{"product_id":"siemens-sirius-3ra61-compact-dol-starters","title":"Siemens SIRIUS 3RA61 Compact Direct-on-Line Starters (0.1-32 A)","description":"\u003cp class=\"ps-intro\"\u003eSIRIUS 3RA61 compact starters integrate circuit breaker, contactor and electronic overload protection for direct-on-line starting in a 45 mm wide device.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eSetting ranges 0.1-0.4 A up to 8-32 A for motors 0.09 kW to 15 kW at 400 V\u003c\/li\u003e\n\u003cli\u003eRated short-circuit current 53 kA at 400 V, width 45 mm\u003c\/li\u003e\n\u003cli\u003eControl supply 24 V AC\/DC or 110-240 V AC\/DC\u003c\/li\u003e\n\u003cli\u003eVersions for DIN rail, 3RA6 infeed system and AS-i add-on module\u003c\/li\u003e\n\u003cli\u003eScrew or spring-loaded terminals; screw fixing with 3RA6940-0A adapters\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct line\u003c\/th\u003e\n\u003ctd\u003eSIRIUS 3RA6 compact starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated short-circuit current\u003c\/th\u003e\n\u003ctd\u003eIcs = 53 kA at 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload release\u003c\/th\u003e\n\u003ctd\u003eElectronic, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor readiness\u003c\/th\u003e\n\u003ctd\u003eIE3\/IE4 ready\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003ctd\u003eDirect-on-line starting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003ctd\u003eMotor Starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog IC 10 · 2026, p. 787-788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-0AB30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.09 kW | Overload setting: 0.1-0.4 A | Instantaneous release: 56 A | Version: Infeed\/AS-i, no main\/control terminals | Terminals: None | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-0BB30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.37 kW | Overload setting: 0.32-1.25 A | Instantaneous release: 56 A | Version: Infeed\/AS-i, no main\/control terminals | Terminals: None | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-0CB30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 1.5 kW | Overload setting: 1-4 A | Instantaneous release: 56 A | Version: Infeed\/AS-i, no main\/control terminals | Terminals: None | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-0DB30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 5.5 kW | Overload setting: 3-12 A | Instantaneous release: 168 A | Version: Infeed\/AS-i, no main\/control terminals | Terminals: None | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-0EB30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 15 kW | Overload setting: 8-32 A | Instantaneous release: 448 A | Version: Infeed\/AS-i, no main\/control terminals | Terminals: None | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1AB32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.09 kW | Overload setting: 0.1-0.4 A | Instantaneous release: 56 A | Version: Main + control terminals | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2AB32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.09 kW | Overload setting: 0.1-0.4 A | Instantaneous release: 56 A | Version: Main + control terminals | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1BB32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.37 kW | Overload setting: 0.32-1.25 A | Instantaneous release: 56 A | Version: Main + control terminals | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2BB32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.37 kW | Overload setting: 0.32-1.25 A | Instantaneous release: 56 A | Version: Main + control terminals | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1CB32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 1.5 kW | Overload setting: 1-4 A | Instantaneous release: 56 A | Version: Main + control terminals | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2CB32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 1.5 kW | Overload setting: 1-4 A | Instantaneous release: 56 A | Version: Main + control terminals | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1DB32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 5.5 kW | Overload setting: 3-12 A | Instantaneous release: 168 A | Version: Main + control terminals | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2DB32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 5.5 kW | Overload setting: 3-12 A | Instantaneous release: 168 A | Version: Main + control terminals | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1EB32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 15 kW | Overload setting: 8-32 A | Instantaneous release: 448 A | Version: Main + control terminals | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2EB32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 15 kW | Overload setting: 8-32 A | Instantaneous release: 448 A | Version: Main + control terminals | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1AB33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.09 kW | Overload setting: 0.1-0.4 A | Instantaneous release: 56 A | Version: Infeed, control terminals only | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2AB33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.09 kW | Overload setting: 0.1-0.4 A | Instantaneous release: 56 A | Version: Infeed, control terminals only | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1BB33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.37 kW | Overload setting: 0.32-1.25 A | Instantaneous release: 56 A | Version: Infeed, control terminals only | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2BB33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.37 kW | Overload setting: 0.32-1.25 A | Instantaneous release: 56 A | Version: Infeed, control terminals only | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1CB33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 1.5 kW | Overload setting: 1-4 A | Instantaneous release: 56 A | Version: Infeed, control terminals only | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2CB33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 1.5 kW | Overload setting: 1-4 A | Instantaneous release: 56 A | Version: Infeed, control terminals only | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1DB33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 5.5 kW | Overload setting: 3-12 A | Instantaneous release: 168 A | Version: Infeed, control terminals only | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2DB33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 5.5 kW | Overload setting: 3-12 A | Instantaneous release: 168 A | Version: Infeed, control terminals only | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1EB33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 15 kW | Overload setting: 8-32 A | Instantaneous release: 448 A | Version: Infeed, control terminals only | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2EB33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 15 kW | Overload setting: 8-32 A | Instantaneous release: 448 A | Version: Infeed, control terminals only | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1AB34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.09 kW | Overload setting: 0.1-0.4 A | Instantaneous release: 