{"product_id":"smc-vna-2-port-process-valve-air-hydro","title":"SMC VNA 2-Port Process Valve (Air \/ Air-Hydro, 6A to 50A)","description":"\u003cp class=\"ps-intro\"\u003eSMC VNA series balanced-poppet 2-port process valve for compressed air and air-hydro circuits, cylinder-actuated by external pilot air, in air operated and external pilot solenoid versions from 6A to 50A.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eBalanced poppet construction allows flow in either direction and operation from atmospheric pressure\u003c\/li\u003e\n\u003cli\u003eN.C., N.O. and C.O. (double acting, air operated only) valve types in seven sizes, orifice ø10 to ø50\u003c\/li\u003e\n\u003cli\u003eSeal materials NBR (air, N2, turbine\/hydraulic oil), FKM (argon, helium, oils) and EPDM (CO2 0.7 MPa or more)\u003c\/li\u003e\n\u003cli\u003eListed solenoid codes: AC100V, AC200V, AC220V, DC24V with grommet, grommet + surge suppressor, DIN terminal and DIN with lamp\/surge suppressor\u003c\/li\u003e\n\u003cli\u003eGrommet terminal (E\/EZ), conduit terminal (T\/TZ), manual override A\/B, bracket (B), G\/NPT\/NPTF threads and CE\/UKCA (-Q) on order\u003c\/li\u003e\n\u003cli\u003ePilot solenoid valve SF4 (sizes 1 to 4) or VO307 (sizes 5 to 7)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir, N2, CO2, turbine oil, hydraulic oil (not for water)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure range\u003c\/th\u003e\n\u003ctd\u003e0 to 1 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExternal pilot air pressure\u003c\/th\u003e\n\u003ctd\u003e0.2 to 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid temperature\u003c\/th\u003e\n\u003ctd\u003e-5 to 60°C (NBR), -5 to 99°C (FKM\/EPDM, air operated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 to 50°C (air operated 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePort thread\u003c\/th\u003e\n\u003ctd\u003eRc (G, NPT, NPTF on order)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting orientation\u003c\/th\u003e\n\u003ctd\u003eUnrestricted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eNot required (turbine oil ISO VG32 if used)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot valve power\u003c\/th\u003e\n\u003ctd\u003eSF4: 1.8 W DC; VO307: 4 W DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog VNA (SMCKR_VNA.pdf), p. 560-562 (PDF p. 2-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA101A-6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA101B-6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA101C-6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA102A-6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA102B-6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA102C-6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA103A-6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: C.O. (double acting) | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA103B-6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: C.O. (double acting) | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA103C-6A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: C.O. (double acting) | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA101A-8A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA101B-8A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA101C-8A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA102A-8A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA102B-8A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA102C-8A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA103A-8A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: C.O. (double acting) | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA103B-8A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: C.O. (double acting) | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA103C-8A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: C.O. (double acting) | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA101A-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA101B-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA101C-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA102A-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA102B-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA102C-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA103A-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: C.O. (double acting) | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA103B-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: C.O. (double acting) | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA103C-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: C.O. (double acting) | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA201A-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA201B-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA201C-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA202A-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA202B-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA202C-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA203A-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: C.O. (double acting) | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA203B-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: C.O. (double acting) | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA203C-10A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: C.O. (double acting) | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA201A-15A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA201B-15A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA201C-15A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA202A-15A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA202B-15A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA202C-15A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA203A-15A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: C.O. (double acting) | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA203B-15A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: C.O. (double acting) | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA203C-15A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: C.O. (double acting) | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA301A-20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA301B-20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA301C-20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA302A-20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA302B-20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA302C-20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA303A-20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: C.O. (double acting) | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA303B-20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: C.O. (double acting) | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA303C-20A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: C.O. (double acting) | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA401A-25A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA401B-25A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA401C-25A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA402A-25A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA402B-25A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA402C-25A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA403A-25A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: C.O. (double acting) | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA403B-25A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: C.O. (double acting) | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA403C-25A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: C.O. (double acting) | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA501A-32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA501B-32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA501C-32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA502A-32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA502B-32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA502C-32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA503A-32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: C.O. (double acting) | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA503B-32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: C.O. (double acting) | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA503C-32A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: C.O. (double acting) | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA601A-40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA601B-40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA601C-40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA602A-40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA602B-40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA602C-40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA603A-40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: C.O. (double acting) | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA603B-40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: C.O. (double acting) | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA603C-40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: C.O. (double acting) | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA701A-50A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA701B-50A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA701C-50A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA702A-50A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA702B-50A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA702C-50A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA703A-50A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: C.O. (double acting) | Seal: NBR | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA703B-50A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: C.O. (double acting) | Seal: FKM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA703C-50A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: C.O. (double acting) | Seal: EPDM | Operation: Air operated (no coil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-6A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-6A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-6A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-6A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-6A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-6A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/8 (6A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-8A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-8A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-8A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-8A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-8A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-8A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc1\/4 (8A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111A-10A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111B-10A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA111C-10A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112A-10A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112B-10A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA112C-10A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA1 (orifice ø10) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-10A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-10A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-10A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-10A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-10A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-10A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc3\/8 (10A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211A-15A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211B-15A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA211C-15A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212A-15A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212B-15A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA212C-15A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA2 (orifice ø15) | Port: Rc1\/2 (15A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311A-20A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311B-20A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA311C-20A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312A-20A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312B-20A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA312C-20A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA3 (orifice ø20) | Port: Rc3\/4 (20A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411A-25A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411B-25A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA411C-25A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412A-25A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412B-25A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA412C-25A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA4 (orifice ø25) | Port: Rc1 (25A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511A-32A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511B-32A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA511C-32A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512A-32A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512B-32A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA512C-32A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA5 (orifice ø32) | Port: Rc1-1\/4 (32A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611A-40A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611B-40A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA611C-40A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612A-40A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612B-40A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA612C-40A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA6 (orifice ø40) | Port: Rc1-1\/2 (40A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711A-50A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711B-50A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA711C-50A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.C. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712A-50A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: NBR | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712B-50A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: FKM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-1GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-1D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-1DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC100V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-2GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-2D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-2DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC200V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-4GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-4D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-4DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid AC220V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet (G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-5GS\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, grommet+surge (GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-5D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN terminal (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVNA712C-50A-5DZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSize: VNA7 (orifice ø50) | Port: Rc2 (50A) | Valve type: N.O. | Seal: EPDM | Operation: Solenoid DC24V, DIN+lamp\/surge (DZ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521673134370,"sku":"VNA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-vna-2-port-process-valve-air-hydro.jpg?v=1791950421","url":"https:\/\/prosourcemro.com\/products\/smc-vna-2-port-process-valve-air-hydro","provider":"ProSource MRO","version":"1.0","type":"link"}