{"product_id":"smc-ppa-compact-manometer","title":"SMC PPA Compact Manometer (PPA100\/101\/102, Battery Powered)","description":"\u003cp class=\"ps-intro\"\u003eSMC PPA series handheld digital compact manometer for checking air line and regulator set pressures, powered by two AA batteries.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003ePalm-size portable unit of about 100 g (body 50 g, batteries 50 g)\u003c\/li\u003e\n\u003cli\u003eThree ranges: PPA100 high pressure, PPA101 vacuum, PPA102 low pressure\u003c\/li\u003e\n\u003cli\u003eUpper\/lower peak display, backlight, auto power OFF, zero clear and unit display switching\u003c\/li\u003e\n\u003cli\u003eOptional one-touch fitting for ø4 or ø6 tube (KQ2H04\/06-M5N) and PPA-B case holder\u003c\/li\u003e\n\u003cli\u003eAbout 12 months continuous operation on two AA batteries (batteries not included)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir, non-corrosive gas, non-flammable gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eBacklit 3-digit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003ePPA100 1.5 MPa; PPA101\/102 200 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e3 VDC, AA battery x2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse time\u003c\/th\u003e\n\u003ctd\u003e250 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S. or less (25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003e±1% F.S. or less (25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePort size\u003c\/th\u003e\n\u003ctd\u003eM5x0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0 to 50°C (no freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eCE\/UKCA marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog PPA Series (SMCKR_PPA.pdf), p. 1309 (PDF p. 1-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA100 high pressure -0.1 to 1 MPa | One-touch fitting: None (M5 female port) | Case holder: None | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA100-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA100 high pressure -0.1 to 1 MPa | One-touch fitting: None (M5 female port) | Case holder: None | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA100-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA100 high pressure -0.1 to 1 MPa | One-touch fitting: None (M5 female port) | Case holder: PPA-B case holder | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA100-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA100 high pressure -0.1 to 1 MPa | One-touch fitting: None (M5 female port) | Case holder: PPA-B case holder | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA100-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA100 high pressure -0.1 to 1 MPa | One-touch fitting: KQ2H04-M5N for ø4 tube | Case holder: None | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA100-04-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA100 high pressure -0.1 to 1 MPa | One-touch fitting: KQ2H04-M5N for ø4 tube | Case holder: None | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA100-04-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA100 high pressure -0.1 to 1 MPa | One-touch fitting: KQ2H04-M5N for ø4 tube | Case holder: PPA-B case holder | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA100-04-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA100 high pressure -0.1 to 1 MPa | One-touch fitting: KQ2H04-M5N for ø4 tube | Case holder: PPA-B case holder | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA100-06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA100 high pressure -0.1 to 1 MPa | One-touch fitting: KQ2H06-M5N for ø6 tube | Case holder: None | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA100-06-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA100 high pressure -0.1 to 1 MPa | One-touch fitting: KQ2H06-M5N for ø6 tube | Case holder: None | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA100-06-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA100 high pressure -0.1 to 1 MPa | One-touch fitting: KQ2H06-M5N for ø6 tube | Case holder: PPA-B case holder | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA100-06-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA100 high pressure -0.1 to 1 MPa | One-touch fitting: KQ2H06-M5N for ø6 tube | Case holder: PPA-B case holder | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA101\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA101 vacuum -101 to 10 kPa | One-touch fitting: None (M5 female port) | Case holder: None | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA101-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA101 vacuum -101 to 10 kPa | One-touch fitting: None (M5 female port) | Case holder: None | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA101-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA101 vacuum -101 to 10 kPa | One-touch fitting: None (M5 female port) | Case holder: PPA-B case holder | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA101-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA101 vacuum -101 to 10 kPa | One-touch fitting: None (M5 female port) | Case holder: PPA-B case holder | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA101-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA101 vacuum -101 to 10 kPa | One-touch fitting: KQ2H04-M5N for ø4 tube | Case holder: None | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA101-04-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA101 vacuum -101 to 10 kPa | One-touch fitting: KQ2H04-M5N for ø4 tube | Case holder: None | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA101-04-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA101 vacuum -101 to 10 kPa | One-touch fitting: KQ2H04-M5N for ø4 tube | Case holder: PPA-B case holder | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA101-04-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA101 vacuum -101 to 10 kPa | One-touch fitting: KQ2H04-M5N for ø4 tube | Case holder: PPA-B case holder | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA101-06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA101 vacuum -101 to 10 kPa | One-touch fitting: KQ2H06-M5N for ø6 tube | Case holder: None | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA101-06-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA101 vacuum -101 to 10 kPa | One-touch fitting: KQ2H06-M5N for ø6 tube | Case holder: None | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA101-06-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA101 vacuum -101 to 10 kPa | One-touch fitting: KQ2H06-M5N for ø6 tube | Case holder: PPA-B case holder | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA101-06-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA101 vacuum -101 to 10 kPa | One-touch fitting: KQ2H06-M5N for ø6 tube | Case holder: PPA-B case holder | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA102\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA102 low pressure -10 to 100 kPa | One-touch fitting: None (M5 female port) | Case holder: None | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA102-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA102 low pressure -10 to 100 kPa | One-touch fitting: None (M5 female port) | Case holder: None | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA102-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA102 low pressure -10 to 100 kPa | One-touch fitting: None (M5 female port) | Case holder: PPA-B case holder | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA102-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA102 low pressure -10 to 100 kPa | One-touch fitting: None (M5 female port) | Case holder: PPA-B case holder | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA102-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA102 low pressure -10 to 100 kPa | One-touch fitting: KQ2H04-M5N for ø4 tube | Case holder: None | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA102-04-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA102 low pressure -10 to 100 kPa | One-touch fitting: KQ2H04-M5N for ø4 tube | Case holder: None | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA102-04-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA102 low pressure -10 to 100 kPa | One-touch fitting: KQ2H04-M5N for ø4 tube | Case holder: PPA-B case holder | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA102-04-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA102 low pressure -10 to 100 kPa | One-touch fitting: KQ2H04-M5N for ø4 tube | Case holder: PPA-B case holder | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA102-06\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA102 low pressure -10 to 100 kPa | One-touch fitting: KQ2H06-M5N for ø6 tube | Case holder: None | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA102-06-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA102 low pressure -10 to 100 kPa | One-touch fitting: KQ2H06-M5N for ø6 tube | Case holder: None | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA102-06-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA102 low pressure -10 to 100 kPa | One-touch fitting: KQ2H06-M5N for ø6 tube | Case holder: PPA-B case holder | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPA102-06-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModel: PPA102 low pressure -10 to 100 kPa | One-touch fitting: KQ2H06-M5N for ø6 tube | Case holder: PPA-B case holder | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521659076898,"sku":"PPA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-ppa-compact-manometer.jpg?v=1791950391","url":"https:\/\/prosourcemro.com\/products\/smc-ppa-compact-manometer","provider":"ProSource MRO","version":"1.0","type":"link"}