{"product_id":"smc-ccv-air-hydro-valve-unit","title":"SMC CCVS\/CCVL Valve Unit for Air-Hydro Systems","description":"\u003cp class=\"ps-intro\"\u003eSMC CCVS (small flow) and CCVL (large flow) valve unit for air-hydro circuits, combining a control valve and a stop\/skip compound valve, as an individual valve or for mounting on CCT converters.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eControl valve: flow control with pressure compensation (±10%), orifice valve, or micro flow control (CCVS only)\u003c\/li\u003e\n\u003cli\u003eCompound valve: stop + skip valve, stop only or skip only (N.C.), solenoid or air operated\u003c\/li\u003e\n\u003cli\u003eIndividual valve (S) or unit type for CCT63 (U1) and CCT100\/160 (U2)\u003c\/li\u003e\n\u003cli\u003eSolenoid AC100V, AC200V, DC24V with grommet or DIN terminal; semi-standard voltages on order\u003c\/li\u003e\n\u003cli\u003eCE\/UKCA compliant version (suffix -Q) available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 to 0.7 MPa (flow control valve 0.3 to 0.7 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExternal pilot pressure\u003c\/th\u003e\n\u003ctd\u003e0.3 to 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.05 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient and fluid temperature\u003c\/th\u003e\n\u003ctd\u003e5 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eTurbine oil (40 to 100 mm²\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEffective area (stop\/skip valve)\u003c\/th\u003e\n\u003ctd\u003eSmall flow 40 mm², large flow 88 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOil connection\u003c\/th\u003e\n\u003ctd\u003eCCVS Rc1\/2, CCVL Rc3\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog CC series (SMCKR_CC_CCT_CCV.pdf), p. 1264-1265 (PDF p. 10-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS10-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS20-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS30-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: None | Solenoid: None | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-0-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-1G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-1D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-2G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-2D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-5G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-5D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS10-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-0-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-1G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-1D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-2G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-2D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-5G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-5D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-0-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-1G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-1D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-2G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-2D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-5G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-5D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-0-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-1G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-1D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-2G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-2D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-5G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-5D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS20-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-0-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-1G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-1D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-2G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-2D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-5G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-5D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-0-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-1G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-1D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-2G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-2D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-5G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-5D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-0-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-1G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-1D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-2G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-2D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-5G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-5D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS30-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: None | Solenoid: None | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-0-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-1G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-1D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-2G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-2D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-5G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-5D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-0-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-1G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-1D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-2G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-2D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-5G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-5D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-0-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-1G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-1D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-2G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-2D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-5G-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-5D-U1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC63 (CCT63)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS02-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS10-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS11-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS12-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS13-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS20-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS21-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS22-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS23-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS30-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: None | Solenoid: None | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS31-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS32-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVS33-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Small flow | Control valve: Micro flow control | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL10-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL20-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-0-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-1G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-1D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-2G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-2D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-5G-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-5D-S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Individual valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL02-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: None | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL10-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: None | Solenoid: None | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL11-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL12-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL13-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Flow control (press. comp.) | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL20-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: None | Solenoid: None | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL21-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop + skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL22-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Stop valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-0-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: Air operated | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-1G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-1D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC100V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-2G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-2D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: AC200V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-5G-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V grommet | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCVL23-5D-U2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eValve unit: Large flow | Control valve: Orifice valve | Compound valve: Skip valve | Solenoid: DC24V DIN terminal | Mounting: Unit for CC100\/CC160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521576632610,"sku":"CCVS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-ccv-air-hydro-valve-unit.jpg?v=1791950317","url":"https:\/\/prosourcemro.com\/products\/smc-ccv-air-hydro-valve-unit","provider":"ProSource MRO","version":"1.0","type":"link"}