{"product_id":"siemens-sinamics-g120-pm240-2-power-modules-500-690v","title":"Siemens SINAMICS G120 PM240-2 Power Modules (500-690 V, 11-250 kW)","description":"\u003cp class=\"ps-intro\"\u003eSINAMICS G120 PM240-2 Power Modules for 500-690 V 3 AC line supplies, the power section of the modular G120 converter combined with a separate Control Unit.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eLow-overload (LO) and high-overload (HO) ratings for each frame size\u003c\/li\u003e\n\u003cli\u003eIntegrated braking chopper for connection of an external braking resistor\u003c\/li\u003e\n\u003cli\u003eVariants with or without integrated line filter\u003c\/li\u003e\n\u003cli\u003eSafety Integrated functions provided via the plugged Control Unit\u003c\/li\u003e\n\u003cli\u003eCombines with any CU230P-2, CU240E-2 or CU250S-2 Control Unit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct line\u003c\/th\u003e\n\u003ctd\u003eSINAMICS G120 standard converters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Module\u003c\/th\u003e\n\u003ctd\u003ePM240-2 standard variant, IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine voltage\u003c\/th\u003e\n\u003ctd\u003e500-690 V 3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking\u003c\/th\u003e\n\u003ctd\u003eIntegrated braking chopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog D 31.1 · 2024\/10-2025, p. 191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH21-4UL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 11 kW \/ 10 hp | Rated current IN: 14 A | Power (HO): 7.5 kW \/ 7.5 hp | Base-load current IH: 11 A | Frame size: FSD | Integrated line filter: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH21-4AL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 11 kW \/ 10 hp | Rated current IN: 14 A | Power (HO): 7.5 kW \/ 7.5 hp | Base-load current IH: 11 A | Frame size: FSD | Integrated line filter: Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH22-0UL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 15 kW \/ 15 hp | Rated current IN: 19 A | Power (HO): 11 kW \/ 10 hp | Base-load current IH: 14 A | Frame size: FSD | Integrated line filter: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH22-0AL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 15 kW \/ 15 hp | Rated current IN: 19 A | Power (HO): 11 kW \/ 10 hp | Base-load current IH: 14 A | Frame size: FSD | Integrated line filter: Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH22-3UL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 18.5 kW \/ 20 hp | Rated current IN: 23 A | Power (HO): 15 kW \/ 15 hp | Base-load current IH: 19 A | Frame size: FSD | Integrated line filter: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH22-3AL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 18.5 kW \/ 20 hp | Rated current IN: 23 A | Power (HO): 15 kW \/ 15 hp | Base-load current IH: 19 A | Frame size: FSD | Integrated line filter: Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH22-7UL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 22 kW \/ 25 hp | Rated current IN: 27 A | Power (HO): 18.5 kW \/ 20 hp | Base-load current IH: 23 A | Frame size: FSD | Integrated line filter: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH22-7AL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 22 kW \/ 25 hp | Rated current IN: 27 A | Power (HO): 18.5 kW \/ 20 hp | Base-load current IH: 23 A | Frame size: FSD | Integrated line filter: Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH23-5UL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 30 kW \/ 30 hp | Rated current IN: 35 A | Power (HO): 22 kW \/ 25 hp | Base-load current IH: 27 A | Frame size: FSD | Integrated line filter: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH23-5AL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 30 kW \/ 30 hp | Rated current IN: 35 A | Power (HO): 22 kW \/ 25 hp | Base-load current IH: 27 A | Frame size: FSD | Integrated line filter: Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH24-2UL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 37 kW \/ 40 hp | Rated current IN: 42 A | Power (HO): 30 kW \/ 30 hp | Base-load current IH: 35 A | Frame size: FSD | Integrated line filter: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH24-2AL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 37 kW \/ 40 hp | Rated current IN: 42 A | Power (HO): 30 kW \/ 30 hp | Base-load current IH: 35 A | Frame size: FSD | Integrated line filter: Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH25-2UL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 45 kW \/ 50 hp | Rated current IN: 52 A | Power (HO): 37 kW \/ 40 hp | Base-load current IH: 42 A | Frame size: FSE | Integrated line filter: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH25-2AL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 45 kW \/ 50 hp | Rated current IN: 52 A | Power (HO): 37 kW \/ 40 hp | Base-load current IH: 42 A | Frame size: FSE | Integrated line filter: Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH26-2UL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 55 kW \/ 60 hp | Rated current IN: 62 A | Power (HO): 45 kW \/ 50 hp | Base-load current IH: 52 A | Frame size: FSE | Integrated line filter: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH26-2AL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 55 kW \/ 60 hp | Rated current IN: 62 A | Power (HO): 45 kW \/ 50 hp | Base-load current IH: 52 A | Frame size: FSE | Integrated line filter: Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH28-0UL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 75 kW \/ 75 hp | Rated current IN: 80 A | Power (HO): 55 kW \/ 60 hp | Base-load current IH: 62 A | Frame size: FSF | Integrated line filter: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH28-0AL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 75 kW \/ 75 hp | Rated current IN: 80 A | Power (HO): 55 kW \/ 60 hp | Base-load current IH: 62 A | Frame size: FSF | Integrated line filter: Category C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH31-0UL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 90 kW \/ 100 hp | Rated current IN: 100 A | Power (HO): 75 kW \/ 75 hp | Base-load current IH: 80 A | Frame size: FSF | Integrated line filter: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH31-0AL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 90 kW \/ 100 hp | Rated current IN: 100 A | Power (HO): 75 kW \/ 75 hp | Base-load current IH: 80 A | Frame size: FSF | Integrated line filter: Category C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH31-2UL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 110 kW \/ 100 hp | Rated current IN: 115 A | Power (HO): 90 kW \/ 100 hp | Base-load current IH: 100 A | Frame size: FSF | Integrated line filter: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH31-2AL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 110 kW \/ 100 hp | Rated current IN: 115 A | Power (HO): 90 kW \/ 100 hp | Base-load current IH: 100 A | Frame size: FSF | Integrated line filter: Category C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH31-4UL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 132 kW \/ 125 hp | Rated current IN: 142 A | Power (HO): 110 kW \/ 100 hp | Base-load current IH: 115 A | Frame size: FSF | Integrated line filter: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH31-4AL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 132 kW \/ 125 hp | Rated current IN: 142 A | Power (HO): 110 kW \/ 100 hp | Base-load current IH: 115 A | Frame size: FSF | Integrated line filter: Category C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH31-7CL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 160 kW \/ 150 hp | Rated current IN: 171 A | Power (HO): 132 kW \/ 150 hp | Base-load current IH: 142 A | Frame size: FSG | Integrated line filter: Category C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH32-1CL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 200 kW \/ 200 hp | Rated current IN: 208 A | Power (HO): 160 kW \/ 150 hp | Base-load current IH: 171 A | Frame size: FSG | Integrated line filter: Category C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6SL3210-1PH32-5CL0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated power (LO): 250 kW \/ 250 hp | Rated current IN: 250 A | Power (HO): 200 kW \/ 200 hp | Base-load current IH: 208 A | Frame size: FSG | Integrated line filter: Category C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67534387544354,"sku":"6SL3210-1PH21-4UL0","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/siemens-sinamics-g120-pm240-2-power-modules-500-690v.jpg?v=1792131803","url":"https:\/\/prosourcemro.com\/products\/siemens-sinamics-g120-pm240-2-power-modules-500-690v","provider":"ProSource MRO","version":"1.0","type":"link"}