{"product_id":"siemens-sentron-5sm2-rc-units-3-pole","title":"Siemens SENTRON 5SM2 RC Units 3-pole (Type A, AC)","description":"\u003cp class=\"ps-intro\"\u003eSiemens 5SM2 3-pole RC units for assembly with 5SY, 5SL4 or 5SP4 miniature circuit breakers to form a residual current operated circuit breaker.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eAdd-on RC units for 5SY, 5SL4 and 5SP4 miniature circuit breakers (B and C characteristics for 5SP4)\u003c\/li\u003e\n\u003cli\u003eTypes A, AC; instantaneous, super resistant [K], selective [S] and SIGRES versions\u003c\/li\u003e\n\u003cli\u003eRated residual currents from 10 mA to 1000 mA; rated current ranges 0.3 … 40 A, 0.3 … 63 A and 80 … 100 A\u003c\/li\u003e\n\u003cli\u003eCombinable with auxiliary switches, fault signal contacts, shunt trips and undervoltage releases\u003c\/li\u003e\n\u003cli\u003eNot suitable for use with 5SY5 (and type A\/F not with 5SY8) miniature circuit breakers\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eSENTRON 5SM2 RC unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting width\u003c\/th\u003e\n\u003ctd\u003e3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-25 … +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog LV 10 · 2026, p. 4\/36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2332-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Instantaneous | Type: A | IΔn: 30 mA | In: 0.3 … 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2332-6KK01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Super resistant [K] | Type: A | IΔn: 30 mA | In: 0.3 … 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2333-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SL4 | Version: Instantaneous | Type: A | IΔn: 30 mA | In: 0.3 … 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2335-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Instantaneous | Type: A | IΔn: 30 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2335-6KK01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Super resistant [K] | Type: A | IΔn: 30 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2336-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SL4 | Version: Instantaneous | Type: A | IΔn: 30 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2435-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Instantaneous | Type: A | IΔn: 100 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2632-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Instantaneous | Type: A | IΔn: 300 mA | In: 0.3 … 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2633-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SL4 | Version: Instantaneous | Type: A | IΔn: 300 mA | In: 0.3 … 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2635-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Instantaneous | Type: A | IΔn: 300 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2635-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Selective [S] | Type: A | IΔn: 300 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2636-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SL4 | Version: Instantaneous | Type: A | IΔn: 300 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2636-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SL4 | Version: Selective [S] | Type: A | IΔn: 300 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2735-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Instantaneous | Type: A | IΔn: 500 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2735-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Selective [S] | Type: A | IΔn: 500 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2832-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Selective [S] | Type: A | IΔn: 1000 mA | In: 0.3 … 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2835-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Selective [S] | Type: A | IΔn: 1000 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2332-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Instantaneous | Type: AC | IΔn: 30 mA | In: 0.3 … 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2333-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SL4 | Version: Instantaneous | Type: AC | IΔn: 30 mA | In: 0.3 … 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2335-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Instantaneous | Type: AC | IΔn: 30 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2336-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SL4 | Version: Instantaneous | Type: AC | IΔn: 30 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2632-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Instantaneous | Type: AC | IΔn: 300 mA | In: 0.3 … 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2633-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SL4 | Version: Instantaneous | Type: AC | IΔn: 300 mA | In: 0.3 … 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2635-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Instantaneous | Type: AC | IΔn: 300 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2636-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SL4 | Version: Instantaneous | Type: AC | IΔn: 300 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SM2735-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor MCB: 5SY | Version: Instantaneous | Type: AC | IΔn: 500 mA | In: 0.3 … 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67535324774690,"sku":"5SM2332-6","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/siemens-sentron-5sm2-rc-units-3-pole.jpg?v=1792150079","url":"https:\/\/prosourcemro.com\/products\/siemens-sentron-5sm2-rc-units-3-pole","provider":"ProSource MRO","version":"1.0","type":"link"}