{"product_id":"siemens-sentron-5st36-standard-busbars-fixed-lengths","title":"Siemens SENTRON 5ST36 Standard Busbars, Fixed Lengths","description":"\u003cp class=\"ps-intro\"\u003eSENTRON 5ST36 standard pin busbars in fixed lengths (cannot be cut) for connecting miniature circuit breakers, also with mounted AS\/FC or line-side RCCB.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eFixed lengths, cannot be cut, for 1-, 2-, 3- and 4-phase systems\u003c\/li\u003e\n\u003cli\u003eConductor cross-sections 10 mm2 and 16 mm2\u003c\/li\u003e\n\u003cli\u003eVersions for MCBs with mounted auxiliary switch or fault signal contact (9 mm offset)\u003c\/li\u003e\n\u003cli\u003eVersions for MCB groups with 3P+N RCCB (N right or N left)\u003c\/li\u003e\n\u003cli\u003eMax. busbar current per phase 63\/80 A (end infeed) or 100\/130 A (center infeed)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct line\u003c\/th\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eFixed lengths, cannot be cut\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePin spacing\u003c\/th\u003e\n\u003ctd\u003e1 MW = 18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. busbar current (end infeed)\u003c\/th\u003e\n\u003ctd\u003e63 A (10 mm2), 80 A (16 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. busbar current (center infeed)\u003c\/th\u003e\n\u003ctd\u003e100 A (10 mm2), 130 A (16 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog LV 10 · 2026, p. 336-339\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3600\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 1-phase | Application: 2 MCBs 1P | No. of MW: 2 MW | Length: 33 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3630\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 1-phase | Application: 2 MCBs 1P | No. of MW: 2 MW | Length: 33 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3601\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 1-phase | Application: 6 MCBs 1P | No. of MW: 6 MW | Length: 105 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3631\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 1-phase | Application: 6 MCBs 1P | No. of MW: 6 MW | Length: 105 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3602\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 1-phase | Application: 12 MCBs 1P | No. of MW: 12 MW | Length: 212 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3632\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 1-phase | Application: 12 MCBs 1P | No. of MW: 12 MW | Length: 212 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3606\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 2-phase\/1-phase + N | Application: 2 MCBs (2P\/1P+N) | No. of MW: 4 MW | Length: 76 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3636\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 2-phase\/1-phase + N | Application: 2 MCBs (2P\/1P+N) | No. of MW: 4 MW | Length: 76 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3607\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 2-phase\/1-phase + N | Application: 3 MCBs (2P\/1P+N) | No. of MW: 6 MW | Length: 105 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3637\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 2-phase\/1-phase + N | Application: 3 MCBs (2P\/1P+N) | No. of MW: 6 MW | Length: 105 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3608\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 2-phase\/1-phase + N | Application: 6 MCBs (2P\/1P+N) | No. of MW: 12 MW | Length: 210 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3638\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 2-phase\/1-phase + N | Application: 6 MCBs (2P\/1P+N) | No. of MW: 12 MW | Length: 210 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3613\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 2 MCBs 3P | No. of MW: 6 MW | Length: 102 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3643\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 2 MCBs 3P | No. of MW: 6 MW | Length: 102 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3614\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 3 MCBs 3P | No. of MW: 9 MW | Length: 157.5 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3644\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 3 MCBs 3P | No. of MW: 9 MW | Length: 157.5 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3615\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 4 MCBs 3P | No. of MW: 12 MW | Length: 210 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3645\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 4 MCBs 3P | No. of MW: 12 MW | Length: 210 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3613-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 14 MCBs 1P | No. of MW: 14 MW | Length: 250 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3621\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 4-phase\/3-phase + N | Application: 2 MCBs (4P\/3P+N) | No. of MW: 8 MW | Length: 138 mm\/140 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3651\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 4-phase\/3-phase + N | Application: 2 MCBs (4P\/3P+N) | No. of MW: 8 MW | Length: 138 mm\/140 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3622\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 4-phase\/3-phase + N | Application: 3 MCBs (4P\/3P+N) | No. of MW: 12 MW | Length: 210 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3652\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 4-phase\/3-phase + N | Application: 3 MCBs (4P\/3P+N) | No. of MW: 12 MW | Length: 210 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3623\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 4-phase\/3-phase + N | Application: 6 MCBs 1P+N | No. of MW: 12 MW | Length: 210 