{"product_id":"smc-vpa-3-port-air-operated-valve","title":"SMC VPA300\/500\/700 3-Port Air Operated Valve and VV3PA Manifold","description":"\u003cp class=\"ps-intro\"\u003eSMC VPA300\/500\/700 series air-piloted 3-port poppet valve for 0.2 to 1.0 MPa or vacuum, as direct piping or base piping single units and on VV3PA manifolds.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eThree body sizes with Rc1\/8 to Rc1\/2 ports; N.C. or N.O. (switching type convertible)\u003c\/li\u003e\n\u003cli\u003eStandard type 0.2 to 1.0 MPa; vacuum type (V) -100 kPa to 0.2 MPa\u003c\/li\u003e\n\u003cli\u003eBase piping valves listed with Rc sub-plate or without sub-plate (gasket and 2 mounting bolts included)\u003c\/li\u003e\n\u003cli\u003eVV3PA manifolds: type 41 common exhaust or type 42 individual exhaust, 2 to 20 stations, common supply\u003c\/li\u003e\n\u003cli\u003eBracket (-F, direct piping), G\/NPT\/NPTF threads and X505 old-mounting-pitch version on order; blanking plate VP300\/500\/700-25-1A\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValve type\u003c\/th\u003e\n\u003ctd\u003e3-port air operated valve, poppet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure range\u003c\/th\u003e\n\u003ctd\u003eStandard 0.2 to 1.0 MPa; vacuum -100 kPa to 0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot pressure\u003c\/th\u003e\n\u003ctd\u003e0.2 to 1.0 MPa (not less than operating pressure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient and fluid temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to 50°C (no freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting orientation\u003c\/th\u003e\n\u003ctd\u003eUnrestricted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpact\/vibration resistance\u003c\/th\u003e\n\u003ctd\u003e300\/50 m\/s²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot port (12\/PA)\u003c\/th\u003e\n\u003ctd\u003eRc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow rate C (1→2) [dm³\/(s·bar)]\u003c\/th\u003e\n\u003ctd\u003eVPA342 3.5-4.2, VPA542 7.9-8.9, VPA742 11.9-15.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManifold valves\u003c\/th\u003e\n\u003ctd\u003eVPA344 \/ VPA544 \/ VPA744 (order separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog VPA300\/500\/700 (SMCKR_VPA.pdf), p. 1360, 1366, 1371-1372 (PDF p. 4, 10, 15-16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA342-1-01A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Direct piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA342-1-02A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Direct piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA344-1-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Without sub-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA344-1-01A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Rc1\/8 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA344-1-02A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Rc1\/4 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA342-1-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Direct piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA342-1-02B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Direct piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA344-1-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Without sub-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA344-1-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Rc1\/8 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA344-1-02B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Rc1\/4 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA342V-1-01A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Direct piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA342V-1-02A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Direct piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA344V-1-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Without sub-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA344V-1-01A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Rc1\/8 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA344V-1-02A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Rc1\/4 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA342V-1-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Direct piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA342V-1-02B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Direct piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA344V-1-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Without sub-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA344V-1-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Rc1\/8 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA344V-1-02B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Rc1\/4 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA542-1-02A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Direct piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA542-1-03A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Direct piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA544-1-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Without sub-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA544-1-02A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Rc1\/4 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA544-1-03A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Rc3\/8 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA542-1-02B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Direct piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA542-1-03B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Direct piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA544-1-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Without sub-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA544-1-02B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Rc1\/4 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA544-1-03B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Rc3\/8 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA542V-1-02A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Direct piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA542V-1-03A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Direct piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA544V-1-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Without sub-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA544V-1-02A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Rc1\/4 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA544V-1-03A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Rc3\/8 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA542V-1-02B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Direct piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA542V-1-03B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Direct piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA544V-1-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Without sub-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA544V-1-02B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Rc1\/4 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA544V-1-03B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Rc3\/8 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA742-1-03A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Direct piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA742-1-04A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Direct piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA744-1-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Without sub-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA744-1-03A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Rc3\/8 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA744-1-04A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.C. | Port size: Rc1\/2 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA742-1-03B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Direct piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA742-1-04B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Direct piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA744-1-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Without sub-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA744-1-03B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Rc3\/8 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA744-1-04B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Base piping valve | Option \/ stations: Standard | Switching: N.O. | Port size: Rc1\/2 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA742V-1-03A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Direct piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA742V-1-04A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Direct piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA744V-1-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Without sub-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA744V-1-03A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Rc3\/8 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA744V-1-04A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.C. | Port size: Rc1\/2 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA742V-1-03B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Direct piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA742V-1-04B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Direct piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA744V-1-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Without sub-plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA744V-1-03B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Rc3\/8 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPA744V-1-04B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Base piping valve | Option \/ stations: Vacuum | Switching: N.O. | Port size: Rc1\/2 (sub-plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-021-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 2 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-031-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 3 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-041-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 4 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-051-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 5 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-061-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 6 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-071-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 7 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-081-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 8 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-091-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 9 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-101-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 10 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-111-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 11 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-121-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 12 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-131-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 13 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-141-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 14 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-151-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 15 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-161-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 16 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-171-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 17 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-181-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 18 