{"product_id":"siemens-sinamics-g120-output-reactors","title":"Siemens SINAMICS G120 Output Reactors (PM240-2, PM250)","description":"\u003cp class=\"ps-intro\"\u003eOutput reactors for SINAMICS G120 Power Modules that reduce voltage rise rates and current peaks and allow longer motor cables.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eReduce rate of voltage rise (dv\/dt) and current peaks at the motor\u003c\/li\u003e\n\u003cli\u003eAllow longer shielded\/unshielded motor cables\u003c\/li\u003e\n\u003cli\u003eVersions for PM240-2 (200-690 V) and PM250 (380-480 V)\u003c\/li\u003e\n\u003cli\u003ePartly supplied by Mdexx Magnetronic Devices; \"JTA:\" prefix is part of the Siemens order code\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct line\u003c\/th\u003e\n\u003ctd\u003eSINAMICS G120 standard converters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003ctd\u003eOutput reactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog section\u003c\/th\u003e\n\u003ctd\u003eLoad-side power components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003ctd\u003eReduces dv\/dt and current peaks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrefix JTA:\u003c\/th\u003e\n\u003ctd\u003eMdexx Magnetronic Devices (OEM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog D 31.1 · 2024\/10-2025, p. 237-238\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3000-2BE33-2AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: PM240-2 | Line voltage: 380-480 V 3 AC | Rated power (kW): 160 | Frame size: FSG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3000-2BE33-8AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: PM240-2 | Line voltage: 380-480 V 3 AC | Rated power (kW): 200 | Frame size: FSG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3000-2BE35-0AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: PM240-2 | Line voltage: 380-480 V 3 AC | Rated power (kW): 250 | Frame size: FSG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJTA:TEU2532-0FP00-4EA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: PM240-2 | Line voltage: 500-690 V 3 AC | Rated power (kW): 11-18.5 | Frame size: FSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJTA:TEU9932-0FP00-4EA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: PM240-2 | Line voltage: 500-690 V 3 AC | Rated power (kW): 22-37 | Frame size: FSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJTA:TEU9932-0FS00-0EA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: PM240-2 | Line voltage: 500-690 V 3 AC | Rated power (kW): 45-55 | Frame size: FSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJTA:TEU9932-1FC00-1BA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: PM240-2 | Line voltage: 500-690 V 3 AC | Rated power (kW): 75-90 | Frame size: FSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJTA:TEU9932-0FV00-1BA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: PM240-2 | Line voltage: 500-690 V 3 AC | Rated power (kW): 110-132 | Frame size: FSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJTA:TEU4732-0FA00-0BA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: PM240-2 | Line voltage: 500-690 V 3 AC | Rated power (kW): 160-250 | Frame size: FSG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3202-0AJ23-2CA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: PM250 | Line voltage: 380-480 V 3 AC | Rated power (kW): 7.5-15 | Frame size: FSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SE6400-3TC08-0ED0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: PM250 | Line voltage: 380-480 V 3 AC | Rated power (kW): 37 | Frame size: FSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SE6400-3TC15-4FD0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModule: PM250 | Line voltage: 380-480 V 3 AC | Rated power (kW): 75 | Frame size: FSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67534388035874,"sku":"6SL3000-2BE33-2AA0","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/siemens-sinamics-g120-output-reactors.jpg?v=1792131804","url":"https:\/\/prosourcemro.com\/products\/siemens-sinamics-g120-output-reactors","provider":"ProSource MRO","version":"1.0","type":"link"}