{"product_id":"smc-vfn200n-namur-3-port-solenoid-valve","title":"SMC VFN200N 3-Port Solenoid Valve (NAMUR Interface)","description":"\u003cp class=\"ps-intro\"\u003eSMC VFN200N series pilot-operated 3-port N.C. solenoid valve with NAMUR-compliant interface for direct mounting on industrial valve actuators.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eNAMUR interface: mounts directly on rotary valve actuators with two bolts\u003c\/li\u003e\n\u003cli\u003eSingle or double solenoid, elastic seal, 1\/4 ports (Rc standard; G (F) and NPT (N) on order)\u003c\/li\u003e\n\u003cli\u003eElectrical entry: grommet, grommet terminal, conduit terminal or DIN terminal (DIN 43650 Form B for Y)\u003c\/li\u003e\n\u003cli\u003eOptions: Z light\/surge suppressor, S surge suppressor (grommet), manual override A (push, extended) \/ B (locking, tool), CE (Q)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValve type\u003c\/th\u003e\n\u003ctd\u003eNormally closed, pilot operated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0.15 to 0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient and fluid temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePort size\u003c\/th\u003e\n\u003ctd\u003eRc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow (P to A)\u003c\/th\u003e\n\u003ctd\u003eC 2.68 dm³\/(s·bar), Cv 0.72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAllowable voltage fluctuation\u003c\/th\u003e\n\u003ctd\u003e-15% to +10% of rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003eDC 1.8 W; AC 2.3 VA (60 Hz) holding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMass\u003c\/th\u003e\n\u003ctd\u003e240 g (single), 380 g (double)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog VFN (SMCKR_VFN.pdf), p. 189-191 (PDF p. 1-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1G-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC100V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1E-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC100V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1T-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC100V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1D-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC100V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1DO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC100V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1Y-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC100V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1YO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC100V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2G-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC200V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2E-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC200V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2T-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC200V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2D-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC200V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2DO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC200V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2Y-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC200V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2YO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC200V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3G-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC110-120V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3E-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC110-120V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3T-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC110-120V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3D-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC110-120V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3DO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC110-120V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3Y-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC110-120V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3YO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC110-120V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4G-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC220V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4E-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC220V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4T-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC220V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4D-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC220V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4DO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC220V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4Y-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC220V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4YO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC220V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5G-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5E-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC24V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5T-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC24V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5D-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC24V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5DO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC24V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5Y-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC24V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5YO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC24V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6G-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6E-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC12V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6T-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC12V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6D-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC12V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6DO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC12V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6Y-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC12V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6YO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: DC12V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7G-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC240V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7E-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC240V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7T-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC240V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7D-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC240V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7DO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC240V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7Y-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC240V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7YO-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Single | Voltage: AC240V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1G-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC100V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1E-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC100V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1T-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC100V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1D-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC100V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1DO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC100V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1Y-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC100V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-1YO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC100V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2G-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC200V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2E-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC200V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2T-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC200V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2D-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC200V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2DO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC200V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2Y-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC200V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-2YO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC200V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3G-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC110-120V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3E-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC110-120V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3T-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC110-120V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3D-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC110-120V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3DO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC110-120V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3Y-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC110-120V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-3YO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC110-120V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4G-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC220V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4E-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC220V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4T-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC220V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4D-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC220V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4DO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC220V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4Y-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC220V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-4YO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC220V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5G-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC24V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5E-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC24V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5T-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC24V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5D-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC24V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5DO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC24V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5Y-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC24V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-5YO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC24V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6G-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC12V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6E-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC12V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6T-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC12V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6D-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC12V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6DO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC12V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6Y-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC12V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-6YO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: DC12V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7G-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC240V | Electrical entry: Grommet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7E-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC240V | Electrical entry: Grommet terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7T-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC240V | Electrical entry: Conduit terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7D-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC240V | Electrical entry: DIN terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7DO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC240V | Electrical entry: DIN terminal, no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7Y-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC240V | Electrical entry: DIN terminal (Form B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFN212N-7YO-02-D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSolenoid: Double | Voltage: AC240V | Electrical entry: DIN (Form B), no connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521791000866,"sku":"VFN200N","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-vfn200n-namur-3-port-solenoid-valve.jpg?v=1791950420","url":"https:\/\/prosourcemro.com\/products\/smc-vfn200n-namur-3-port-solenoid-valve","provider":"ProSource MRO","version":"1.0","type":"link"}