{"product_id":"smc-sy100-3-port-solenoid-valve-direct-operated","title":"SMC SY100 3-Port Solenoid Valve (Direct Operated, 10 mm Width)","description":"\u003cp class=\"ps-intro\"\u003eSMC SY100 series direct-operated 3-port solenoid valve with rubber seal, 10 mm body width, N.C. or N.O., in standard and high-flow versions for direct or base piping.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eLow power consumption 0.5 W (standard type, without lamp); high-flow type 0.75 W\u003c\/li\u003e\n\u003cli\u003eUsable for vacuum down to -100 kPa (10 Torr)\u003c\/li\u003e\n\u003cli\u003eStandard type effective area 0.14 mm², high-flow type (A) 0.22 mm²\u003c\/li\u003e\n\u003cli\u003eCopper-free wetted parts; grommet (G\/H), L or M plug connector entry; listed codes cover G, L and M\u003c\/li\u003e\n\u003cli\u003eLamp\/surge suppressor (S, Z, R, U), manual override (B, D, E), bracket (F) and CE\/UKCA (Q) ordered as suffixes\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure range\u003c\/th\u003e\n\u003ctd\u003e0 to 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient and fluid temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to 50°C (no freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse time\u003c\/th\u003e\n\u003ctd\u003e10 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. operating frequency\u003c\/th\u003e\n\u003ctd\u003e20 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePort size\u003c\/th\u003e\n\u003ctd\u003eM3x0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil rated voltage\u003c\/th\u003e\n\u003ctd\u003eDC 24, 12, 6, 5, 3 V; AC 100, 110, 200, 220 V (standard type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpact\/vibration resistance\u003c\/th\u003e\n\u003ctd\u003e150\/30 m\/s²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eDustproof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog SY100 (SMCKR_SY100.pdf), p. 1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-5G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-5G-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-5G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-5L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-5L-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-5L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-5M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-5M-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-5M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-6G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-6G-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-6G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-6L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-6L-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-6L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-6M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-6M-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-6M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-1G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: AC100V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-1G-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: AC100V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: AC100V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-1G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: AC100V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-1L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: AC100V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-1L-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: AC100V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: AC100V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-1L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: AC100V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-1M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: AC100V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-1M-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: AC100V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: AC100V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-1M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: AC100V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-2G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: AC200V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-2G-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: AC200V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: AC200V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-2G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: AC200V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-2L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: AC200V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-2L-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: AC200V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: AC200V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-2L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: AC200V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-2M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: AC200V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113-2M-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: AC200V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: AC200V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114-2M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: AC200V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-5G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-5G-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-5G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-5L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-5L-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-5L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-5M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-5M-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-5M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-6G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-6G-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-6G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-6L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-6L-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-6L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-6M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-6M-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-6M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-1G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: AC100V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-1G-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: AC100V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: AC100V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-1G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: AC100V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-1L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: AC100V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-1L-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: AC100V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: AC100V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-1L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: AC100V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-1M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: AC100V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-1M-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: AC100V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: AC100V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-1M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: AC100V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-2G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: AC200V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-2G-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: AC200V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: AC200V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-2G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: AC200V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-2L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: AC200V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-2L-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: AC200V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: AC200V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-2L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: AC200V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-2M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, for 30\/31 manifold | Voltage: AC200V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123-2M-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: AC200V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, without sub-plate | Voltage: AC200V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124-2M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: Standard (Cv 0.008) | Piping: Base piping, with sub-plate M3 | Voltage: AC200V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113A-5G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113A-5G-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Base piping, without sub-plate | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114A-5G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Base piping, with sub-plate M3 | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113A-5L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113A-5L-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114A-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Base piping, without sub-plate | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114A-5L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Base piping, with sub-plate M3 | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113A-5M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113A-5M-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114A-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Base piping, without sub-plate | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114A-5M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Base piping, with sub-plate M3 | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113A-6G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113A-6G-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114A-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Base piping, without sub-plate | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114A-6G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Base piping, with sub-plate M3 | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113A-6L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113A-6L-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114A-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Base piping, without sub-plate | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114A-6L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Base piping, with sub-plate M3 | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113A-6M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY113A-6M-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114A-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Base piping, without sub-plate | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY114A-6M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.C. | Flow type: High flow (Cv 0.012) | Piping: Base piping, with sub-plate M3 | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123A-5G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123A-5G-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Base piping, without sub-plate | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124A-5G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Base piping, with sub-plate M3 | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123A-5L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123A-5L-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124A-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Base piping, without sub-plate | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124A-5L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Base piping, with sub-plate M3 | Voltage: DC24V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123A-5M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123A-5M-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124A-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Base piping, without sub-plate | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124A-5M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Base piping, with sub-plate M3 | Voltage: DC24V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123A-6G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123A-6G-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124A-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Base piping, without sub-plate | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124A-6G-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Base piping, with sub-plate M3 | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123A-6L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123A-6L-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124A-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Base piping, without sub-plate | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124A-6L-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Base piping, with sub-plate M3 | Voltage: DC12V | Electrical entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123A-6M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, for 30\/31 manifold | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY123A-6M-PM3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Direct piping, P\/R\/A ports M3 | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124A-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Base piping, without sub-plate | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSY124A-6M-M3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching: N.O. | Flow type: High flow (Cv 0.012) | Piping: Base piping, with sub-plate M3 | Voltage: DC12V | Electrical entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521558839586,"sku":"SY100","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-sy100-3-port-solenoid-valve-direct-operated.jpg?v=1791950394","url":"https:\/\/prosourcemro.com\/products\/smc-sy100-3-port-solenoid-valve-direct-operated","provider":"ProSource MRO","version":"1.0","type":"link"}