{"product_id":"smc-cc-air-hydro-unit","title":"SMC CC Air-Hydro Unit (Converter + Valve Unit, ø63 to ø160)","description":"\u003cp class=\"ps-intro\"\u003eSMC CC series air-hydro unit combining an air-hydro converter and valve unit in one body, converting air pressure into equal hydraulic pressure for smooth, constant-speed actuator drive.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eConstant-speed drive at start and under load fluctuation; eliminates stick-slip at low speed\u003c\/li\u003e\n\u003cli\u003eFor precise constant feed, intermediate stop, skip feed and cushioned drive of rotary actuators\u003c\/li\u003e\n\u003cli\u003eConverter ø63, ø100, ø160; small-flow (S) or large-flow (L) valve unit\u003c\/li\u003e\n\u003cli\u003eControl valve: flow control with pressure compensation, orifice, or micro flow control (S only)\u003c\/li\u003e\n\u003cli\u003eCompound valve: stop + skip, stop only or skip only; solenoid AC100V, AC200V, DC24V (grommet or DIN) or air operated\u003c\/li\u003e\n\u003cli\u003eSemi-standard voltages AC110V, AC220V, DC12V, AC240V (symbols 3, 4, 6, 7) on order\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 to 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.05 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient and fluid temperature\u003c\/th\u003e\n\u003ctd\u003e5 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eTurbine oil (40 to 100 mm²\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConverter float and baffles\u003c\/th\u003e\n\u003ctd\u003ePrevent air dissolving in oil and bubble formation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompound valve solenoid\u003c\/th\u003e\n\u003ctd\u003eVO307 type, external pilot 0.3 to 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog CC series (SMCKR_CC_CCT_CCV.pdf), p. 1260-1262 (PDF p. 6-8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S02-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S02-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S02-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S02-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S02-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S02-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S02-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S11-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S11-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S11-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S11-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S11-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S11-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S11-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S12-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S12-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S12-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S12-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S12-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S12-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S12-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S13-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S13-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S13-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S13-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S13-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S13-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S13-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S21-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S21-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S21-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S21-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S21-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S21-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S21-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S22-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S22-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S22-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S22-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S22-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S22-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S22-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S23-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S23-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S23-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S23-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S23-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S23-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S23-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S31-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S31-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S31-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S31-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S31-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S31-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S31-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S32-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S32-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S32-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S32-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S32-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S32-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S32-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S33-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S33-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S33-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S33-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S33-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S33-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-50S33-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 50 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S02-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S02-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S02-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S02-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S02-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S02-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S02-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S11-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S11-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S11-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S11-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S11-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S11-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S11-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S12-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S12-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S12-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S12-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S12-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S12-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S12-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S13-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S13-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S13-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S13-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S13-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S13-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S13-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S21-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S21-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S21-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S21-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S21-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S21-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S21-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S22-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S22-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S22-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S22-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S22-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S22-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S22-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S23-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S23-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S23-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S23-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S23-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S23-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S23-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S31-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S31-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S31-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S31-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S31-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S31-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S31-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S32-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S32-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S32-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S32-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S32-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S32-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S32-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S33-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S33-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S33-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S33-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S33-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S33-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-100S33-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S02-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S02-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S02-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S02-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S02-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S02-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S02-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S11-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S11-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S11-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S11-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S11-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S11-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S11-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S12-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S12-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S12-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S12-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S12-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S12-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S12-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S13-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S13-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S13-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S13-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S13-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S13-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S13-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S21-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S21-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S21-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S21-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S21-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S21-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S21-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S22-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S22-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S22-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S22-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S22-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S22-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S22-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S23-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S23-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S23-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S23-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S23-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S23-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S23-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S31-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S31-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S31-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S31-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S31-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S31-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S31-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S32-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S32-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S32-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S32-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S32-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S32-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S32-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S33-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S33-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S33-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S33-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S33-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S33-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-200S33-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S02-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S02-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S02-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S02-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S02-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S02-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S02-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S11-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S11-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S11-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S11-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S11-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S11-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S11-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S12-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S12-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S12-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S12-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S12-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S12-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S12-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S13-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S13-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S13-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S13-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S13-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S13-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S13-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S21-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S21-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S21-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S21-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S21-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S21-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S21-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S22-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S22-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S22-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S22-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S22-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S22-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S22-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S23-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S23-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S23-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S23-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S23-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S23-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S23-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S31-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S31-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S31-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S31-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S31-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S31-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S31-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S32-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S32-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S32-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S32-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S32-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S32-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S32-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S33-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S33-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S33-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S33-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S33-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S33-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-300S33-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S02-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S02-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S02-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S02-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S02-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S02-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S02-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S11-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S11-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S11-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S11-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S11-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S11-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S11-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S12-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S12-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S12-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S12-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S12-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S12-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S12-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S13-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S13-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S13-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S13-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S13-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S13-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S13-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S21-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S21-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S21-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S21-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S21-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S21-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S21-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S22-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S22-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S22-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S22-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S22-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S22-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S22-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S23-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S23-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S23-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S23-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S23-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S23-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S23-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S31-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S31-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S31-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S31-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S31-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S31-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S31-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S32-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S32-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S32-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S32-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S32-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S32-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S32-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S33-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S33-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S33-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S33-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S33-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S33-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-400S33-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 400 