{"product_id":"smc-c96-iso-cylinder-double-rod","title":"SMC C96 ISO 15552 Tie-rod Air Cylinder (Double Rod, ø32 to ø100)","description":"\u003cp class=\"ps-intro\"\u003eSMC C96 series ISO 15552 tie-rod air cylinder, double acting, double rod, ø32 to ø100 mm bore, with air cushion plus damper cushion and optional built-in magnet (C96SD).\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eISO 15552 compliant; lighter body than the previous C96 (up to 17% weight reduction)\u003c\/li\u003e\n\u003cli\u003eTwo-stage cushioning (air cushion + damper) shortens cycle time and reduces impact noise\u003c\/li\u003e\n\u003cli\u003eMounting styles: basic (B), axial foot (L), rod\/head flange (F\/G), single\/double clevis (C\/D), center trunnion (T), adjustable trunnion (V)\u003c\/li\u003e\n\u003cli\u003eCompact D-M9 \/ D-A9 auto switches mount directly on the tie rod and adjust from one direction; tie-rod and band mount switches also available\u003c\/li\u003e\n\u003cli\u003eBellows (J, JJ, K, KK), auto switches and made-to-order specs (-XA, -XB6, -XB7, -XC14, -XC35 etc.) ordered as suffixes\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003eISO 15552\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAction\u003c\/th\u003e\n\u003ctd\u003eDouble acting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. operating pressure\u003c\/th\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMin. operating pressure\u003c\/th\u003e\n\u003ctd\u003e0.05 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient and fluid temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to 70°C without switch, -10 to 60°C with switch (no freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePiston speed\u003c\/th\u003e\n\u003ctd\u003e50 to 1000 mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eNot required (non-lube)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCushion\u003c\/th\u003e\n\u003ctd\u003eAir cushion + damper cushion on both ends (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRod\u003c\/th\u003e\n\u003ctd\u003eDouble Rod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. stroke\u003c\/th\u003e\n\u003ctd\u003eø32 1000 mm, ø40 to ø100 1900 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog C96 (SMCKR_C96.pdf), p. 161-162 (PDF p. 4-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SB100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDB100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Basic | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SL100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDL100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Axial foot | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SF100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDF100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Rod flange | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SG100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDG100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Head flange | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SC100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDC100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Single clevis | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SD100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDD100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Double clevis | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96ST100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDT100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Center trunnion | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV32-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV32-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV32-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV32-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV32-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV32-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV32-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV32-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV32-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV32-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV32-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø32 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV40-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV40-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV40-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV40-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV40-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV40-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV40-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV40-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV40-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV40-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV40-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø40 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV50-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV50-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV50-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV50-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV50-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV50-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV50-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV50-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV50-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV50-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV50-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV50-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø50 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV63-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV63-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV63-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV63-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV63-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV63-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV63-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV63-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV63-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV63-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV63-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV63-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø63 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV80-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø80 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-25CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 25 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-50CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 50 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-80CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 80 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-100CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 100 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-125CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 125 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-160CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 160 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-200CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 200 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-250CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 250 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-320CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 320 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-400CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 400 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-500CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 500 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-600CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 600 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-700CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 700 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SV100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: No | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC96SDV100-800CW\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting: Adjustable trunnion | Bore: ø100 mm | Stroke: 800 mm | Auto switch magnet: Yes | Port: G1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521600651554,"sku":"C96","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-c96-iso-cylinder-double-rod.jpg?v=1791950298","url":"https:\/\/prosourcemro.com\/products\/smc-c96-iso-cylinder-double-rod","provider":"ProSource MRO","version":"1.0","type":"link"}