{"product_id":"siemens-sirius-3rm1-motor-starters","title":"Siemens SIRIUS 3RM1 Motor Starters (22.5 mm, 0.1-7 A)","description":"\u003cp class=\"ps-intro\"\u003eCompact 22.5 mm SIRIUS 3RM1 hybrid motor starters combining direct-on-line or reversing function with electronic overload protection, also as fail-safe versions.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eWidth only 22.5 mm, hybrid switching technology\u003c\/li\u003e\n\u003cli\u003eDirect-on-line, reversing and fail-safe versions\u003c\/li\u003e\n\u003cli\u003eOverload setting 0.1-0.5 A, 0.4-2 A or 1.6-7 A (up to 3 kW at 400 V)\u003c\/li\u003e\n\u003cli\u003eControl supply 24 V DC or 110 V DC \/ 110-230 V AC\u003c\/li\u003e\n\u003cli\u003eScrew, push-in or mixed terminal versions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct line\u003c\/th\u003e\n\u003ctd\u003eSIRIUS 3RM1 motor starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor readiness\u003c\/th\u003e\n\u003ctd\u003eIE3\/IE4 ready\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog chapter\u003c\/th\u003e\n\u003ctd\u003eIC 10 ch. 8: load feeders, motor starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003ctd\u003eMotor Starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog IC 10 · 2026, p. 842-843\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1001-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 24 V DC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1002-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 24 V DC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1007-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 24 V DC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1001-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1002-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1007-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1001-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 24 V DC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1002-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 24 V DC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1007-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 24 V DC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1001-2AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1002-2AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1007-2AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1001-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 24 V DC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1002-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 24 V DC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1007-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 24 V DC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1001-3AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1002-3AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1007-3AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Direct-on-line | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1201-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 24 V DC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1202-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 24 V DC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1207-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 24 V DC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1201-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1202-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1207-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1201-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 24 V DC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1202-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 24 V DC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1207-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 24 V DC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1201-2AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1202-2AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1207-2AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1201-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 24 V DC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1202-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 24 V DC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1207-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 24 V DC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1201-3AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1202-3AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1207-3AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Reversing | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1101-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 24 V DC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1102-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 24 V DC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1107-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 24 V DC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1101-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1102-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1107-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1101-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 24 V DC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1102-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 24 V DC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1107-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 24 V DC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1101-2AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1102-2AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1107-2AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1101-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 24 V DC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1102-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 24 V DC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1107-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 24 V DC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1101-3AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1102-3AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1107-3AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe direct-on-line | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1301-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 24 V DC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1302-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 24 V DC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1307-1AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 24 V DC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1301-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1302-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1307-1AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1301-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 24 V DC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1302-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 24 V DC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1307-2AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 24 V DC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1301-2AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1302-2AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1307-2AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Spring-loaded (push-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1301-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 24 V DC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1302-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 24 V DC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1307-3AA04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 24 V DC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1301-3AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0-0.12 kW | Overload setting: 0.1-0.5 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1302-3AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0.09-0.75 kW | Overload setting: 0.4-2 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RM1307-3AA14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Fail-safe reversing | Motor 400 V: 0.55-3 kW | Overload setting: 1.6-7 A | Control voltage: 110 V DC \/ 110-230 V AC | Terminals: Screw main \/ push-in control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67535294464290,"sku":"3RM1001-1AA04","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/siemens-sirius-3rm1-motor-starters.jpg?v=1792150147","url":"https:\/\/prosourcemro.com\/products\/siemens-sirius-3rm1-motor-starters","provider":"ProSource MRO","version":"1.0","type":"link"}