{"product_id":"siemens-siplus-power-supplies","title":"Siemens SIPLUS Power Supplies (Extended Temp. \/ Harsh Environment)","description":"\u003cp class=\"ps-intro\"\u003eSIPLUS versions of SITOP and SIMATIC power supplies for extended temperature ranges and exposure to environmental substances.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eBased on LOGO!Power, PSU8200, PSU100S\/300S, PSU200M and SIMATIC design units\u003c\/li\u003e\n\u003cli\u003eExtended temperature range and\/or exposure to environmental substances\u003c\/li\u003e\n\u003cli\u003eS7-1500 system power supplies for the backplane bus\u003c\/li\u003e\n\u003cli\u003eSIPLUS DC\/DC converter versions incl. PSU3400 uni\u003c\/li\u003e\n\u003cli\u003eRolling stock railway application variants\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct line\u003c\/th\u003e\n\u003ctd\u003eSIPLUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage\u003c\/th\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eDIN rail \/ SIMATIC rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003ctd\u003eDC Power Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog KT 10.1, p. 311-313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1337-8SB00-7AY0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: PSU8200 1-phase | Input: 120\/230 V AC | Output: 24 V DC \/ 40 A | Note: Ext. temp + env. substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1437-8SB00-7AY0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: PSU8200 3-phase | Input: 400-500 V 3 AC | Output: 24 V DC \/ 40 A | Note: Ext. temp + env. substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1334-2BA20-4AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: PSU100S | Input: 120\/230 V AC | Output: 24 V DC \/ 10 A | Note: Ext. temp + env. substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1433-2BA20-7AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: PSU300S 3-phase | Input: 400 ... 500 V 3 AC | Output: 24 V DC \/ 5 A | Note: Ext. temp + env. substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1434-2BA20-7AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: PSU300S 3-phase | Input: 400 ... 500 V 3 AC | Output: 24 V DC \/ 10 A | Note: Ext. temp + env. substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1436-2BA10-7AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: PSU300S 3-phase | Input: 400 ... 500 V 3 AC | Output: 24 V DC \/ 20 A | Note: Ext. temp + env. substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1333-3BA10-7AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: PSU200M 1\/2-phase | Input: 120-230\/230-500 V AC | Output: 24 V DC \/ 5 A | Note: Env. substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1334-3BA10-7AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: PSU200M 1\/2-phase | Input: 120-230\/230-500 V AC | Output: 24 V DC \/ 10 A | Note: Env. substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1305-1BA80-2AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: S7-300 PS 305 | Input: 24 ... 110 V DC | Output: 24 V DC \/ 2 A | Note: Ext. temp + env. substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1307-1EA01-7AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: S7-300 PS 307 | Input: 120\/230 V AC | Output: 24 V DC \/ 5 A | Note: Incl. connecting comb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1307-1KA02-7AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: S7-300 PS 307 | Input: 120\/230 V AC | Output: 24 V DC \/ 10 A | Note: Rolling stock railway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1931-2BA00-3AA0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: PS 24V\/0.375A DC\/DC | Input: 48 ... 220 V DC | Output: 24 V DC \/ 0.375 A | Note: Condensation permissible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6AG1332-0TA00-7AY0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBase: PSU3400 uni | Input: 230 V AC \/ 24 V DC | Output: 24 V DC \/ 2.5 A | Note: Conformal coating, -40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67534409564450,"sku":"6AG1337-8SB00-7AY0","price":0.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/prosourcemro.com\/products\/siemens-siplus-power-supplies","provider":"ProSource MRO","version":"1.0","type":"link"}