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-191-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 19 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-41-201-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 41 common exhaust | Option \/ stations: 20 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-023-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 2 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-033-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 3 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-043-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 4 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-053-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 5 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-063-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 6 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-073-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 7 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-083-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 8 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-093-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 9 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-103-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 10 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-113-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 11 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-123-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 12 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-133-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 13 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-143-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 14 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-153-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 15 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-163-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 16 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-173-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 17 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-183-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 18 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-193-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 19 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA3-42-203-02\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA300 | Type: Manifold 42 individual exh. | Option \/ stations: 20 stations | Switching: Per mounted valve | Port size: Rc1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-021-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 2 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-031-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 3 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-041-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 4 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-051-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 5 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-061-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 6 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-071-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 7 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-081-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 8 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-091-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 9 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-101-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 10 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-111-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 11 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-121-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 12 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-131-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 13 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-141-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 14 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-151-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 15 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-161-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 16 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-171-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 17 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-181-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 18 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-191-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 19 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-41-201-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 41 common exhaust | Option \/ stations: 20 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-023-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 2 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-033-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 3 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-043-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 4 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-053-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 5 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-063-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 6 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-073-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 7 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-083-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 8 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-093-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 9 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-103-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 10 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-113-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 11 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-123-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 12 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-133-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 13 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-143-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 14 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-153-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 15 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-163-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 16 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-173-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 17 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-183-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 18 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-193-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 19 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA5-42-203-03\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA500 | Type: Manifold 42 individual exh. | Option \/ stations: 20 stations | Switching: Per mounted valve | Port size: Rc3\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-021-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 2 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-031-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 3 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-041-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 4 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-051-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 5 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-061-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 6 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-071-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 7 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-081-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 8 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-091-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 9 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-101-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 10 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-111-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 11 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-121-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 12 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-131-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 13 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-141-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 14 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-151-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 15 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-161-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 16 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-171-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 17 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-181-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 18 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-191-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 19 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-41-201-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 41 common exhaust | Option \/ stations: 20 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-023-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 2 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-033-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 3 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-043-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 4 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-053-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 5 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-063-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 6 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-073-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 7 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-083-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 8 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-093-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 9 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-103-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 10 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-113-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 11 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-123-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 12 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-133-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 13 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-143-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 14 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-153-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 15 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-163-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 16 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-173-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 17 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-183-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 18 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-193-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 19 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVV3PA7-42-203-04\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: VPA700 | Type: Manifold 42 individual exh. | Option \/ stations: 20 stations | Switching: Per mounted valve | Port size: Rc1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521563820322,"sku":"VPA300","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-vpa-3-port-air-operated-valve.jpg?v=1791950420","url":"https:\/\/prosourcemro.com\/products\/smc-vpa-3-port-air-operated-valve","provider":"ProSource MRO","version":"1.0","type":"link"}