{"product_id":"siemens-sentron-3wl10-etu-communication-accessories","title":"Siemens SENTRON 3WL10 ETU Trip Units, Rating Plugs \u0026 COM Modules","description":"\u003cp class=\"ps-intro\"\u003eElectronic trip units, metering functions, rating plugs, CB bus communication and I\/O modules and test devices for SENTRON 3WL10 air circuit breakers.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eETU320, ETU350, ETU360, ETU650 and ETU660 electronic trip units\u003c\/li\u003e\n\u003cli\u003eMF Basic \/ MF Advanced metering functions and voltage tap cable sets\u003c\/li\u003e\n\u003cli\u003eRating plugs 400 A to 1250 A, incl. L = OFF and Rc versions\u003c\/li\u003e\n\u003cli\u003eCOM040\/041\/042\/043 communications modules, IOM300\/IOM040 I\/O modules, COM ACT and Breaker Connect modules\u003c\/li\u003e\n\u003cli\u003eTD310 test device, TD410\/TD420 Breaker Data Adapters, current transformers and RR magnets\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct line\u003c\/th\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct family\u003c\/th\u003e\n\u003ctd\u003eSENTRON 3WL10 air circuit breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory group\u003c\/th\u003e\n\u003ctd\u003eETU, metering and communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eAir circuit breaker accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrdering\u003c\/th\u003e\n\u003ctd\u003eQuote on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog LV 10 · 2026, p. 165-167\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-5AA00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Electronic trip unit (ETU) | Version: ETU320 LIN, rotary coding switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9012-5AA00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Electronic trip unit (ETU) | Version: ETU350 LSIN, rotary coding switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9012-7AA00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Electronic trip unit (ETU) | Version: ETU360 LSING, rotary coding switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9017-5AA00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Electronic trip unit (ETU) | Version: ETU650 LSIN, display, COM\/metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9017-7AA00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Electronic trip unit (ETU) | Version: ETU660 LSING, display, COM\/metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Metering function ETU650\/660 | Version: MF Basic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Metering function ETU650\/660 | Version: MF Advanced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT08\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Metering function ETU650\/660 | Version: Voltage tap cables, 4P N right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT75\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Metering function ETU650\/660 | Version: Voltage tap cables, 4P N left, top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT76\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Metering function ETU650\/660 | Version: Voltage tap cables, 4P N left, bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT72\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Metering function ETU650\/660 | Version: Voltage tap cables, 3-pole, top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT73\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Metering function ETU650\/660 | Version: Voltage tap cables, 3-pole, bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AA30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: External N-conductor CT | Version: ETU320-ETU660, 3-pole CB only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0GF30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Transformer neutral point CT | Version: ETU660, Gret 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0GF31\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Transformer neutral point CT | Version: ETU660, Gret 250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0RC30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Summation CT Rc-CT | Version: ETU660, ext. residual current metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AK03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Remote reset magnet RR | Version: ETU320-ETU660 | Voltage: 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AK05\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Remote reset magnet RR | Version: ETU320-ETU660 | Voltage: 110 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AK06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Remote reset magnet RR | Version: ETU320-ETU660 | Voltage: 250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT38\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Spare battery for ETU | Version: ETU320, ETU350, ETU360, ETU650, ETU660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AA53\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: ETU320-ETU660, setting In | Rating: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AA55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: ETU320-ETU660, setting In | Rating: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AA56\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: ETU320-ETU660, setting In | Rating: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AA57\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: ETU320-ETU660, setting In | Rating: 1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AA58\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: ETU320-ETU660, setting In | Rating: 1250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0LF53\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: ETU 6-series, L = OFF | Rating: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0LF55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: ETU 6-series, L = OFF | Rating: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0LF56\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: ETU 6-series, L = OFF | Rating: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0LF57\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: ETU 6-series, L = OFF | Rating: 1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0LF58\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: ETU 6-series, L = OFF | Rating: 1250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0RC53\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: Rc plug ETU660, residual current | Rating: 400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0RC55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: Rc plug ETU660, residual current | Rating: 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0RC56\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: Rc plug ETU660, residual current | Rating: 800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0RC58\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Rating plug | Version: Rc plug ETU660, residual current | Rating: 1250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: CB bus communications module | Version: COM040 PROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: CB bus communications module | Version: COM041 PROFINET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: CB bus communications module | Version: COM043 Modbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT17\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: CB bus communications module | Version: COM042 Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: IOM300 external I\/O module | Version: ETU 6-series, DIN rail, 11 DI \/ 10 DO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: IOM040 internal I\/O module | Version: ETU 6-series, 2 DI \/ 2 DO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Actuator module COM ACT | Version: ETU 6-series, remote ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Breaker Connect module | Voltage: 110 … 240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT07\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Breaker Connect module | Voltage: 24 … 48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT11\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: COM signaling switch | Version: Ready-to-close COM RTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: COM signaling switch | Version: Position signaling COM PSS (withdr.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Test device \/ Breaker Data Adapter | Version: TD310 test device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Test device \/ Breaker Data Adapter | Version: TD410 Breaker Data Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3VW9011-0AT33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory: Test device \/ Breaker Data Adapter | Version: TD420 test device + data adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67535318516002,"sku":"3VW9011-5AA00","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/siemens-sentron-3wl10-etu-communication-accessories.jpg?v=1792150078","url":"https:\/\/prosourcemro.com\/products\/siemens-sentron-3wl10-etu-communication-accessories","provider":"ProSource MRO","version":"1.0","type":"link"}