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3653\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 4-phase\/3-phase + N | Application: 6 MCBs 1P+N | No. of MW: 12 MW | Length: 210 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3623-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 4-phase\/3-phase + N | Application: 7 MCBs 1P+N | No. of MW: 14 MW | Length: 248 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3603\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 1-phase | Application: 2 MCBs 1P with AS\/FC | No. of MW: 2 MW | Length: 40 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3633\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 1-phase | Application: 2 MCBs 1P with AS\/FC | No. of MW: 2 MW | Length: 40 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3604\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 1-phase | Application: 6 MCBs 1P with AS\/FC | No. of MW: 6 MW | Length: 158 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3634\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 1-phase | Application: 6 MCBs 1P with AS\/FC | No. of MW: 6 MW | Length: 158 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3605\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 1-phase | Application: 9 MCBs 1P with AS\/FC | No. of MW: 9 MW | Length: 237 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3635\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 1-phase | Application: 9 MCBs 1P with AS\/FC | No. of MW: 9 MW | Length: 237 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3610\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 2-phase\/1-phase + N | Application: 2 MCBs (2P\/1P+N) with AS\/FC | No. of MW: 4 MW | Length: 76 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3640\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 2-phase\/1-phase + N | Application: 2 MCBs (2P\/1P+N) with AS\/FC | No. of MW: 4 MW | Length: 76 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3611\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 2-phase\/1-phase + N | Application: 3 MCBs (2P\/1P+N) with AS\/FC | No. of MW: 6 MW | Length: 121 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3641\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 2-phase\/1-phase + N | Application: 3 MCBs (2P\/1P+N) with AS\/FC | No. of MW: 6 MW | Length: 121 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3612\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 2-phase\/1-phase + N | Application: 5 MCBs (2P\/1P+N) with AS\/FC | No. of MW: 10 MW | Length: 210 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3642\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 2-phase\/1-phase + N | Application: 5 MCBs (2P\/1P+N) with AS\/FC | No. of MW: 10 MW | Length: 210 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3616\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 2 MCBs 3P with AS\/FC | No. of MW: 6 MW | Length: 115 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3646\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 2 MCBs 3P with AS\/FC | No. of MW: 6 MW | Length: 115 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3617\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 4 MCBs 3P with AS\/FC | No. of MW: 12 MW | Length: 237 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3647\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 4 MCBs 3P with AS\/FC | No. of MW: 12 MW | Length: 237 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3618\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 6 MCBs 1P with AS\/FC | No. of MW: 9 MW | Length: 156 mm\/158 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3648\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 6 MCBs 1P with AS\/FC | No. of MW: 9 MW | Length: 156 mm\/158 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3620\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 9 MCBs 1P with AS\/FC | No. of MW: 12 MW | Length: 227 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3650\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 9 MCBs 1P with AS\/FC | No. of MW: 12 MW | Length: 227 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3624-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 6 MCBs 1P + RCCB 3P+N (or alt. layout) | No. of MW: 10 MW | Length: 176 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3624\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 8 MCBs 1P + 1 RCCB 3P+N, N right | No. of MW: 12 MW | Length: 210 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3654\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 8 MCBs 1P + 1 RCCB 3P+N, N right | No. of MW: 12 MW | Length: 210 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3624-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 10 MCBs 1P + RCCB 3P+N (or alt. layout) | No. of MW: 14 MW | Length: 249 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3667\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 8 MCBs 1P + 1 RCCB 3P+N, N left | No. of MW: 11 MW | Length: 192 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3668\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 3-phase | Application: 8 MCBs 1P + 1 RCCB 3P+N, N left | No. of MW: 11 MW | Length: 192 mm | Cross-section: 16 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5ST3625-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhases: 4-phase\/3-phase + N | Application: 1 RCCB 3P+N + 5 MCBs 1P+N (2 MW) | No. of MW: 14 MW | Length: 248 mm | Cross-section: 10 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67535321530658,"sku":"5ST3600","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/siemens-sentron-5st36-standard-busbars-fixed-lengths.jpg?v=1792150078","url":"https:\/\/prosourcemro.com\/products\/siemens-sentron-5st36-standard-busbars-fixed-lengths","provider":"ProSource MRO","version":"1.0","type":"link"}