{"product_id":"smc-pf3w7-l-io-link-digital-flow-switch-for-water","title":"SMC PF3W7-L IO-Link Digital Flow Switch for Water (Integrated)","description":"\u003cp class=\"ps-intro\"\u003eSMC PF3W7-L series IO-Link compatible integrated-display digital flow switch for water, rated 0.5 to 250 L\/min, with optional temperature sensor.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eIO-Link device (V1.1, COM2) with switch output (N\/P); temperature sensor type (LT) outputs flow or temperature\u003c\/li\u003e\n\u003cli\u003eFive rated ranges 0.5-4 to 50-250 L\/min; flow adjust valve (S) on 4\/16\/40 L\/min types\u003c\/li\u003e\n\u003cli\u003e0.5-100 L\/min models use the lightweight Z body; 250 L\/min model uses the standard body\u003c\/li\u003e\n\u003cli\u003eSuffix options not expanded: lead wire omitted (N), M12-M8 conversion lead (Q), bracket (R), calibration certificate (A)\u003c\/li\u003e\n\u003cli\u003eL2 \/ L2T two-output types are made to order\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eWater, ethylene glycol solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eIO-Link V1.1, COM2 (38.4 kbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eDC12 to 24 V (switch), DC18 to 30 V (IO-Link)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. applied voltage\u003c\/th\u003e\n\u003ctd\u003e30 V (NPN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 to 1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eCE, UKCA, UL (CSA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog CAT.KS100-133B (SMCKR_PF3W-Z_PF3W-L.pdf), p. 15-16 (PDF p. 16-17)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-L-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704-03-LT-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 0.5-4 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-L-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W704S-03-LT-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 0.5-4 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-L-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-03-LT-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc3\/8 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-L-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720-04-LT-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 2-16 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-L-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-03-LT-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/8 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-L-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W720S-04-LT-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 2-16 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-L-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-04-LT-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc1\/2 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-L-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740-06-LT-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 5-40 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-L-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-04-LT-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc1\/2 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-L-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W740S-06-LT-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 5-40 L\/min | Flow adjust valve: With flow adjust valve | Port: Rc3\/4 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-L-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-06-LT-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc3\/4 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-L-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W711-10-LT-MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 10-100 L\/min | Flow adjust valve: None | Port: Rc1 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-L-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-12-LT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/4 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-L-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: IO-Link\/switch, no temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF3W721-14-LT-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRated flow: 50-250 L\/min | Flow adjust valve: None | Port: Rc1 1\/2 | Output: IO-Link\/switch, temp sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521664287010,"sku":"PF3W7-L","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-pf3w7-l-io-link-digital-flow-switch-for-water.jpg?v=1791950391","url":"https:\/\/prosourcemro.com\/products\/smc-pf3w7-l-io-link-digital-flow-switch-for-water","provider":"ProSource MRO","version":"1.0","type":"link"}