{"product_id":"smc-pfuw-clamp-on-flow-sensor","title":"SMC PFUW Clamp-On Flow Sensor (Liquid, IO-Link, 60 to 200 L\/min)","description":"\u003cp class=\"ps-intro\"\u003eSMC PFUW series ultrasonic clamp-on flow sensor for liquids that mounts on the outside of the pipe with no piping work, leakage, pressure loss or fluid contact.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eUltrasonic transit-time detection; clamps onto 15A, 20A and 25A metal or rigid resin pipes\u003c\/li\u003e\n\u003cli\u003eRated flow ranges 0 to 60, 0 to 100 and 0 to 200 L\/min; accumulated flow and zero cut\u003c\/li\u003e\n\u003cli\u003eOUT1 IO-Link\/NPN\/PNP plus OUT2 switch\/external input, analog voltage or 4-20 mA\u003c\/li\u003e\n\u003cli\u003eIP65\/IP67 enclosure; 3-screen color LCD rotatable 90\/180\/270°\u003c\/li\u003e\n\u003cli\u003eM12 lead wire 3 m standard (N: none, Q: M12-M12 lead); calibration certificate option A\u003c\/li\u003e\n\u003cli\u003eSpare clamp assemblies ZS-57-60LR\/11LR\/21LR and rubber sheet ZS-57-A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eLiquids (water, oil, chemicals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 90°C (no condensation or freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection\u003c\/th\u003e\n\u003ctd\u003eUltrasonic (transit-time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay accuracy\u003c\/th\u003e\n\u003ctd\u003e±3.0% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003e±2.0% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e18 to 30 VDC, 85 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP65\/IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMass\u003c\/th\u003e\n\u003ctd\u003eBody 165 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eCE\/UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog CAT.KS100-167A (SMCKR_PFUW.pdf), PDF p. 8-9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW760-L1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 60 L\/min | Pipe size: 15A (1\/2B) | Output: IO-Link\/NPN\/PNP | Units: Unit selection function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW760-L1-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 60 L\/min | Pipe size: 15A (1\/2B) | Output: IO-Link\/NPN\/PNP | Units: SI units only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW760-L2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 60 L\/min | Pipe size: 15A (1\/2B) | Output: IO-Link\/NPN\/PNP + NPN\/PNP\/ext. input | Units: Unit selection function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW760-L2-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 60 L\/min | Pipe size: 15A (1\/2B) | Output: IO-Link\/NPN\/PNP + NPN\/PNP\/ext. input | Units: SI units only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW760-L3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 60 L\/min | Pipe size: 15A (1\/2B) | Output: IO-Link\/NPN\/PNP + analog voltage | Units: Unit selection function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW760-L3-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 60 L\/min | Pipe size: 15A (1\/2B) | Output: IO-Link\/NPN\/PNP + analog voltage | Units: SI units only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW760-L4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 60 L\/min | Pipe size: 15A (1\/2B) | Output: IO-Link\/NPN\/PNP + analog 4-20 mA | Units: Unit selection function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW760-L4-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 60 L\/min | Pipe size: 15A (1\/2B) | Output: IO-Link\/NPN\/PNP + analog 4-20 mA | Units: SI units only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW711-L1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 100 L\/min | Pipe size: 20A (3\/4B) | Output: IO-Link\/NPN\/PNP | Units: Unit selection function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW711-L1-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 100 L\/min | Pipe size: 20A (3\/4B) | Output: IO-Link\/NPN\/PNP | Units: SI units only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW711-L2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 100 L\/min | Pipe size: 20A (3\/4B) | Output: IO-Link\/NPN\/PNP + NPN\/PNP\/ext. input | Units: Unit selection function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW711-L2-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 100 L\/min | Pipe size: 20A (3\/4B) | Output: IO-Link\/NPN\/PNP + NPN\/PNP\/ext. input | Units: SI units only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW711-L3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 100 L\/min | Pipe size: 20A (3\/4B) | Output: IO-Link\/NPN\/PNP + analog voltage | Units: Unit selection function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW711-L3-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 100 L\/min | Pipe size: 20A (3\/4B) | Output: IO-Link\/NPN\/PNP + analog voltage | Units: SI units only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW711-L4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 100 L\/min | Pipe size: 20A (3\/4B) | Output: IO-Link\/NPN\/PNP + analog 4-20 mA | Units: Unit selection function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW711-L4-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 100 L\/min | Pipe size: 20A (3\/4B) | Output: IO-Link\/NPN\/PNP + analog 4-20 mA | Units: SI units only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW721-L1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 200 L\/min | Pipe size: 25A (1B) | Output: IO-Link\/NPN\/PNP | Units: Unit selection function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW721-L1-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 200 L\/min | Pipe size: 25A (1B) | Output: IO-Link\/NPN\/PNP | Units: SI units only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW721-L2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 200 L\/min | Pipe size: 25A (1B) | Output: IO-Link\/NPN\/PNP + NPN\/PNP\/ext. input | Units: Unit selection function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW721-L2-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 200 L\/min | Pipe size: 25A (1B) | Output: IO-Link\/NPN\/PNP + NPN\/PNP\/ext. input | Units: SI units only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW721-L3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 200 L\/min | Pipe size: 25A (1B) | Output: IO-Link\/NPN\/PNP + analog voltage | Units: Unit selection function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW721-L3-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 200 L\/min | Pipe size: 25A (1B) | Output: IO-Link\/NPN\/PNP + analog voltage | Units: SI units only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW721-L4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 200 L\/min | Pipe size: 25A (1B) | Output: IO-Link\/NPN\/PNP + analog 4-20 mA | Units: Unit selection function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFUW721-L4-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow range: 0 to 200 L\/min | Pipe size: 25A (1B) | Output: IO-Link\/NPN\/PNP + analog 4-20 mA | Units: SI units only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521665630498,"sku":"PFUW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-pfuw-clamp-on-flow-sensor.jpg?v=1791950394","url":"https:\/\/prosourcemro.com\/products\/smc-pfuw-clamp-on-flow-sensor","provider":"ProSource MRO","version":"1.0","type":"link"}