{"product_id":"siemens-sirius-3rf33-solid-state-contactors","title":"Siemens SIRIUS 3RF33 Solid-State Contactors 1-Pole (6-80 A)","description":"\u003cp class=\"ps-intro\"\u003eSIRIUS 3RF33 1-pole solid-state contactors with integrated, optimally matched heat sink, ready to use for resistive and inductive loads.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eOperational current at AC-1 from 6 A to 80 A\u003c\/li\u003e\n\u003cli\u003eOperational voltage 24-230 V, 48-460 V or 48-600 V AC\u003c\/li\u003e\n\u003cli\u003eZero-point or instantaneous switching (AC-15 for valves)\u003c\/li\u003e\n\u003cli\u003eShort-circuit-proof versions with B miniature circuit breaker\u003c\/li\u003e\n\u003cli\u003eScrew, spring-loaded or ring cable lug connection\u003c\/li\u003e\n\u003cli\u003eGrounding via DIN rail or heat sink screw terminal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct line\u003c\/th\u003e\n\u003ctd\u003eSIRIUS 3RF33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003ctd\u003eSolid-state contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat sink\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog chapter\u003c\/th\u003e\n\u003ctd\u003e6 - Soft starters and solid-state switching devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog IC 10 · 2026, p. 571-576\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1AA12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 24-230 V AC | Control supply: 24 V AC\/DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1AA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1AA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1AA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1AA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1AA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1AA02-0KN0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point; low power | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1AA44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-460 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-460 V AC | Control supply: 24 V AC\/DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1AA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1AA44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 24 V AC\/DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1AA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1AA44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-460 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-460 V AC | Control supply: 24 V AC\/DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1AA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 48-460 V AC | Control supply: 24 V AC\/DC | Switching: Zero-point | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1AA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 48-460 V AC | Control supply: 24 V AC\/DC | Switching: Zero-point | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1AA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1AA04-0KN0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point; low power | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1DA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point; B-MCB-proof | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1DA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Zero-point; B-MCB-proof | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1DA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point; B-MCB-proof | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1DA44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 4-30 V DC | Switching: Zero-point; B-MCB-proof | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1DA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point; B-MCB-proof | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1DA44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-460 V AC | Control supply: 4-30 V DC | Switching: Zero-point; B-MCB-proof | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1DA04-0KN0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point; B-MCB-proof; low power | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1DA04-0KN0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point; B-MCB-proof; low power | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3306-1AA45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 6 A | Op voltage: 48-600 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Screw | Grounding: Plastic heat sink, none needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1AA45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-600 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1AA45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-600 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1AA65\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-600 V AC | Control supply: 110 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1AA45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-600 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1AA25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1AA45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 48-600 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1AA45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 48-600 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1AA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Zero-point; high blocking voltage | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1AA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Zero-point; high blocking voltage | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1AA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Zero-point; high blocking voltage | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1AA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Zero-point; high blocking voltage | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1AA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Zero-point; high blocking voltage | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1DA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; B-MCB-proof; high blocking | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-2AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-2AA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-2AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-2AA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-2DA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Zero-point; B-MCB-proof | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-2AA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-2AA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-2DA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point; B-MCB-proof | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-2DA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point; B-MCB-proof | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-2AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-2AA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Zero-point; high blocking voltage | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-2AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-2AA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Zero-point; high blocking voltage | Connection: Spring-loaded | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-3AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-3AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-3AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-3AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-3AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-3AA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3AA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3AA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3AA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-3AA44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-460 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-3AA44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-460 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-3AA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Ring cable lug | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-3AA44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 48-460 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-3AA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3AA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3AA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-3AA45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 48-600 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3AA45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A | Op voltage: 48-600 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3AA45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A | Op voltage: 48-600 V AC | Control supply: 4-30 V DC | Switching: Zero-point | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-3AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Ring cable lug | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-3AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Ring cable lug | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-3AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-3AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-3AA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Zero-point; high