56 A | Version: AS-i, main terminals only | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1BB34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.37 kW | Overload setting: 0.32-1.25 A | Instantaneous release: 56 A | Version: AS-i, main terminals only | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2BB34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.37 kW | Overload setting: 0.32-1.25 A | Instantaneous release: 56 A | Version: AS-i, main terminals only | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1CB34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 1.5 kW | Overload setting: 1-4 A | Instantaneous release: 56 A | Version: AS-i, main terminals only | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2CB34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 1.5 kW | Overload setting: 1-4 A | Instantaneous release: 56 A | Version: AS-i, main terminals only | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1DB34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 5.5 kW | Overload setting: 3-12 A | Instantaneous release: 168 A | Version: AS-i, main terminals only | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2DB34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 5.5 kW | Overload setting: 3-12 A | Instantaneous release: 168 A | Version: AS-i, main terminals only | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1EB34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 15 kW | Overload setting: 8-32 A | Instantaneous release: 448 A | Version: AS-i, main terminals only | Terminals: Screw | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2EB34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 15 kW | Overload setting: 8-32 A | Instantaneous release: 448 A | Version: AS-i, main terminals only | Terminals: Spring-loaded | Control voltage: 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-0BP30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.37 kW | Overload setting: 0.32-1.25 A | Instantaneous release: 56 A | Version: Infeed\/AS-i, no main\/control terminals | Terminals: None | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-0CP30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 1.5 kW | Overload setting: 1-4 A | Instantaneous release: 56 A | Version: Infeed\/AS-i, no main\/control terminals | Terminals: None | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-0EP30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 15 kW | Overload setting: 8-32 A | Instantaneous release: 448 A | Version: Infeed\/AS-i, no main\/control terminals | Terminals: None | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1AP32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.09 kW | Overload setting: 0.1-0.4 A | Instantaneous release: 56 A | Version: Main + control terminals | Terminals: Screw | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2AP32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.09 kW | Overload setting: 0.1-0.4 A | Instantaneous release: 56 A | Version: Main + control terminals | Terminals: Spring-loaded | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1BP32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.37 kW | Overload setting: 0.32-1.25 A | Instantaneous release: 56 A | Version: Main + control terminals | Terminals: Screw | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2BP32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.37 kW | Overload setting: 0.32-1.25 A | Instantaneous release: 56 A | Version: Main + control terminals | Terminals: Spring-loaded | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1CP32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 1.5 kW | Overload setting: 1-4 A | Instantaneous release: 56 A | Version: Main + control terminals | Terminals: Screw | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2CP32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 1.5 kW | Overload setting: 1-4 A | Instantaneous release: 56 A | Version: Main + control terminals | Terminals: Spring-loaded | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1DP32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 5.5 kW | Overload setting: 3-12 A | Instantaneous release: 168 A | Version: Main + control terminals | Terminals: Screw | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2DP32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 5.5 kW | Overload setting: 3-12 A | Instantaneous release: 168 A | Version: Main + control terminals | Terminals: Spring-loaded | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1EP32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 15 kW | Overload setting: 8-32 A | Instantaneous release: 448 A | Version: Main + control terminals | Terminals: Screw | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2EP32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 15 kW | Overload setting: 8-32 A | Instantaneous release: 448 A | Version: Main + control terminals | Terminals: Spring-loaded | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1BP33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.37 kW | Overload setting: 0.32-1.25 A | Instantaneous release: 56 A | Version: Infeed, control terminals only | Terminals: Screw | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2BP33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 0.37 kW | Overload setting: 0.32-1.25 A | Instantaneous release: 56 A | Version: Infeed, control terminals only | Terminals: Spring-loaded | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1CP33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 1.5 kW | Overload setting: 1-4 A | Instantaneous release: 56 A | Version: Infeed, control terminals only | Terminals: Screw | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2CP33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 1.5 kW | Overload setting: 1-4 A | Instantaneous release: 56 A | Version: Infeed, control terminals only | Terminals: Spring-loaded | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1DP33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 5.5 kW | Overload setting: 3-12 A | Instantaneous release: 168 A | Version: Infeed, control terminals only | Terminals: Screw | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2DP33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 5.5 kW | Overload setting: 3-12 A | Instantaneous release: 168 A | Version: Infeed, control terminals only | Terminals: Spring-loaded | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-1EP33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 15 kW | Overload setting: 8-32 A | Instantaneous release: 448 A | Version: Infeed, control terminals only | Terminals: Screw | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RA6120-2EP33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor 400 V: 15 kW | Overload setting: 8-32 A | Instantaneous release: 448 A | Version: Infeed, control terminals only | Terminals: Spring-loaded | Control voltage: 110-240 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67535294038306,"sku":"3RA6120-0AB30","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/siemens-sirius-3ra61-compact-dol-starters.jpg?v=1792150147","url":"https:\/\/prosourcemro.com\/products\/siemens-sirius-3ra61-compact-dol-starters","provider":"ProSource MRO","version":"1.0","type":"link"}