{"product_id":"siemens-sentron-5sy4-miniature-circuit-breakers-10ka","title":"Siemens SENTRON 5SY4 Miniature Circuit Breakers 10 kA (A, B, C, D)","description":"\u003cp class=\"ps-intro\"\u003eSENTRON 5SY4 miniature circuit breakers with 10 kA breaking capacity for advanced applications in buildings and industry.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRated currents 0.3 to 80 A, characteristics A, B, C and D\u003c\/li\u003e\n\u003cli\u003eVersions 1P, 1P+N, 2P, 3P, 3P+N and 4P\u003c\/li\u003e\n\u003cli\u003eCombinable with AS, FC, AS+FC, shunt trips, undervoltage releases and RCA\u003c\/li\u003e\n\u003cli\u003eArc fault detection unit 5SM6 mountable on 1P+N versions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct line\u003c\/th\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated short-circuit breaking capacity\u003c\/th\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60898-1, IEC\/EN 60947-2, UL 1077\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessories\u003c\/th\u003e\n\u003ctd\u003eAS, FC, ST, UR, RCA, AFDD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog LV 10 · 2026, p. 296-297\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4114-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.3 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4114-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.3 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4514-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.3 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4514-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.3 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4214-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.3 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4214-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.3 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4105-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4105-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4105-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4505-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4505-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4205-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4205-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4205-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4101-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4101-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4101-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4101-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4501-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4501-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4501-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4201-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4201-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4201-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4201-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4115-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4115-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4115-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4115-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4515-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4515-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 1P+N | Characteristic: B | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4515-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4515-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4215-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4215-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4215-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4215-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4102-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4102-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4102-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4102-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4502-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4502-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4502-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4202-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4202-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4202-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4202-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4103-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4103-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4103-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4103-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4503-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4503-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4503-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4203-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4203-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4203-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4203-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4104-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4104-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4104-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4104-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4504-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4504-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 1P+N | Characteristic: B | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4504-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4504-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4204-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4204-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4204-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4204-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4111-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 5 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4211-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 5 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4106-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4106-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4106-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4106-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4506-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4506-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 1P+N | Characteristic: B | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4506-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4506-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4206-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4206-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4206-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4206-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4108-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4108-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4108-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4108-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4508-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4508-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4508-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4208-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4208-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4208-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4208-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4110-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4110-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4110-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4110-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4510-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4510-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 1P+N | Characteristic: B | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4510-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4510-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4210-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4210-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4210-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4210-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4113-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4113-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4113-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4113-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4513-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4513-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 1P+N | Characteristic: B | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4513-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4513-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4213-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4213-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4213-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4213-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4118-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 15 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4218-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 15 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4116-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4116-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4116-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4116-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4516-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4516-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 1P+N | Characteristic: B | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4516-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4516-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4216-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4216-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4216-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4216-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4120-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4120-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4120-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4120-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4520-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4520-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 1P+N | Characteristic: B | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4520-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4520-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4220-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4220-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4220-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4220-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4125-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4125-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4125-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4125-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4525-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4525-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 1P+N | Characteristic: B | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4525-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4525-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4225-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4225-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4225-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4225-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4130-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 30 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4230-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 30 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4132-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4132-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4132-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4132-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4532-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4532-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 1P+N | Characteristic: B | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4532-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4532-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4232-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4232-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4232-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4232-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4135-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 35 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4235-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 35 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4140-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4140-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4140-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4140-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4540-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4540-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 1P+N | Characteristic: B | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4540-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4540-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4240-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4240-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4240-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4240-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4145-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 45 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4245-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 45 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4150-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4150-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4150-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4150-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4550-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4550-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 1P+N | Characteristic: B | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4550-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4550-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4250-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4250-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4250-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4250-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4160-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 60 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4260-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 60 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4163-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 1P | Characteristic: A | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4163-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4163-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4163-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 1P | Characteristic: D | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4563-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 1P+N | Characteristic: A | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4563-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 1P+N | Characteristic: B | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4563-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4563-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 1P+N | Characteristic: D | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4263-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 2P | Characteristic: A | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4263-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4263-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4263-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 2P | Characteristic: D | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4180-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 80 A | Poles: 1P | Characteristic: B | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4180-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 80 A | Poles: 1P | Characteristic: C | Rated voltage: 230\/400 V AC | Width: 1 