{"product_id":"smc-amp-clean-room-exhaust-cleaner","title":"SMC AMP Exhaust Cleaner for Clean Room (Rc1\/4 to Rc3\/4)","description":"\u003cp class=\"ps-intro\"\u003eSMC AMP series exhaust cleaner that lets pneumatic equipment exhaust directly into a clean room without exhaust ducting.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eExhaust air cleanliness equivalent to ISO Class 5 (Fed.Std.209D class 100), 3.5 particles\/L or less of 0.3 µm\u003c\/li\u003e\n\u003cli\u003eTwo-stage element: the 2nd element catches oil passing after the 1st element saturates\u003c\/li\u003e\n\u003cli\u003eThree sizes AMP220\/320\/420 for 200, 500 and 1,000 L\/min (ANR)\u003c\/li\u003e\n\u003cli\u003eOptions: R (flow direction right to down) and T (clog checker; replace element when red spots appear)\u003c\/li\u003e\n\u003cli\u003eElement replacement at 0.1 MPa pressure drop or after one year, whichever comes first\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eCompressed air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInlet pressure\u003c\/th\u003e\n\u003ctd\u003e0.1 MPa or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient and fluid temperature\u003c\/th\u003e\n\u003ctd\u003e5 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFiltration\u003c\/th\u003e\n\u003ctd\u003e0.01 µm (95% capture efficiency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutlet cleanliness\u003c\/th\u003e\n\u003ctd\u003e100 particles\/ft³ or less (0.3 µm and larger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElement\u003c\/th\u003e\n\u003ctd\u003e2-stage element (AMP-EL220\/320\/420)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise reduction\u003c\/th\u003e\n\u003ctd\u003e40 dB(A) or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBracket\u003c\/th\u003e\n\u003ctd\u003eBM67 \/ BM66 \/ BM68, suffix B (shipped unassembled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog AMP Series (SMCKR_AMP_CLEAN.pdf), p. 1210-1214 (PDF p. 1-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP220-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP220 | Port size: Rc1\/4 | Max. flow [L\/min (ANR)]: 200 | Option: Standard | Mass: 0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP220-02-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP220 | Port size: Rc1\/4 | Max. flow [L\/min (ANR)]: 200 | Option: Flow right to down | Mass: 0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP220-02-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP220 | Port size: Rc1\/4 | Max. flow [L\/min (ANR)]: 200 | Option: With clog checker | Mass: 0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP220-02-RT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP220 | Port size: Rc1\/4 | Max. flow [L\/min (ANR)]: 200 | Option: Flow right to down + clog checker | Mass: 0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP220-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP220 | Port size: Rc3\/8 | Max. flow [L\/min (ANR)]: 200 | Option: Standard | Mass: 0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP220-03-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP220 | Port size: Rc3\/8 | Max. flow [L\/min (ANR)]: 200 | Option: Flow right to down | Mass: 0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP220-03-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP220 | Port size: Rc3\/8 | Max. flow [L\/min (ANR)]: 200 | Option: With clog checker | Mass: 0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP220-03-RT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP220 | Port size: Rc3\/8 | Max. flow [L\/min (ANR)]: 200 | Option: Flow right to down + clog checker | Mass: 0.43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP320-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP320 | Port size: Rc3\/8 | Max. flow [L\/min (ANR)]: 500 | Option: Standard | Mass: 0.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP320-03-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP320 | Port size: Rc3\/8 | Max. flow [L\/min (ANR)]: 500 | Option: Flow right to down | Mass: 0.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP320-03-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP320 | Port size: Rc3\/8 | Max. flow [L\/min (ANR)]: 500 | Option: With clog checker | Mass: 0.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP320-03-RT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP320 | Port size: Rc3\/8 | Max. flow [L\/min (ANR)]: 500 | Option: Flow right to down + clog checker | Mass: 0.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP320-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP320 | Port size: Rc1\/2 | Max. flow [L\/min (ANR)]: 500 | Option: Standard | Mass: 0.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP320-04-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP320 | Port size: Rc1\/2 | Max. flow [L\/min (ANR)]: 500 | Option: Flow right to down | Mass: 0.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP320-04-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP320 | Port size: Rc1\/2 | Max. flow [L\/min (ANR)]: 500 | Option: With clog checker | Mass: 0.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP320-04-RT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP320 | Port size: Rc1\/2 | Max. flow [L\/min (ANR)]: 500 | Option: Flow right to down + clog checker | Mass: 0.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP420-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP420 | Port size: Rc1\/2 | Max. flow [L\/min (ANR)]: 1000 | Option: Standard | Mass: 1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP420-04-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP420 | Port size: Rc1\/2 | Max. flow [L\/min (ANR)]: 1000 | Option: Flow right to down | Mass: 1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP420-04-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP420 | Port size: Rc1\/2 | Max. flow [L\/min (ANR)]: 1000 | Option: With clog checker | Mass: 1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP420-04-RT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP420 | Port size: Rc1\/2 | Max. flow [L\/min (ANR)]: 1000 | Option: Flow right to down + clog checker | Mass: 1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP420-06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP420 | Port size: Rc3\/4 | Max. flow [L\/min (ANR)]: 1000 | Option: Standard | Mass: 1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP420-06-R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP420 | Port size: Rc3\/4 | Max. flow [L\/min (ANR)]: 1000 | Option: Flow right to down | Mass: 1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP420-06-T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP420 | Port size: Rc3\/4 | Max. flow [L\/min (ANR)]: 1000 | Option: With clog checker | Mass: 1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMP420-06-RT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: AMP420 | Port size: Rc3\/4 | Max. flow [L\/min (ANR)]: 1000 | Option: Flow right to down + clog checker | Mass: 1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521657340194,"sku":"AMP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-amp-clean-room-exhaust-cleaner.jpg?v=1791950295","url":"https:\/\/prosourcemro.com\/products\/smc-amp-clean-room-exhaust-cleaner","provider":"ProSource MRO","version":"1.0","type":"link"}