{"product_id":"smc-lvm20-200-compact-chemical-solenoid-valve","title":"SMC LVM20\/200 Compact Direct Operated 2\/3-Port Chemical Valve","description":"\u003cp class=\"ps-intro\"\u003eSMC LVM20\/200 series direct operated rocker-type 2\/3-port solenoid valve for chemicals, 20 mm wide, direct piping (tube insertion) or base mounted with PVDF Rc1\/8 sub-plate.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eDirect operated rocker type with isolating diaphragm, N.C., N.O. and universal (3-port) valve types\u003c\/li\u003e\n\u003cli\u003e20 mm valve width, 21 mm manifold pitch\u003c\/li\u003e\n\u003cli\u003eOrifice 2 mm, Kv 0.055, internal valve volume 84 µL\u003c\/li\u003e\n\u003cli\u003eLow-power circuit version (Y): 4 W start, 0.6 W holding\u003c\/li\u003e\n\u003cli\u003eWetted parts PEEK with EPDM, FKM or Kalrez diaphragm; PVDF sub-plate Rc1\/8 (G1\/8, NPT1\/8 on order)\u003c\/li\u003e\n\u003cli\u003eLead wire entry\/length (grommet 150 to 1000 mm, plug connector K\/KO\/KZ\/KOZ), CE\/UKCA (Q) and DC12V coil are specified as suffixes; listed codes are DC24V with standard lead wire\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve construction\u003c\/th\u003e\n\u003ctd\u003eDirect operated rocker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e-75 kPa to 0.25 MPa (base 3-port 0.3 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse time\u003c\/th\u003e\n\u003ctd\u003e20 ms or less (air); low-power OFF 40 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir, water, deionized water, diluted chemicals, cleaning fluid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003eDC24V (DC12V also available, symbol 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAllowable voltage fluctuation\u003c\/th\u003e\n\u003ctd\u003e±10% of rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil insulation\u003c\/th\u003e\n\u003ctd\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP40 equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient and fluid temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 50°C (no freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLeakage\u003c\/th\u003e\n\u003ctd\u003e0 internal and external (with water)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog LVM Series (SMCKR_LVM.pdf), p. 359-365 (PDF p. 32-38)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R1-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 2-port N.C. | Circuit: Standard | Body diaphragm: PEEK \/ EPDM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R1-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 2-port N.C. | Circuit: Standard | Body diaphragm: PEEK \/ FKM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R1-5C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 2-port N.C. | Circuit: Standard | Body diaphragm: PEEK \/ Kalrez | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R1Y-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 2-port N.C. | Circuit: Low-power | Body diaphragm: PEEK \/ EPDM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R1Y-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 2-port N.C. | Circuit: Low-power | Body diaphragm: PEEK \/ FKM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R1Y-5C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 2-port N.C. | Circuit: Low-power | Body diaphragm: PEEK \/ Kalrez | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R2-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 2-port N.O. | Circuit: Standard | Body diaphragm: PEEK \/ EPDM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R2-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 2-port N.O. | Circuit: Standard | Body diaphragm: PEEK \/ FKM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R2-5C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 2-port N.O. | Circuit: Standard | Body diaphragm: PEEK \/ Kalrez | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R2Y-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 2-port N.O. | Circuit: Low-power | Body diaphragm: PEEK \/ EPDM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R2Y-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 2-port N.O. | Circuit: Low-power | Body diaphragm: PEEK \/ FKM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R2Y-5C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 2-port N.O. | Circuit: Low-power | Body diaphragm: PEEK \/ Kalrez | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM202R-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 3-port Universal | Circuit: Standard | Body diaphragm: PEEK \/ EPDM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM202R-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 3-port Universal | Circuit: Standard | Body diaphragm: PEEK \/ FKM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM202R-5C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 3-port Universal | Circuit: Standard | Body diaphragm: PEEK \/ Kalrez | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM202RY-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 3-port Universal | Circuit: Low-power | Body diaphragm: PEEK \/ EPDM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM202RY-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 3-port Universal | Circuit: Low-power | Body diaphragm: PEEK \/ FKM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM202RY-5C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Direct (tube insertion) | Valve: 3-port Universal | Circuit: Low-power | Body diaphragm: PEEK \/ Kalrez | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Standard | Body diaphragm: PEEK \/ EPDM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3-5AP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Standard | Body diaphragm: PEEK \/ EPDM | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3-5A1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Standard | Body diaphragm: PEEK \/ EPDM | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Standard | Body diaphragm: PEEK \/ FKM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3-5BP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Standard | Body diaphragm: PEEK \/ FKM | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3-5B1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Standard | Body diaphragm: PEEK \/ FKM | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3-5C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Standard | Body diaphragm: PEEK \/ Kalrez | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3-5CP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Standard | Body diaphragm: PEEK \/ Kalrez | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3-5C1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Standard | Body diaphragm: PEEK \/ Kalrez | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3Y-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Low-power | Body diaphragm: PEEK \/ EPDM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3Y-5AP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Low-power | Body diaphragm: PEEK \/ EPDM | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3Y-5A1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Low-power | Body diaphragm: PEEK \/ EPDM | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3Y-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Low-power | Body diaphragm: PEEK \/ FKM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3Y-5BP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Low-power | Body diaphragm: PEEK \/ FKM | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3Y-5B1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Low-power | Body diaphragm: PEEK \/ FKM | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3Y-5C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Low-power | Body diaphragm: PEEK \/ Kalrez | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3Y-5CP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Low-power | Body diaphragm: PEEK \/ Kalrez | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R3Y-5C1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.C. | Circuit: Low-power | Body diaphragm: PEEK \/ Kalrez | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Standard | Body diaphragm: PEEK \/ EPDM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4-5AP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Standard | Body diaphragm: PEEK \/ EPDM | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4-5A1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Standard | Body diaphragm: PEEK \/ EPDM | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Standard | Body diaphragm: PEEK \/ FKM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4-5BP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Standard | Body diaphragm: PEEK \/ FKM | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4-5B1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Standard | Body diaphragm: PEEK \/ FKM | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4-5C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Standard | Body diaphragm: PEEK \/ Kalrez | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4-5CP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Standard | Body diaphragm: PEEK \/ Kalrez | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4-5C1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Standard | Body diaphragm: PEEK \/ Kalrez | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4Y-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Low-power | Body diaphragm: PEEK \/ EPDM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4Y-5AP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Low-power | Body diaphragm: PEEK \/ EPDM | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4Y-5A1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Low-power | Body diaphragm: PEEK \/ EPDM | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4Y-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Low-power | Body diaphragm: PEEK \/ FKM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4Y-5BP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Low-power | Body diaphragm: PEEK \/ FKM | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4Y-5B1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Low-power | Body diaphragm: PEEK \/ FKM | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4Y-5C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Low-power | Body diaphragm: PEEK \/ Kalrez | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4Y-5CP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Low-power | Body diaphragm: PEEK \/ Kalrez | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM20R4Y-5C1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 2-port N.O. | Circuit: Low-power | Body diaphragm: PEEK \/ Kalrez | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205R-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Standard | Body diaphragm: PEEK \/ EPDM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205R-5AP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Standard | Body diaphragm: PEEK \/ EPDM | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205R-5A1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Standard | Body diaphragm: PEEK \/ EPDM | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205R-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Standard | Body diaphragm: PEEK \/ FKM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205R-5BP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Standard | Body diaphragm: PEEK \/ FKM | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205R-5B1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Standard | Body diaphragm: PEEK \/ FKM | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205R-5C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Standard | Body diaphragm: PEEK \/ Kalrez | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205R-5CP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Standard | Body diaphragm: PEEK \/ Kalrez | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205R-5C1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Standard | Body diaphragm: PEEK \/ Kalrez | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205RY-5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Low-power | Body diaphragm: PEEK \/ EPDM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205RY-5AP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Low-power | Body diaphragm: PEEK \/ EPDM | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205RY-5A1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Low-power | Body diaphragm: PEEK \/ EPDM | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205RY-5B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Low-power | Body diaphragm: PEEK \/ FKM | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205RY-5BP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Low-power | Body diaphragm: PEEK \/ FKM | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205RY-5B1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Low-power | Body diaphragm: PEEK \/ FKM | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205RY-5C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Low-power | Body diaphragm: PEEK \/ Kalrez | Sub plate: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205RY-5CP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Low-power | Body diaphragm: PEEK \/ Kalrez | Sub plate: None, anti-reverse pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLVM205RY-5C1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePiping: Base mounted | Valve: 3-port Universal | Circuit: Low-power | Body diaphragm: PEEK \/ Kalrez | Sub plate: PVDF, Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521681850658,"sku":"LVM20","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-lvm20-200-compact-chemical-solenoid-valve.jpg?v=1791950363","url":"https:\/\/prosourcemro.com\/products\/smc-lvm20-200-compact-chemical-solenoid-valve","provider":"ProSource MRO","version":"1.0","type":"link"}