{"product_id":"smc-xlfv-high-vacuum-l-type-valve-solenoid-16-80","title":"SMC XLFV High Vacuum L-Type Valve with Solenoid Valve (16-80)","description":"\u003cp class=\"ps-intro\"\u003eSMC XLFV aluminum high vacuum L-type valve, normally closed with O-ring seal and a directly mounted pilot solenoid valve, flange sizes 16 to 80.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eO-ring shaft seal valve with pilot solenoid valve mounted on the actuator\u003c\/li\u003e\n\u003cli\u003ePilot solenoid valve mounted on the actuator: supply pilot air to 1(P) and switch electrically\u003c\/li\u003e\n\u003cli\u003eCoil voltages AC100\/110\/200\/220V and DC12\/24V; grommet or L\/M plug connector lead entry\u003c\/li\u003e\n\u003cli\u003eLamp\/surge suppressor (S\/Z\/U) and CE\/UKCA (Q) are suffix options, not expanded\u003c\/li\u003e\n\u003cli\u003eAuto switch (D-M9N\/M9P\/M9B\/A90\/A93, 1 or 2 pcs) is an order suffix, not expanded\u003c\/li\u003e\n\u003cli\u003eSeal material change (EPDM, Kalrez, Chemraz, VMQ, ULTIC ARMOR etc.) via -X suffix\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve type\u003c\/th\u003e\n\u003ctd\u003eNormally closed, O-ring seal, solenoid pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eInert gas under vacuum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBody material\u003c\/th\u003e\n\u003ctd\u003eAluminum alloy (A6063)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurface treatment\u003c\/th\u003e\n\u003ctd\u003eHard anodized outside, untreated inside\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e5-50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e1x10^-5 Pa(abs) to atmospheric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConductance\u003c\/th\u003e\n\u003ctd\u003eL\/s: 16=5, 25=14, 40=45, 50=80, 63=160, 80=200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot pressure\u003c\/th\u003e\n\u003ctd\u003e0.4-0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea XL catalog (SMCKR_XL-2.pdf), p. 12-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16F-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16G-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16J-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16K-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16L-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-16M-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 16 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25F-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25G-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25J-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25K-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25L-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-25M-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 25 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40F-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40G-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40J-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40K-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40L-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-40M-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 40 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50F-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50G-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50J-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50K-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50L-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-50M-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 50 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63F-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63G-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63J-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63K-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63L-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63M-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DF-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DG-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DJ-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DK-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DL-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-63DM-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 63 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80F-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80G-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80J-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80K-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80L-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80M-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: KF (NW) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DF-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DG-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DJ-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: Indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DK-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve left | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DL-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve rear | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-1G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-1H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-1L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-1M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC100V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-2G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-2H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-2L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-2M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC200V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-3G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-3H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-3L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-3M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC110V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-4G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-4M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: AC220V 50\/60Hz | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-5G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-5H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-5L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-5M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC24V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-6G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 300 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: Grommet, 600 mm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: L-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXLFV-80DM-2-6M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange size: 80 | Flange type: K (DN) | Indicator and valve: No indicator, valve right | Coil voltage: DC12V | Lead wire entry: M-type plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521744240930,"sku":"XLFV","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-xlfv-high-vacuum-l-type-valve-solenoid-16-80.jpg?v=1791950423","url":"https:\/\/prosourcemro.com\/products\/smc-xlfv-high-vacuum-l-type-valve-solenoid-16-80","provider":"ProSource MRO","version":"1.0","type":"link"}