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S02-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S02-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S02-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S02-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S02-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S02-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S02-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S11-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S11-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S11-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S11-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S11-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S11-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S11-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S12-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S12-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S12-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S12-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S12-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S12-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S12-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S13-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S13-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S13-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S13-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S13-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S13-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S13-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S21-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S21-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S21-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S21-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S21-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S21-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S21-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S22-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S22-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S22-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S22-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S22-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S22-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S22-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S23-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S23-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S23-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S23-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S23-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S23-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S23-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S31-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S31-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S31-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S31-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S31-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S31-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S31-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S32-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S32-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S32-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S32-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S32-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S32-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S32-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S33-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S33-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S33-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S33-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S33-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S33-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC63-500S33-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø63 mm | Stroke: 500 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S02-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S02-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S02-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S02-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S02-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S02-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S02-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S11-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S11-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S11-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S11-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S11-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S11-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S11-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S12-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S12-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S12-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S12-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S12-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S12-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S12-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S13-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S13-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S13-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S13-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S13-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S13-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S13-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S21-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S21-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S21-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S21-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S21-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S21-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S21-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S22-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S22-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S22-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S22-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S22-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S22-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S22-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S23-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S23-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S23-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S23-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S23-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S23-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S23-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S31-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S31-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S31-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S31-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S31-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S31-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S31-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S32-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S32-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S32-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S32-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S32-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S32-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S32-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S33-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S33-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S33-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S33-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S33-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S33-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100S33-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L02-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L02-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L02-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L02-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L02-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L02-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L02-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L11-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L11-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L11-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L11-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L11-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L11-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L11-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L12-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L12-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L12-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L12-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L12-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L12-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L12-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L13-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L13-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L13-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L13-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L13-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L13-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L13-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L21-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L21-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L21-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L21-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L21-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L21-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L21-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L22-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L22-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L22-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L22-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L22-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L22-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L22-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L23-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L23-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L23-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L23-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L23-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L23-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-100L23-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 100 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S02-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S02-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S02-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S02-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S02-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S02-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S02-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S11-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S11-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S11-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S11-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S11-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S11-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S11-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S12-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S12-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S12-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S12-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S12-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S12-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S12-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S13-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S13-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S13-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S13-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S13-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S13-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S13-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S21-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S21-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S21-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S21-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S21-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S21-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S21-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S22-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S22-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S22-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S22-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S22-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S22-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S22-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S23-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S23-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S23-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S23-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S23-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S23-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S23-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S31-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S31-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S31-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S31-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S31-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S31-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S31-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S32-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S32-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S32-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S32-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S32-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S32-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S32-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S33-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S33-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S33-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S33-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S33-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S33-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200S33-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L02-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L02-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L02-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L02-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L02-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L02-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L02-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L11-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L11-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L11-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L11-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L11-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L11-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L11-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L12-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L12-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L12-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L12-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L12-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L12-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L12-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L13-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L13-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L13-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L13-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L13-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L13-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L13-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L21-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L21-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L21-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L21-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L21-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L21-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L21-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L22-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L22-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L22-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L22-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L22-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L22-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L22-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L23-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L23-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L23-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L23-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L23-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L23-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-200L23-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 200 mm | Valve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S02-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S02-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S02-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S02-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S02-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S02-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S02-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S11-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S11-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S11-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S11-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S11-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S11-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S11-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S12-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S12-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S12-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S12-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S12-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S12-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S12-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S13-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S13-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S13-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S13-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S13-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S13-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S13-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S21-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S21-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S21-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S21-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S21-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S21-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S21-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S22-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S22-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S22-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S22-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S22-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S22-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S22-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S23-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S23-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S23-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S23-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S23-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S23-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S23-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S31-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S31-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S31-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S31-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S31-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S31-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S31-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S32-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S32-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S32-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S32-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S32-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S32-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S32-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S33-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S33-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S33-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S33-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S33-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S33-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300S33-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300L02-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300L02-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300L02-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300L02-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300L02-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300L02-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300L02-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300L10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300L11-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300L11-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC100-300L11-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter: ø100 mm | Stroke: 300 mm | Valve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521576304930,"sku":"CC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-cc-air-hydro-unit.jpg?v=1791950317","url":"https:\/\/prosourcemro.com\/products\/smc-cc-air-hydro-unit","provider":"ProSource MRO","version":"1.0","type":"link"}