{"product_id":"omron-k2cm-motor-protective-relay-current-reverse-phase-inverse-2160a-100440vac","title":"Omron K2CM Motor Protective Relay (Current Reverse-phase, Inverse, 2~160A, 100~440VAC)","description":"\u003cp class=\"ps-intro\"\u003eSolid-state Relay Enables Choice of Three Operating Functions (Overcurrent, Openphase, and Reverse-phase).\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eMotor Protective Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection\u003c\/th\u003e\n\u003ctd\u003eCurrent reverse-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTrip Characteristic\u003c\/th\u003e\n\u003ctd\u003eInverse time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-1LS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 2~8A 100\/110\/120 VAC Manual | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 2~8A | Voltage: 100\/110\/120 VAC | Reset: Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 8~26A 100\/110\/120 VAC Manual | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 8~26A | Voltage: 100\/110\/120 VAC | Reset: Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 20~65A 100\/110\/120 VAC Manual | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 20~65A | Voltage: 100\/110\/120 VAC | Reset: Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 50~160A 100\/110\/120 VAC Manual | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 50~160A | Voltage: 100\/110\/120 VAC | Reset: Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-2LS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 2~8A 200\/220\/240 VAC Manual | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 2~8A | Voltage: 200\/220\/240 VAC | Reset: Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 8~26A 200\/220\/240 VAC Manual | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 8~26A | Voltage: 200\/220\/240 VAC | Reset: Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 20~65A 200\/220\/240 VAC Manual | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 20~65A | Voltage: 200\/220\/240 VAC | Reset: Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 50~160A 200\/220\/240 VAC Manual | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 50~160A | Voltage: 200\/220\/240 VAC | Reset: Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 8~26A 400\/440 VAC Manual | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 8~26A | Voltage: 400\/440 VAC | Reset: Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 20~65A 400\/440 VAC Manual | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 20~65A | Voltage: 400\/440 VAC | Reset: Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 50~160A 400\/440 VAC Manual | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 50~160A | Voltage: 400\/440 VAC | Reset: Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-1LSA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 2~8A 100\/110\/120 VAC Automatic | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 2~8A | Voltage: 100\/110\/120 VAC | Reset: Automatic | Note: Manual resetting required for reverse-phase detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-1LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 8~26A 100\/110\/120 VAC Automatic | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 8~26A | Voltage: 100\/110\/120 VAC | Reset: Automatic | Note: Manual resetting required for reverse-phase detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-1MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 20~65A 100\/110\/120 VAC Automatic | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 20~65A | Voltage: 100\/110\/120 VAC | Reset: Automatic | Note: Manual resetting required for reverse-phase detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-1HA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 50~160A 100\/110\/120 VAC Automatic | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 50~160A | Voltage: 100\/110\/120 VAC | Reset: Automatic | Note: Manual resetting required for reverse-phase detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-2LSA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 2~8A 200\/220\/240 VAC Automatic | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 2~8A | Voltage: 200\/220\/240 VAC | Reset: Automatic | Note: Manual resetting required for reverse-phase detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-2LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 8~26A 200\/220\/240 VAC Automatic | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 8~26A | Voltage: 200\/220\/240 VAC | Reset: Automatic | Note: Manual resetting required for reverse-phase detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-2MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 20~65A 200\/220\/240 VAC Automatic | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 20~65A | Voltage: 200\/220\/240 VAC | Reset: Automatic | Note: Manual resetting required for reverse-phase detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-2HA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 50~160A 200\/220\/240 VAC Automatic | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 50~160A | Voltage: 200\/220\/240 VAC | Reset: Automatic | Note: Manual resetting required for reverse-phase detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-4LA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 8~26A 400\/440 VAC Automatic | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 8~26A | Voltage: 400\/440 VAC | Reset: Automatic | Note: Manual resetting required for reverse-phase detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-4MA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 20~65A 400\/440 VAC Automatic | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 20~65A | Voltage: 400\/440 VAC | Reset: Automatic | Note: Manual resetting required for reverse-phase detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK2CM-4HA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eK2CM Current Rev-phase Inverse 50~160A 400\/440 VAC Automatic | Type: Motor Protective Relay | Detection: Current reverse-phase | Trip Characteristic: Inverse time | Current Range: 50~160A | Voltage: 400\/440 VAC | Reset: Automatic | Note: Manual resetting required for reverse-phase detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":67396667932962,"sku":"OMRON-K2CM-C-INV","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/001-445_aefdbfd7-a205-4534-bf79-7a1841f08e9b.png?v=1790663705","url":"https:\/\/prosourcemro.com\/products\/omron-k2cm-motor-protective-relay-current-reverse-phase-inverse-2160a-100440vac","provider":"ProSource MRO","version":"1.0","type":"link"}