{"product_id":"smc-xlf-high-vacuum-l-type-valve","title":"SMC XLF High Vacuum L-Type Valve (N.C., O-Ring Seal, 16-160)","description":"\u003cp class=\"ps-intro\"\u003eSMC XLF normally closed, air-operated aluminum high vacuum L-type valve with O-ring shaft seal, flange sizes 16 to 160.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eO-ring shaft seal (no bellows) for a simple, economical construction\u003c\/li\u003e\n\u003cli\u003eNormally closed, pressurize to open, spring return\u003c\/li\u003e\n\u003cli\u003eOptional open indicator, heaters (H4\/H5) and high-temperature build to 150 C (H0)\u003c\/li\u003e\n\u003cli\u003eAuto switch (D-M9N\/M9P\/M9B\/A90\/A93, 1 or 2 pcs) is an order suffix, not expanded\u003c\/li\u003e\n\u003cli\u003eSeal material change (EPDM, Kalrez, Chemraz, VMQ, ULTIC ARMOR etc.) via -X suffix\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve type\u003c\/th\u003e\n\u003ctd\u003eNormally closed, pressurize to open, spring seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eInert gas under vacuum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBody material\u003c\/th\u003e\n\u003ctd\u003eAluminum alloy (A6063)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurface treatment\u003c\/th\u003e\n\u003ctd\u003eHard anodized outside, untreated inside\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e1x10^-5 Pa(abs) to atmospheric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConductance\u003c\/th\u003e\n\u003ctd\u003eL\/s: 16=5, 25=14, 40=45, 50=80, 63=160, 80=200, 100=300, 160=800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLeakage (FKM)\u003c\/th\u003e\n\u003ctd\u003eInternal and external 1.3x10^-10 Pa m3\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot pressure\u003c\/th\u003e\n\u003ctd\u003e0.4-0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea XL catalogs (SMCKR_XL-2.pdf p. 11, 13; SMCKR_XL.pdf p. 16, 18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16H0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16A-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16AH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16FH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16GH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16J-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16JH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16K-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16KH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16L-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16LH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16M-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-16MH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25H0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25H5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25A-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25AH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25AH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25FH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25FH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25GH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25GH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25J-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25JH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25JH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25K-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25KH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25KH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25L-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25LH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25LH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25M-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25MH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-25MH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40H0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40H4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40H5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40A-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40AH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40AH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40AH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40FH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40FH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40FH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40GH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40GH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40GH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40J-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40JH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40JH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40JH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40K-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40KH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40KH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40KH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40L-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40LH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40LH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40LH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40M-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40MH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40MH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-40MH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50H0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50H4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50H5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50A-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50AH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50AH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50AH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50FH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50FH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50FH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50GH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50GH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50GH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50J-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50JH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50JH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50JH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50K-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50KH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50KH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50KH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50L-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50LH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50LH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50LH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50M-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50MH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50MH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-50MH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63H0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63H4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63H5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63A-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63AH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63AH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63AH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63FH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63FH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63FH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63GH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63GH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63GH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63J-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63JH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63JH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63JH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63K-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63KH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63KH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63KH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63L-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63LH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63LH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63LH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63M-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63MH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63MH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63MH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63D-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DA-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DAH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DAH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DAH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DF-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DFH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DFH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DFH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DGH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DGH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DGH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DJ-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DJH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DJH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DJH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DK-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DKH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DKH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DKH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DL-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DLH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DLH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DLH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DM-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DMH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DMH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-63DMH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80H0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80H4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80H5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80A-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80AH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80AH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80AH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80FH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80FH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80FH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80G-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80GH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80GH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80GH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80J-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80JH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80JH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80JH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80K-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80KH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80KH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80KH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80L-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80LH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80LH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80LH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80M-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80MH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80MH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80MH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80D-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DA-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DAH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DAH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DAH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DF-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DFH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DFH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DFH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DGH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DGH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DGH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DJ-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DJH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DJH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DJH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DK-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DKH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DKH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DKH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DL-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DLH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DLH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DLH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DM-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DMH0-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DMH4-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-80DMH5-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100H4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100H5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100AH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100AH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100FH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100FH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100GH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100GH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100GH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100JH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100JH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100KH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100KH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100LH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100LH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100LH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100MH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100MH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DAH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DAH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DAH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DFH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DFH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DFH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DG\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DGH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DGH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DGH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DJ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DJH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DJH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DJH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DKH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DKH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DKH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DLH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DLH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DLH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DMH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DMH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-100DMH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 100 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160H4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160H5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160AH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160AH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160FH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160FH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160GH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160GH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160GH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160JH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160JH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160KH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160KH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160LH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160LH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160LH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160MH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160MH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DAH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DAH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DAH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DFH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DFH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DFH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DG\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DGH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DGH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DGH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DJ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DJH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DJH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DJH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DKH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DKH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DKH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DLH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DLH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DLH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DMH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp, no heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DMH4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 100 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLF-160DMH5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 160 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C, 120 C heater fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521744077090,"sku":"XLF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-xlf-high-vacuum-l-type-valve.jpg?v=1791950423","url":"https:\/\/prosourcemro.com\/products\/smc-xlf-high-vacuum-l-type-valve","provider":"ProSource MRO","version":"1.0","type":"link"}