{"product_id":"smc-crp-compact-compressor","title":"SMC CRP Compact Compressor (Oil-Free, for Co-Robots and AGVs)","description":"\u003cp class=\"ps-intro\"\u003eSMC CRP10 oil-free compact compressor with separate DC24V controller that supplies compressed air or vacuum where no plant air is available, such as on collaborative robots and AGVs.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eOne unit works as a pressure source (max. 0.55 MPa) or vacuum pump (-70 kPa), reaching -70 kPa in about 0.2 s\u003c\/li\u003e\n\u003cli\u003eOil-free reciprocating compressor with brushless motor, discharge flow up to 10 L\/min (ANR)\u003c\/li\u003e\n\u003cli\u003eSmall and light: 154 x 134 x 100 mm, 3.5 kg (compressor 3.1 kg, controller 0.4 kg)\u003c\/li\u003e\n\u003cli\u003ePressure ON-OFF control with ISE20A digital pressure switch (M\/P), alarm LED on the controller\u003c\/li\u003e\n\u003cli\u003eOptional intake silencer (A\/B), one-touch check valve AKH06-00 (K) and 3-port valve V124 (V) for residual exhaust\u003c\/li\u003e\n\u003cli\u003eHorizontal or vertical installation; motor and sensor cables 1 m included\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompression method\u003c\/th\u003e\n\u003ctd\u003eReciprocating, oil-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. discharge pressure \/ vacuum\u003c\/th\u003e\n\u003ctd\u003e0.55 MPa \/ -70 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. discharge \/ suction flow\u003c\/th\u003e\n\u003ctd\u003e10 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated time\u003c\/th\u003e\n\u003ctd\u003eContinuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise\u003c\/th\u003e\n\u003ctd\u003e62 dB (AN10-01), 55 dB (ANB1-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController power supply\u003c\/th\u003e\n\u003ctd\u003eDC24V ±10%, rated 4.5 A (110 W), peak 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature \/ humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 40°C, 80% RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeal material\u003c\/th\u003e\n\u003ctd\u003ePTFE (sliding), HNBR (O-ring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog CAT.KS30-24B (SMCKR_CRP.pdf), p. 4-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-AM-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-AM-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-AM-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-AM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-AP-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-AP-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-AP-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-AP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-A-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: None | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-A-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: None | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-A-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: None | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: None | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-BM-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-BM-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-BM-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-BM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-BP-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-BP-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-BP-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-BP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-B-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: None | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-B-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: None | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-B-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: None | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: None | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-M-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-M-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-M-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-P-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-P-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-P-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-S1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: Screw mounting | Intake silencer: None (75 dB) | Pressure switch: None | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-AM-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-AM-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-AM-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-AM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-AP-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-AP-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-AP-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-AP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-A-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: None | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-A-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: None | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-A-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: None | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: AN10-01 (62 dB) | Pressure switch: None | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-BM-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-BM-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-BM-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-BM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-BP-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-BP-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-BP-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-BP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-B-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: None | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-B-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: None | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-B-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: None | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: ANB1-01 (55 dB) | Pressure switch: None | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-M-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-M-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-M-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-M-01-J-X603 (SI fixed) | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-P-KV\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-P-K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: AKH06-00 (ø6) | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-P-V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: None | Residual exhaust valve: V124-5LU-M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: None (75 dB) | Pressure switch: ISE20A-Y-01-J-X603 | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRP10-D1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eController mounting: DIN rail mounting | Intake silencer: None (75 dB) | Pressure switch: None | Residual exhaust check valve: None | Residual exhaust valve: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521633026338,"sku":"CRP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-crp-compact-compressor.jpg?v=1791950319","url":"https:\/\/prosourcemro.com\/products\/smc-crp-compact-compressor","provider":"ProSource MRO","version":"1.0","type":"link"}