{"product_id":"smc-xla-high-vacuum-l-type-valve","title":"SMC XLA High Vacuum L-Type Valve (Aluminum, N.C., Bellows, 16-160)","description":"\u003cp class=\"ps-intro\"\u003eSMC XLA normally closed, air-operated aluminum high vacuum angle (L-type) valve with bellows seal, in flange sizes 16 to 160.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eAluminum body: light, compact, uniform baking temperature, low outgassing and low heavy-metal contamination\u003c\/li\u003e\n\u003cli\u003eSizes 16-80 (design -2) have a replaceable bellows assembly to cut maintenance cost\u003c\/li\u003e\n\u003cli\u003eNormally closed, opened by pilot pressure, closed by spring; SUS316L bellows seal\u003c\/li\u003e\n\u003cli\u003eOptional open indicator, heaters for 100\/120 C body heating (H4\/H5) and high-temperature build to 150 C (H0)\u003c\/li\u003e\n\u003cli\u003eAuto switch (D-M9N\/M9P\/M9B\/A90\/A93, 1 or 2 pcs) is an order suffix, not expanded\u003c\/li\u003e\n\u003cli\u003eSeal material change (EPDM, Kalrez, Chemraz, VMQ, ULTIC ARMOR etc.) via -X suffix\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve type\u003c\/th\u003e\n\u003ctd\u003eNormally closed, pressurize to open, spring seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eInert gas under vacuum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBody material\u003c\/th\u003e\n\u003ctd\u003eAluminum alloy (A6063)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurface treatment\u003c\/th\u003e\n\u003ctd\u003eHard anodized outside, untreated inside\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e1x10^-6 Pa(abs) to atmospheric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConductance\u003c\/th\u003e\n\u003ctd\u003eL\/s: 16=5, 25=14, 40=45, 50=80, 63=160, 80=200, 100=300, 160=800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLeakage (FKM)\u003c\/th\u003e\n\u003ctd\u003eInternal 1.3x10^-10, external 1.3x10^-11 Pa m3\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot pressure\u003c\/th\u003e\n\u003ctd\u003e0.4-0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot port\u003c\/th\u003e\n\u003ctd\u003eM5 (16-50), Rc1\/8 (63-100), Rc1\/4 (160)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlange\u003c\/th\u003e\n\u003ctd\u003eKF (NW) all sizes; K (DN) for 63, 80, 100, 160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea XL catalogs (SMCKR_XL-2.pdf p. 4, 6; SMCKR_XL.pdf p. 2, 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16H0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16A-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16AH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16FH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16GH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16J-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16JH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16K-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16KH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16L-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16LH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16M-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-16MH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25H0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25H5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25A-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25AH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25AH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25FH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25FH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25GH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25GH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25J-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25JH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25JH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25K-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25KH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25KH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25L-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25LH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25LH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25M-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25MH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-25MH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40H0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40H4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40H5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40A-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40AH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40AH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40AH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40FH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40FH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40FH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40GH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40GH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40GH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40J-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40JH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40JH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40JH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40K-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40KH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40KH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40KH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40L-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40LH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40LH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40LH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40M-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40MH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40MH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-40MH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50H0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50H4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50H5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50A-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50AH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50AH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50AH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50FH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50FH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50FH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50GH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50GH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50GH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50J-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50JH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50JH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50JH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50K-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50KH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50KH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50KH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50L-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50LH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50LH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50LH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50M-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50MH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50MH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-50MH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63H0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63H4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63H5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63A-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63AH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63AH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63AH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63FH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63FH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63FH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63GH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63GH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63GH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63J-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63JH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63JH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63JH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63K-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63KH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63KH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63KH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63L-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63LH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63LH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63LH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63M-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63MH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63MH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63MH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63D-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DA-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DAH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DAH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DAH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DF-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DFH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DFH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DFH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DGH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DGH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DGH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DJ-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DJH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DJH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DJH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DK-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DKH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DKH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DKH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DL-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DLH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DLH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DLH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DM-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DMH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DMH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-63DMH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80H0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80H4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80H5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80A-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80AH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80AH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80AH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80FH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80FH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80FH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80GH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80GH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80GH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80J-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80JH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80JH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80JH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80K-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80KH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80KH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80KH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80L-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80LH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80LH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80LH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80M-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80MH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80MH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80MH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80D-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DA-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DAH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DAH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DAH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DF-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DFH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DFH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DFH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DGH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DGH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DGH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DJ-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DJH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DJH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DJH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DK-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DKH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DKH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DKH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DL-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DLH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DLH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DLH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DM-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DMH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DMH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-80DMH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100H4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100H5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100AH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100AH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100FH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100FH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100GH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100GH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100GH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100JH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100JH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100KH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100KH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100LH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100LH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100LH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100MH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100MH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DAH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DAH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DAH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DFH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DFH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DFH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DG\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DGH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DGH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DGH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DJ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DJH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DJH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DJH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DKH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DKH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DKH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DLH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DLH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DLH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DMH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DMH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-100DMH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160H4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160H5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160AH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160AH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160FH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160FH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160GH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160GH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160GH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160JH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160JH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160KH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160KH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160LH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160LH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160LH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160MH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160MH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DAH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DAH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DAH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DFH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DFH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DFH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DG\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DGH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DGH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DGH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DJ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DJH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DJH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DJH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DKH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DKH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DKH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DLH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DLH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DLH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DMH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DMH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLA-160DMH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521741652258,"sku":"XLA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-xla-high-vacuum-l-type-valve.jpg?v=1791950423","url":"https:\/\/prosourcemro.com\/products\/smc-xla-high-vacuum-l-type-valve","provider":"ProSource MRO","version":"1.0","type":"link"}