puck, DC load) | Load: 10A \/ 5-200 VDC | Input: 5-24 VDC | Zero Cross: --- | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG3NA-D210B-UTU AC100-240\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA 10A 5-200VDC 100-240 VAC | Type: G3NA SSR (Hockey-puck, DC load) | Load: 10A \/ 5-200 VDC | Input: 100-240 VAC | Zero Cross: --- | Note: Load current depends on ambient temperature and heat sink. UL\/CSA\/TÜV certified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR99-12 FOR G3NA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA One-touch Mounting Plate | Type: G3NA Mounting Plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY92B-N50\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA Heat Sink DIN Y92B-N50 | Type: G3NA Heat Sink (DIN Track) | Applicable: G3NA-205B\/210B\/D210B\/410B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY92B-N100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA Heat Sink DIN Y92B-N100 | Type: G3NA Heat Sink (DIN Track) | Applicable: G3NA-220B\/420B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY92B-N150\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA Heat Sink DIN Y92B-N150 | Type: G3NA Heat Sink (DIN Track) | Applicable: G3NA-225B\/240B\/425B\/440B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY92B-P250\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA Heat Sink DIN Y92B-P250 | Type: G3NA Heat Sink (DIN Track) | Applicable: G3NA-250B\/450B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY92B-P250NF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA Heat Sink DIN Y92B-P250NF | Type: G3NA Heat Sink (DIN Track) | Applicable: G3NA-275B\/290B\/475B\/490B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY92B-A100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA Heat Sink Screw Y92B-A100 | Type: G3NA Heat Sink (Screw) | Applicable: G3NA-205B\/210B\/D210B\/220B\/410B\/420B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY92B-A150N\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA Heat Sink Screw Y92B-A150N | Type: G3NA Heat Sink (Screw) | Applicable: G3NA-225B\/240B\/425B\/440B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eY92B-A250\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eG3NA Heat Sink Screw Y92B-A250 | Type: G3NA Heat Sink (Screw) | Applicable: G3NA-440B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":67396681138466,"sku":"OMRON-G3NA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-544.png?v=1790663955","url":"https:\/\/prosourcemro.com\/products\/omron-g3na-solid-state-relay-hockey-puck-5-90a-240-480vacdc-ul-csa-tuv","provider":"ProSource MRO","version":"1.0","type":"link"}