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4580-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 80 A | Poles: 1P+N | Characteristic: C | Rated voltage: 230 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4280-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 80 A | Poles: 2P | Characteristic: B | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4280-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 80 A | Poles: 2P | Characteristic: C | Rated voltage: 400 V AC | Width: 2 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4314-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.3 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4314-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.3 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4614-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.3 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4614-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.3 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4414-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.3 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4414-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.3 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4305-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4305-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4305-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4605-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4605-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4405-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4405-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 0.5 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4301-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4301-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4301-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4301-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4601-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4601-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4601-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4401-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4401-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4401-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4315-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4315-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4315-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4315-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4615-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4615-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4615-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4415-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4415-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4415-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 1.6 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4302-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4302-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4302-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4302-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4602-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4602-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4602-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4402-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4402-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4402-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 2 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4303-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4303-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4303-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4303-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4603-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4603-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4603-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4403-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4403-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4403-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 3 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4304-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4304-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4304-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4304-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4604-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4604-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4604-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4404-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4404-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4404-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 4 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4311-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 5 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4306-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4306-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4306-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4306-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4606-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4606-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 3P+N | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4606-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4606-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4406-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4406-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 4P | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4406-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4406-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 6 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4308-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4308-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4308-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4308-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4608-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4608-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4608-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4408-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4408-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4408-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 8 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4310-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4310-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4310-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4310-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4610-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4610-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 3P+N | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4610-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4610-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4410-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4410-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 4P | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4410-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4410-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 10 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4313-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4313-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4313-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4313-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4613-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4613-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 3P+N | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4613-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4613-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4413-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4413-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 4P | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4413-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4413-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 13 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4318-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 15 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4316-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4316-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4316-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4316-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4616-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4616-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 3P+N | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4616-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4616-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4416-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4416-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 4P | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4416-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4416-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 16 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4320-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4320-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4320-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4320-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4620-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4620-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 3P+N | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4620-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4620-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4420-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4420-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 4P | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4420-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4420-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 20 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4325-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4325-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4325-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4325-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4625-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4625-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 3P+N | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4625-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4625-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4425-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4425-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 4P | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4425-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4425-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 25 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4330-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 30 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4332-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4332-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4332-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4332-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4632-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4632-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 3P+N | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4632-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4632-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4432-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4432-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 4P | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4432-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4432-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 32 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4335-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 35 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4340-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4340-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4340-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4340-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4640-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4640-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 3P+N | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4640-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4640-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4440-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4440-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 4P | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4440-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4440-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 40 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4345-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 45 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4350-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4350-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4350-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4350-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4650-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4650-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 3P+N | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4650-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4650-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4450-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4450-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 4P | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4450-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4450-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 50 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4360-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 60 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4363-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 3P | Characteristic: A | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4363-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4363-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4363-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 3P | Characteristic: D | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4663-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 3P+N | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4663-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 3P+N | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4663-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4663-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 3P+N | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4463-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 4P | Characteristic: A | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4463-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 4P | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4463-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4463-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 63 A | Poles: 4P | Characteristic: D | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4380-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 80 A | Poles: 3P | Characteristic: B | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4380-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 80 A | Poles: 3P | Characteristic: C | Rated voltage: 400 V AC | Width: 3 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4680-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 80 A | Poles: 3P+N | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4480-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 80 A | Poles: 4P | Characteristic: B | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SY4480-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated current: 80 A | Poles: 4P | Characteristic: C | Rated voltage: 400 V AC | Width: 4 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67535320351010,"sku":"5SY4114-7","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/siemens-sentron-5sy4-miniature-circuit-breakers-10ka.jpg?v=1792150079","url":"https:\/\/prosourcemro.com\/products\/siemens-sentron-5sy4-miniature-circuit-breakers-10ka","provider":"ProSource MRO","version":"1.0","type":"link"}