{"product_id":"siemens-simotics-m-1fe2-synchronous-built-in-motors","title":"Siemens SIMOTICS M-1FE2 Synchronous Built-in Motors (High Torque)","description":"\u003cp class=\"ps-intro\"\u003eSIMOTICS M-1FE2 High Torque synchronous built-in motors (1FE218x), water-cooled, delivered as stator and rotor for SINAMICS S120.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eHigh Torque series with rated torque up to 1530 Nm\u003c\/li\u003e\n\u003cli\u003eRated speeds 500 to 1000 rpm, maximum speed up to 4200 rpm\u003c\/li\u003e\n\u003cli\u003eStator with or without cooling jacket, standard rotor sleeve\u003c\/li\u003e\n\u003cli\u003eWinding protection standard, full or universal\u003c\/li\u003e\n\u003cli\u003eFree cable ends 0.5 m or 1.5 m\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor type\u003c\/th\u003e\n\u003ctd\u003eSynchronous built-in motor (stator + rotor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eHigh Torque\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eWater cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e100 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotor\u003c\/th\u003e\n\u003ctd\u003eStandard rotor sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine voltage\u003c\/th\u003e\n\u003ctd\u003e400 V 3 AC, Active Line Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog D 21.4 · 2026, p. 858-859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LH53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 68 kW \/ 640 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2182-8LN53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 34 kW \/ 650 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LH53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 88 kW \/ 840 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2183-8LN53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 44.5 kW \/ 840 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LH53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 105 kW \/ 1000 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LK53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 85 kW \/ 1010 Nm \/ 800 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2184-8LN53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 53 kW \/ 1010 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LH53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 122 kW \/ 1160 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LL53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 87 kW \/ 1180 Nm \/ 700 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2185-8LN53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 62 kW \/ 1180 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LH53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 142 kW \/ 1350 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LM53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 86 kW \/ 1370 Nm \/ 600 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2186-8LN53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 72 kW \/ 1370 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LH53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 159 kW \/ 1510 Nm \/ 1000 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN10-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN10-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN11-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN11-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN12-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN12-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN13-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN13-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Standard, 2x Pt1000 | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN30-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN30-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN31-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN31-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN32-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN32-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN33-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN33-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Full, 2x Pt1000 + 3x PTC | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN50-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN50-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN51-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN51-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 0.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN52-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN52-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, large OD or no jacket | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN53-1AC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: Without cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1FE2187-8LN53-1CC1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRating: 80 kW \/ 1530 Nm \/ 500 rpm | Winding protection: Universal protection | Cable: 1.5 m, small outer diameter | Stator: With cooling jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67535315304738,"sku":"1FE2182-8LH10-1AC1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/siemens-simotics-m-1fe2-synchronous-built-in-motors.jpg?v=1792150123","url":"https:\/\/prosourcemro.com\/products\/siemens-simotics-m-1fe2-synchronous-built-in-motors","provider":"ProSource MRO","version":"1.0","type":"link"}