{"product_id":"smc-sy-5-port-solenoid-valve-plug-in-subplate-ip67","title":"SMC SY Plug-in Solenoid Valve with Subplate (IP67, M12 Connector)","description":"\u003cp class=\"ps-intro\"\u003eSMC SY3000\/5000\/7000 plug-in 5-port solenoid valve supplied mounted on an individual IP67 subplate with M12 waterproof connector, side or bottom ported.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eValve plus single subplate, connected by M12 waterproof connector; IP67 (IEC60529)\u003c\/li\u003e\n\u003cli\u003eSubplate ports P, A, B, EA, EB: Rc1\/8 (SY3000), Rc1\/4 (SY5000), Rc3\/8 (SY7000), individual EA\/EB exhaust\u003c\/li\u003e\n\u003cli\u003eSwitching: 2-position single\/double, 3-position closed\/exhaust\/pressure center, 4-position dual 3-port (rubber seal only)\u003c\/li\u003e\n\u003cli\u003eListed codes: DC24V\/DC12V with light and surge suppressor (U non-polar, Z +COM), M12 cable none\/0.3\/0.5\/1 m\u003c\/li\u003e\n\u003cli\u003eM12 cable 2 m (W4) or 5 m (W7), top-ported valve (V), external pilot, power-saving, locking manual and G\/NPT\/NPTF threads on order\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve type\u003c\/th\u003e\n\u003ctd\u003ePilot-operated 5-port, plug-in, on individual subplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003ctd\u003eM12 waterproof connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThread type\u003c\/th\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure (internal pilot)\u003c\/th\u003e\n\u003ctd\u003eRubber seal: 0.15-0.7 MPa single, 0.1-0.7 double, 0.2-0.7 3-pos; metal seal 0.1-0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient and fluid temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to 50°C (no freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpact\/vibration resistance\u003c\/th\u003e\n\u003ctd\u003e150\/30 m\/s²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAllowable voltage fluctuation\u003c\/th\u003e\n\u003ctd\u003e±10% of rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog SY3000\/5000\/7000 (SMCKR_SY3000_5000_7000.pdf), p. 694-696 (PDF p. 338-340)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3100-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3101-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3200-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3201-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3300-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3301-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3400-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3401-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3500-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3501-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3A00-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3B00-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-5Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6U1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6U1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6U1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6U1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6U1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6U1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6U1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6U1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6Z1-WO-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6Z1-WO-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6Z1-W1-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6Z1-W1-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6Z1-W2-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6Z1-W2-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6Z1-W3-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY3C00-6Z1-W3-B01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY3000 (Rc1\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5100-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5101-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5200-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5201-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5300-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5301-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5400-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5401-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5500-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5501-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5A00-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5B00-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-5Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6U1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6U1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6U1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6U1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6U1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6U1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6U1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6U1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6Z1-WO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6Z1-WO-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6Z1-W1-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6Z1-W1-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6Z1-W2-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6Z1-W2-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6Z1-W3-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY5C00-6Z1-W3-B02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY5000 (Rc1\/4) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7100-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7101-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos single | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7200-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7201-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 2-pos double | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7300-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7301-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos closed center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7400-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7401-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos exhaust center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7500-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7501-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 3-pos pressure center | Seal: Metal seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7A00-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.C. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7B00-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.O.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-5Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC24V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6U1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6U1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6U1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6U1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6U1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6U1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6U1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6U1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, non-polar | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6Z1-WO-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6Z1-WO-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: No cable | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6Z1-W1-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6Z1-W1-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 300 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6Z1-W2-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6Z1-W2-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 500 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6Z1-W3-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Side ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY7C00-6Z1-W3-B03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: SY7000 (Rc3\/8) | Switching: 4-pos dual 3-port N.C.\/N.O. | Seal: Rubber seal | Coil: DC12V, Light\/surge, +COM | M12 cable: 1000 mm | Piping: Bottom ported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521555693858,"sku":"SY","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-sy-5-port-solenoid-valve-plug-in-subplate-ip67.jpg?v=1791950394","url":"https:\/\/prosourcemro.com\/products\/smc-sy-5-port-solenoid-valve-plug-in-subplate-ip67","provider":"ProSource MRO","version":"1.0","type":"link"}