{"product_id":"smc-pf3w-digital-flow-switch-for-water","title":"SMC PF3W Digital Flow Switch for Water (3-Color Display)","description":"\u003cp class=\"ps-intro\"\u003eSMC PF3W series Karman-vortex digital flow switch for water and ethylene glycol, with 3-color 2-screen display or remote sensor unit, rated 0.5 to 250 L\/min, including PVC piping models.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eKarman vortex detection for water and ethylene glycol solution (viscosity 3 mPa.s or less), fluid 0 to 90 C\u003c\/li\u003e\n\u003cli\u003eFive rated flow ranges from 0.5-4 L\/min to 50-250 L\/min; flow adjust valve (S) on 4, 16 and 40 L\/min types\u003c\/li\u003e\n\u003cli\u003eIntegrated display: NPN\/PNP switch outputs with analog, external input or temperature sensor (T) options\u003c\/li\u003e\n\u003cli\u003eRemote sensor unit (PF3W5) with analog output for PFG200 \/ PF3W3 monitors\u003c\/li\u003e\n\u003cli\u003ePVC piping models (U25 \/ U30) for 100 and 250 L\/min; IP65, CE\/UKCA, UL (CSA)\u003c\/li\u003e\n\u003cli\u003eSuffix options not expanded: NPT\/G thread, lead wire omitted (N), bracket (R), calibration certificate (A), -X109\/-X128\/-X143\/-X445\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eWater, ethylene glycol solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection method\u003c\/th\u003e\n\u003ctd\u003eKarman vortex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 to 1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 90 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003eDisplay +\/-3% F.S., analog +\/-3% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003e+\/-2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eDC12 to 24 V +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd\u003e50 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWetted materials\u003c\/th\u003e\n\u003ctd\u003ePPS, SUS304, FKM, SCS13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog (SMCKR_PF3W.pdf), p. 11-13, 24-26 (PDF p. 12-14, 25-27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-AT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: NPN + NPN, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-BT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: PNP + PNP, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-CT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: NPN + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-DT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: NPN + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-ET-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: PNP + analog 1-5 V, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-FT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: PNP + analog 4-20 mA, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-JT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: Analog 1-5 V flow + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-KT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated display | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: Analog 4-20 mA flow + 4-20 mA temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W504-03-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W504-03-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W504-03-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W504S-03-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W504S-03-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W504S-03-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W520-03-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W520-03-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W520-03-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W520-04-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W520-04-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W520-04-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W520S-03-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W520S-03-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W520S-03-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W520S-04-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W520S-04-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W520S-04-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W540-04-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W540-04-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W540-04-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W540-06-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W540-06-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W540-06-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W540S-04-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W540S-04-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W540S-04-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W540S-06-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W540S-06-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W540S-06-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W511-06-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W511-06-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W511-06-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W511-10-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W511-10-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W511-10-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W521-12-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W521-12-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W521-12-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W521-14-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W521-14-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W521-14-1T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor unit | Rated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: Analog 1-5 V + 1-5 V temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-U25-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: PVC tube 25A (OD 32 mm) | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-U25-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: PVC tube 25A (OD 32 mm) | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-U25-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: PVC tube 25A (OD 32 mm) | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-U25-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: PVC tube 25A (OD 32 mm) | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-U25-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: PVC tube 25A (OD 32 mm) | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-U25-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: PVC tube 25A (OD 32 mm) | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-U25-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: PVC tube 25A (OD 32 mm) | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-U25-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: PVC tube 25A (OD 32 mm) | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W511-U25-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor, PVC piping | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: PVC tube 25A (OD 32 mm) | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W511-U25-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor, PVC piping | Rated flow: 10-100 L\/min | Flow adjust valve: None | Port: PVC tube 25A (OD 32 mm) | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-U30-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 30-250 L\/min | Flow adjust valve: None | Port: PVC tube 30A (OD 38 mm) | Output: NPN + NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-U30-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 30-250 L\/min | Flow adjust valve: None | Port: PVC tube 30A (OD 38 mm) | Output: PNP + PNP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-U30-C-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 30-250 L\/min | Flow adjust valve: None | Port: PVC tube 30A (OD 38 mm) | Output: NPN + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-U30-D-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 30-250 L\/min | Flow adjust valve: None | Port: PVC tube 30A (OD 38 mm) | Output: NPN + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-U30-E-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 30-250 L\/min | Flow adjust valve: None | Port: PVC tube 30A (OD 38 mm) | Output: PNP + analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-U30-F-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 30-250 L\/min | Flow adjust valve: None | Port: PVC tube 30A (OD 38 mm) | Output: PNP + analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-U30-G-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 30-250 L\/min | Flow adjust valve: None | Port: PVC tube 30A (OD 38 mm) | Output: NPN + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-U30-H-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Integrated, PVC piping | Rated flow: 30-250 L\/min | Flow adjust valve: None | Port: PVC tube 30A (OD 38 mm) | Output: PNP + external input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W521-U30-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor, PVC piping | Rated flow: 30-250 L\/min | Flow adjust valve: None | Port: PVC tube 30A (OD 38 mm) | Output: Analog 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W521-U30-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eType: Remote sensor, PVC piping | Rated flow: 30-250 L\/min | Flow adjust valve: None | Port: PVC tube 30A (OD 38 mm) | Output: Analog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521663959330,"sku":"PF3W","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-pf3w-digital-flow-switch-for-water.jpg?v=1791950392","url":"https:\/\/prosourcemro.com\/products\/smc-pf3w-digital-flow-switch-for-water","provider":"ProSource MRO","version":"1.0","type":"link"}