blocking voltage | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3AA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Zero-point; high blocking voltage | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3AA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Zero-point; high blocking voltage | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3AA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Zero-point; high blocking voltage | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1BA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A \/ 6 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1BA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A \/ 6 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1BA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A \/ 12 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1BA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A \/ 12 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1BA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A \/ 15 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1BA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A \/ 15 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1BA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A \/ 20 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1BA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A \/ 20 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1BA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A \/ 25 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1BA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A \/ 25 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-1BA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: -- \/ 27.5 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-1BA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: -- \/ -- | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-1BA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: -- \/ -- | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1BA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A \/ 6 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1BA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A \/ 6 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1BA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A \/ 12 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1BA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A \/ 12 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1BA44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A \/ 12 A | Op voltage: 48-460 V AC | Control supply: 4-30 V DC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1BA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A \/ 15 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1BA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A \/ 15 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1BA44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A \/ 15 A | Op voltage: 48-460 V AC | Control supply: 4-30 V DC | Switching: Instantaneous | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1BA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A \/ 20 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1BA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A \/ 20 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1BA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A \/ 25 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1BA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A \/ 25 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1BA44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A \/ 25 A | Op voltage: 48-460 V AC | Control supply: 4-30 V DC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-1BA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: -- \/ 27.5 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-1BA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: -- \/ 27.5 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-1BA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: -- \/ -- | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-1BA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: -- \/ -- | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1BA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A \/ 6 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Instantaneous; high blocking voltage | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3310-1BA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 10 A \/ 6 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Instantaneous; high blocking voltage | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1BA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A \/ 12 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Instantaneous; high blocking voltage | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3320-1BA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 20 A \/ 12 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Instantaneous; high blocking voltage | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1BA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A \/ 15 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Instantaneous; high blocking voltage | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3330-1BA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 30 A \/ 15 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Instantaneous; high blocking voltage | Connection: Screw | Grounding: DIN rail snap-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1BA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A \/ 20 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Instantaneous; high blocking voltage | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3340-1BA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 40 A \/ 20 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Instantaneous; high blocking voltage | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3350-1BA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 50 A \/ 25 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Instantaneous; high blocking voltage | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-1BA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: -- \/ 27.5 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Instantaneous; high blocking voltage | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-1BA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: -- \/ -- | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Instantaneous; high blocking voltage | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-1BA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: -- \/ -- | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Instantaneous; high blocking voltage | Connection: Screw | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3BA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A \/ 27.5 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3BA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A \/ 27.5 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3BA02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A \/ 27.5 A | Op voltage: 24-230 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3BA22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A \/ 27.5 A | Op voltage: 24-230 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3BA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A \/ 27.5 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3BA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A \/ 27.5 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3BA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A \/ 27.5 A | Op voltage: 48-460 V AC | Control supply: 24 V DC | Switching: Instantaneous | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3BA24\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A \/ 27.5 A | Op voltage: 48-460 V AC | Control supply: 110-230 V AC | Switching: Instantaneous | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3BA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A \/ 27.5 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Instantaneous; high blocking voltage | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3365-3BA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 65 A \/ 27.5 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Instantaneous; high blocking voltage | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3BA06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A \/ 27.5 A | Op voltage: 48-600 V AC | Control supply: 24 V DC | Switching: Instantaneous; high blocking voltage | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RF3380-3BA26\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-1 (400 V) \/ AC-15: 80 A \/ 27.5 A | Op voltage: 48-600 V AC | Control supply: 110-230 V AC | Switching: Instantaneous; high blocking voltage | Connection: Ring cable lug | Grounding: Heat sink screw terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67535293382946,"sku":"3RF3310-1AA02","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/siemens-sirius-3rf33-solid-state-contactors.jpg?v=1792150147","url":"https:\/\/prosourcemro.com\/products\/siemens-sirius-3rf33-solid-state-contactors","provider":"ProSource MRO","version":"1.0","type":"link"}