{"product_id":"smc-d-reed-auto-switch","title":"SMC D Series Reed Auto Switches (D-A9, D-C7, D-A7, D-A5 ...)","description":"\u003cp class=\"ps-intro\"\u003eSMC D series reed (contact type) auto switches for SMC actuators, in direct, band, rail and tie-rod mounting with grommet, connector, terminal conduit or DIN terminal entry.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eGeneral-purpose reed switches for relay\/PLC (DC24V, AC100V, AC200V) or IC circuits (DC4 to 8V)\u003c\/li\u003e\n\u003cli\u003eVersions with indicator LED or without indicator (D-A90, D-C80, D-A80 etc.) for wider load voltage\u003c\/li\u003e\n\u003cli\u003e2-color indication types D-B59W, D-A79W, D-A59W show the optimum operating range\u003c\/li\u003e\n\u003cli\u003eMagnetic field resistant (D-P79WSE, D-P74) and heat resistant up to 120°C (D-B30\/B31\/B35) versions\u003c\/li\u003e\n\u003cli\u003eLead wire length is a suffix: none = 0.5 m, M = 1 m, L = 3 m, Z = 5 m (availability by model)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch type\u003c\/th\u003e\n\u003ctd\u003eReed (contact type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWiring\u003c\/th\u003e\n\u003ctd\u003e2-wire (D-C76\/A76H\/A56 type 3-wire for IC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad current\u003c\/th\u003e\n\u003ctd\u003eApprox. 5 to 50 mA depending on model and voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact protection\u003c\/th\u003e\n\u003ctd\u003eBuilt-in on AC types (q circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLead wire length\u003c\/th\u003e\n\u003ctd\u003e0.5 m standard; M 1 m, L 3 m, Z 5 m suffix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector cable (C types)\u003c\/th\u003e\n\u003ctd\u003eD-LC05 \/ D-LC30 \/ D-LC50 ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eCE marking (by model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog Auto Switches (SMCKR_D.pdf), p. 1651-1673 (PDF p. 71-93)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A90\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Direct | Electrical entry: Grommet, in-line | Load: IC\/relay\/PLC, AC\/DC 24V or less | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A93\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Direct | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V\/AC100V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A96\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Direct | Electrical entry: Grommet, in-line | Load: IC circuit, DC4-8V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A90V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Direct | Electrical entry: Grommet, perpendicular | Load: IC\/relay\/PLC, AC\/DC 24V or less | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A93V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Direct | Electrical entry: Grommet, perpendicular | Load: Relay\/PLC, DC24V\/AC100V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A96V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Direct | Electrical entry: Grommet, perpendicular | Load: IC circuit, DC4-8V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-Z73\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Direct | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V\/AC100V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-Z76\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Direct | Electrical entry: Grommet, in-line | Load: IC circuit, DC4-8V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-Z80\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Direct | Electrical entry: Grommet, in-line | Load: Relay\/PLC\/IC, AC\/DC up to 100V | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-E73A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Direct | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V\/AC100V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-E76A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Direct | Electrical entry: Grommet, in-line | Load: IC circuit, DC4-8V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-E80A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Direct | Electrical entry: Grommet, in-line | Load: Relay\/PLC\/IC, AC\/DC up to 100V | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-C73\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V\/AC100V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-C76\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: Grommet, in-line | Load: IC circuit, DC4-8V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-C80\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: Grommet, in-line | Load: Relay\/PLC\/IC, AC\/DC up to 100V | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-B53\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: Grommet, in-line | Load: PLC, DC24V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-B54\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-B64\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-C73C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: Connector | Load: Relay\/PLC, DC24V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-C80C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: Connector | Load: Relay\/PLC, AC\/DC 24V or less | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: Terminal conduit | Load: PLC, DC24V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A34\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: Terminal conduit | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A33A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: Terminal conduit | Load: PLC, DC24V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A34A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: Terminal conduit | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A44\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: DIN terminal | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A44A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Band | Electrical entry: DIN terminal | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A72\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Rail | Electrical entry: Grommet, in-line | Load: Relay\/PLC, AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A73\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Rail | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V\/AC100V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A80\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Rail | Electrical entry: Grommet, in-line | Load: Relay\/PLC\/IC, AC\/DC up to 100V | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A72H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Rail | Electrical entry: Grommet, in-line | Load: Relay\/PLC, AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A73H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Rail | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V\/AC100V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A76H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Rail | Electrical entry: Grommet, in-line | Load: IC circuit, DC4-8V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A80H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Rail | Electrical entry: Grommet, in-line | Load: Relay\/PLC\/IC, AC\/DC up to 100V | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A73C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Rail | Electrical entry: Connector | Load: Relay\/PLC, DC24V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A80C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Rail | Electrical entry: Connector | Load: Relay\/PLC\/IC, AC\/DC 24V or less | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A53\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod | Electrical entry: Grommet, in-line | Load: PLC, DC24V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A54\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A56\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod | Electrical entry: Grommet, in-line | Load: IC circuit, DC4-8V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A64\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A67\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod | Electrical entry: Grommet, in-line | Load: PLC\/IC, max. DC24V | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A33C-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 40 mm) | Electrical entry: Terminal conduit | Load: PLC, DC24V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A34C-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 40 mm) | Electrical entry: Terminal conduit | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A44C-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 40 mm) | Electrical entry: DIN terminal | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A33C-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 50 mm) | Electrical entry: Terminal conduit | Load: PLC, DC24V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A34C-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 50 mm) | Electrical entry: Terminal conduit | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A44C-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 50 mm) | Electrical entry: DIN terminal | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A33C-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 60 mm) | Electrical entry: Terminal conduit | Load: PLC, DC24V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A34C-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 60 mm) | Electrical entry: Terminal conduit | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A44C-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 60 mm) | Electrical entry: DIN terminal | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A33C-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 80 mm) | Electrical entry: Terminal conduit | Load: PLC, DC24V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A34C-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 80 mm) | Electrical entry: Terminal conduit | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A44C-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 80 mm) | Electrical entry: DIN terminal | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A33C-10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 100 mm) | Electrical entry: Terminal conduit | Load: PLC, DC24V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A34C-10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 100 mm) | Electrical entry: Terminal conduit | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A44C-10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: General purpose | Mounting: Tie-rod (bore 100 mm) | Electrical entry: DIN terminal | Load: Relay\/PLC, DC24V\/AC100V\/AC200V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-B59W\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: 2-color indication | Mounting: Band | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V | Indicator: LED red\/green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A79W\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: 2-color indication | Mounting: Rail | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V | Indicator: LED red\/green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-A59W\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: 2-color indication | Mounting: Tie-rod | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V | Indicator: LED red\/green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-P79WSE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: 2-color, magnetic field resistant | Mounting: Rod | Electrical entry: Pre-wired M12 connector | Load: PLC, DC24V | Indicator: LED red\/green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-P74\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Magnetic field resistant | Mounting: Rod | Electrical entry: Grommet, in-line | Load: Relay\/PLC, DC24V | Indicator: LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-B30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Heat resistant (-10 to 120°C) | Mounting: Band | Electrical entry: Terminal conduit | Load: PLC, DC24V\/AC100V | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-B30J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Heat resistant (-10 to 120°C) | Mounting: Band | Electrical entry: Grommet, in-line | Load: PLC, DC24V\/AC100V | Indicator: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-B31\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Heat resistant (-10 to 120°C) | Mounting: Band | Electrical entry: Terminal conduit | Load: PLC, AC100V | Indicator: Neon lamp (lit when OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-B31J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Heat resistant (-10 to 120°C) | Mounting: Band | Electrical entry: Grommet, in-line | Load: PLC, AC100V | Indicator: Neon lamp (lit when OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-B35\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Heat resistant (-10 to 120°C) | Mounting: Band | Electrical entry: Terminal conduit | Load: PLC, DC24V | Indicator: LED (lit when OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD-B35J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFunction: Heat resistant (-10 to 120°C) | Mounting: Band | Electrical entry: Grommet, in-line | Load: PLC, DC24V | Indicator: LED (lit when OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521602289954,"sku":"D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-d-reed-auto-switch.jpg?v=1791950320","url":"https:\/\/prosourcemro.com\/products\/smc-d-reed-auto-switch","provider":"ProSource MRO","version":"1.0","type":"link"}