{"product_id":"smc-in502-air-flow-controller","title":"SMC IN502-44\/45\/46 Air Flow Controller (50 to 2000 L\/min)","description":"\u003cp class=\"ps-intro\"\u003eSMC IN502-44\/45\/46 air flow controller that automatically adjusts dry air or N2 flow up to 2000 L\/min to follow an analog or IO-Link flow command.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eRated control flow 50-500, 100-1000 and 200-2000 L\/min; control accuracy ±5% F.S.\u003c\/li\u003e\n\u003cli\u003eSettling time 0.5 s or less (within ±5% F.S. of command)\u003c\/li\u003e\n\u003cli\u003eAnalog voltage or current I\/O with switch output, optionally IO-Link\u003c\/li\u003e\n\u003cli\u003eSelectable power-off behavior: flow zero or flow hold\u003c\/li\u003e\n\u003cli\u003e3-screen LCD; Rc1\/2 ports; M12 lead wires EX500-AP \/ EX9-AC and brackets ZS-56-A\/B ordered separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir, N2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply pressure\u003c\/th\u003e\n\u003ctd\u003e1.0 MPa or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad pressure\u003c\/th\u003e\n\u003ctd\u003e0.1 to 0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e24 VDC ±10%, 0.2 A or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePort size\u003c\/th\u003e\n\u003ctd\u003eRc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMass\u003c\/th\u003e\n\u003ctd\u003eApprox. 760 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eCE\/UKCA, UL\/CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog CAT.KS100-166A (SMCKR_IN502.pdf), PDF p. 6-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-1A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-2A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-3A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-3B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-4A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-7A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-7B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-8A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-8B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-9A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-9B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-10B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-11\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-11A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-11B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-12A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-12B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-13A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-13B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-14A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-14B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-15A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-15B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-16A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-44-16B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 50 to 500 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-1A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-2A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-3A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-3B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-4A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-7A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-7B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-8A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-8B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-9A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-9B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-10B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-11\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-11A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-11B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-12A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-12B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-13A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-13B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-14A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-14B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-15A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-15B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-16A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-45-16B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 100 to 1000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-1A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-1B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-2A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-2B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-3A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-3B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-4A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-6\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-7A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-7B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-8A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-8B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow zero | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-9A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-9B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + switch | Units: SI fixed | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-10B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + switch | Units: Unit selection | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-11\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-11A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-11B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + switch | Units: SI fixed | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-12A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-12B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + switch | Units: Unit selection | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-13\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-13A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-13B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-14\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-14A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-14B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog voltage + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-15A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-15B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: SI fixed | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: Low-dew-point grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-16A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: White vaseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIN502-46-16B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 200 to 2000 L\/min | I\/O: Analog current + IO-Link\/switch | Units: Unit selection | Power-off action: Flow hold | Grease: Food-grade grease\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521665990946,"sku":"IN502-44","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-in502-air-flow-controller.jpg?v=1791950339","url":"https:\/\/prosourcemro.com\/products\/smc-in502-air-flow-controller","provider":"ProSource MRO","version":"1.0","type":"link"}