{"product_id":"smc-arp20-40-direct-operated-precision-regulator","title":"SMC ARP20 to ARP40 Direct Operated Precision Regulator (Modular)","description":"\u003cp class=\"ps-intro\"\u003eSMC ARP20\/30\/40 direct operated precision regulator in modular style, sensitivity within 0.2% F.S., with optional backflow function (ARP20K-40K), ports Rc1\/8 to Rc1\/2.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eSensitivity within 0.2% F.S., repeatability within ±1% F.S. (or ±3 kPa)\u003c\/li\u003e\n\u003cli\u003eAir consumption reduced by up to 80% versus ARP3000 (0.8 L\/min at P2 = 0.3 MPa)\u003c\/li\u003e\n\u003cli\u003eBackflow function (K) quickly exhausts outlet pressure when supply is released\u003c\/li\u003e\n\u003cli\u003eThree set pressure ranges: 0.005-0.4 MPa (standard), 0.005-0.2 MPa (-1), 0.008-0.6 MPa (-3)\u003c\/li\u003e\n\u003cli\u003eOptions: bracket (B), set nut (H), square embedded or round gauge (E, G), digital pressure switch (E1-E0); flow R-L (R), handle rear (Y); NPT\/G threads\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. operating pressure\u003c\/th\u003e\n\u003ctd\u003e0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003eWithin 0.2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003e±1% F.S. (or ±3 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGauge port\u003c\/th\u003e\n\u003ctd\u003eARP20\/30 1\/8, ARP40 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConstruction\u003c\/th\u003e\n\u003ctd\u003eBleed type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient and fluid temperature\u003c\/th\u003e\n\u003ctd\u003e-5 to 60°C (no freezing); with digital switch -5 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMass\u003c\/th\u003e\n\u003ctd\u003eARP20 0.2 kg, ARP30 0.3 kg, ARP40 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog ARP20-40 (SMCKR_ARP20_30_40.pdf), p. 1043-1046 (PDF p. 1-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP20-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP20 | Backflow function: No | Port: Rc1\/8 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP20-01-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP20 | Backflow function: No | Port: Rc1\/8 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP20-01-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP20 | Backflow function: No | Port: Rc1\/8 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP20-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP20 | Backflow function: No | Port: Rc1\/4 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP20-02-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP20 | Backflow function: No | Port: Rc1\/4 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP20-02-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP20 | Backflow function: No | Port: Rc1\/4 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP20K-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP20 | Backflow function: Yes | Port: Rc1\/8 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP20K-01-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP20 | Backflow function: Yes | Port: Rc1\/8 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP20K-01-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP20 | Backflow function: Yes | Port: Rc1\/8 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP20K-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP20 | Backflow function: Yes | Port: Rc1\/4 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP20K-02-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP20 | Backflow function: Yes | Port: Rc1\/4 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP20K-02-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP20 | Backflow function: Yes | Port: Rc1\/4 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP30-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP30 | Backflow function: No | Port: Rc1\/4 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP30-02-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP30 | Backflow function: No | Port: Rc1\/4 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP30-02-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP30 | Backflow function: No | Port: Rc1\/4 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP30-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP30 | Backflow function: No | Port: Rc3\/8 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP30-03-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP30 | Backflow function: No | Port: Rc3\/8 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP30-03-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP30 | Backflow function: No | Port: Rc3\/8 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP30K-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP30 | Backflow function: Yes | Port: Rc1\/4 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP30K-02-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP30 | Backflow function: Yes | Port: Rc1\/4 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP30K-02-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP30 | Backflow function: Yes | Port: Rc1\/4 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP30K-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP30 | Backflow function: Yes | Port: Rc3\/8 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP30K-03-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP30 | Backflow function: Yes | Port: Rc3\/8 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP30K-03-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP30 | Backflow function: Yes | Port: Rc3\/8 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: No | Port: Rc1\/4 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40-02-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: No | Port: Rc1\/4 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40-02-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: No | Port: Rc1\/4 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: No | Port: Rc3\/8 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40-03-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: No | Port: Rc3\/8 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40-03-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: No | Port: Rc3\/8 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: No | Port: Rc1\/2 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40-04-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: No | Port: Rc1\/2 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40-04-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: No | Port: Rc1\/2 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40K-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: Yes | Port: Rc1\/4 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40K-02-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: Yes | Port: Rc1\/4 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40K-02-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: Yes | Port: Rc1\/4 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40K-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: Yes | Port: Rc3\/8 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40K-03-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: Yes | Port: Rc3\/8 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40K-03-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: Yes | Port: Rc3\/8 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40K-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: Yes | Port: Rc1\/2 | Set pressure range: 0.005-0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40K-04-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: Yes | Port: Rc1\/2 | Set pressure range: 0.005-0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP40K-04-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody size: ARP40 | Backflow function: Yes | Port: Rc1\/2 | Set pressure range: 0.008-0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521640694050,"sku":"ARP20","price":0.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/prosourcemro.com\/products\/smc-arp20-40-direct-operated-precision-regulator","provider":"ProSource MRO","version":"1.0","type":"link"}