{"product_id":"siemens-simatic-et200sp-motor-starters-3rk1308","title":"Siemens SIMATIC ET 200SP Motor Starters 3RK1308 (0.1-12 A)","description":"\u003cp class=\"ps-intro\"\u003eSIMATIC ET 200SP hybrid motor starters for direct-on-line and reversing operation, also as fail-safe versions, integrated in the ET 200SP I\/O system.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDirect-on-line, reversing, fail-safe DOL and fail-safe reversing versions\u003c\/li\u003e\n\u003cli\u003eOverload setting ranges from 0.1-0.4 A to 4-12 A\u003c\/li\u003e\n\u003cli\u003eMax. current-carrying capacity on starting up to 120 A\u003c\/li\u003e\n\u003cli\u003e3DI\/LC submodule for local control with configurable digital inputs\u003c\/li\u003e\n\u003cli\u003eIE3\/IE4 ready\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct line\u003c\/th\u003e\n\u003ctd\u003eET 200SP motor starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem\u003c\/th\u003e\n\u003ctd\u003eSIMATIC ET 200SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminals\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog chapter\u003c\/th\u003e\n\u003ctd\u003eIC 10 ch. 8: load feeders, motor starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003ctd\u003eMotor Starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog IC 10 · 2026, p. 832-833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0AA00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Overload setting: 0.1-0.4 A | Max starting current: 4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0AB00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Overload setting: 0.3-1 A | Max starting current: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0AC00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Overload setting: 0.9-3 A | Max starting current: 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0AD00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Overload setting: 2.8-9 A | Max starting current: 90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0AE00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Overload setting: 4-12 A | Max starting current: 120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0BA00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Overload setting: 0.1-0.4 A | Max starting current: 4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0BB00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Overload setting: 0.3-1 A | Max starting current: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0BC00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Overload setting: 0.9-3 A | Max starting current: 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0BD00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Overload setting: 2.8-9 A | Max starting current: 90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0BE00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Overload setting: 4-12 A | Max starting current: 120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0CA00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Overload setting: 0.1-0.4 A | Max starting current: 4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0CB00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Overload setting: 0.3-1 A | Max starting current: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0CC00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Overload setting: 0.9-3 A | Max starting current: 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0CD00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Overload setting: 2.8-9 A | Max starting current: 90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0CE00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Overload setting: 4-12 A | Max starting current: 120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0DA00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Overload setting: 0.1-0.4 A | Max starting current: 4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0DB00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Overload setting: 0.3-1 A | Max starting current: 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0DC00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Overload setting: 0.9-3 A | Max starting current: 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0DD00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Overload setting: 2.8-9 A | Max starting current: 90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1308-0DE00-0CP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Overload setting: 4-12 A | Max starting current: 120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RK1908-1AA00-0BP0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: 3DI\/LC submodule (local control) | Overload setting: -- | Max starting current: --\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67535294365986,"sku":"3RK1308-0AA00-0CP0","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/siemens-simatic-et200sp-motor-starters-3rk1308.jpg?v=1792150099","url":"https:\/\/prosourcemro.com\/products\/siemens-simatic-et200sp-motor-starters-3rk1308","provider":"ProSource MRO","version":"1.0","type":"link"}