{"product_id":"siemens-sirius-3rv1011-motor-starter-protectors","title":"Siemens SIRIUS 3RV1011 Motor Starter Protectors (S00, up to 12 A)","description":"\u003cp class=\"ps-intro\"\u003eSIRIUS 3RV1011 motor starter protectors in size S00 provide class 10 overload and short-circuit protection for motors up to 12 A.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eClass 10 adjustable thermal overload release, 0.11 A to 12 A\u003c\/li\u003e\n\u003cli\u003eInstantaneous electronic short-circuit release, Icu 50-100 kA at 400 V AC\u003c\/li\u003e\n\u003cli\u003eVersions without auxiliary switch or with integrated transverse auxiliary switch 1 NO + 1 NC\u003c\/li\u003e\n\u003cli\u003eSize S00, screw terminals\u003c\/li\u003e\n\u003cli\u003eFurther 3RV2 accessories usable with exceptions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct line\u003c\/th\u003e\n\u003ctd\u003eSIRIUS 3RV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003ctd\u003eS00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClass\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003ctd\u003eScrew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog section\u003c\/th\u003e\n\u003ctd\u003eIC 10 ch. 7 Protection equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003ctd\u003eMotor Starter Protectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eDIN rail or screw fixing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSiemens Catalog IC 10 · 2026, p. 7\/75-7\/75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0AA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0BA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0CA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0DA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0EA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0FA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0GA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0HA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0JA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0KA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1AA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1BA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1CA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1DA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1EA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1FA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1GA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1HA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 50 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1JA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 50 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1KA10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 9–12 A | Motor rating: 5.5 kW | Icu 400 V: 50 kA | Aux. switch: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0AA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.11–0.16 A | Motor rating: 0.04 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0BA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.14–0.2 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0CA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.18–0.25 A | Motor rating: 0.06 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0DA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.22–0.32 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0EA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.28–0.4 A | Motor rating: 0.09 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0FA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.35–0.5 A | Motor rating: 0.12 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0GA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.45–0.63 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0HA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.55–0.8 A | Motor rating: 0.18 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0JA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.7–1 A | Motor rating: 0.25 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-0KA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 0.9–1.25 A | Motor rating: 0.37 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1AA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 1.1–1.6 A | Motor rating: 0.55 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1BA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 1.4–2 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1CA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 1.8–2.5 A | Motor rating: 0.75 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1DA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 2.2–3.2 A | Motor rating: 1.1 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1EA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 2.8–4 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1FA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 3.5–5 A | Motor rating: 1.5 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1GA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 4.5–6.3 A | Motor rating: 2.2 kW | Icu 400 V: 100 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1HA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 5.5–8 A | Motor rating: 3 kW | Icu 400 V: 50 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1JA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 7–10 A | Motor rating: 4 kW | Icu 400 V: 50 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3RV1011-1KA15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSetting range: 9–12 A | Motor rating: 5.5 kW | Icu 400 V: 50 kA | Aux. switch: Transverse 1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67534399963426,"sku":"3RV1011-0AA10","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/siemens-sirius-3rv1011-motor-starter-protectors.jpg?v=1792131833","url":"https:\/\/prosourcemro.com\/products\/siemens-sirius-3rv1011-motor-starter-protectors","provider":"ProSource MRO","version":"1.0","type":"link"}