{"product_id":"smc-xma-xya-stainless-high-vacuum-valve","title":"SMC XMA\/XYA Stainless High Vacuum Valve (L\/Straight, N.C., Bellows)","description":"\u003cp class=\"ps-intro\"\u003eSMC XMA (L-type) and XYA (straight type) normally closed stainless steel high vacuum valves with bellows seal.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eOne-piece precision-cast SCS13 stainless body with no gas trap\u003c\/li\u003e\n\u003cli\u003eXMA mounting compatible with the aluminum XL series\u003c\/li\u003e\n\u003cli\u003eKF (NW), K (DN) and CF (conflat) flanges on XMA; KF and K on XYA\u003c\/li\u003e\n\u003cli\u003eHigh-temperature version to 150 C (H0)\u003c\/li\u003e\n\u003cli\u003eAuto switch (D-M9N\/M9P\/M9B\/A90\/A93, 1 or 2 pcs) is an order suffix, not expanded\u003c\/li\u003e\n\u003cli\u003eSeal material change (EPDM, Kalrez, Chemraz, VMQ, ULTIC ARMOR etc.) via -X suffix\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve type\u003c\/th\u003e\n\u003ctd\u003eN.C., pressurize to open, spring seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eInert gas under vacuum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBody material\u003c\/th\u003e\n\u003ctd\u003eStainless steel SCS13 (SUS304 equiv.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBellows\u003c\/th\u003e\n\u003ctd\u003eSUS316L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e1x10^-6 Pa(abs) to atmospheric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLeakage (FKM)\u003c\/th\u003e\n\u003ctd\u003eInternal 1.3x10^-10, external 1.3x10^-11 Pa m3\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConductance\u003c\/th\u003e\n\u003ctd\u003eL\/s: 16=5, 25=14, 40=45, 50=80, 63=160, 80=200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot pressure\u003c\/th\u003e\n\u003ctd\u003e0.4-0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea XM\/XY catalog (SMCKR_XM_XY.pdf), p. 3-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16GH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16LH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CAH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CFH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CG\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CGH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CJ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CJH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CKH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CLH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-16CMH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 16 | Flange type: CF (conflat) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25GH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25LH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-25MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40GH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40LH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CAH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CFH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CG\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CGH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CJ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CJH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CKH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CLH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-40CMH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 40 | Flange type: CF (conflat) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50GH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50LH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-50MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63GH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63LH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DAH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DFH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DG\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DGH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DJ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DJH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DKH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DLH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63DMH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63C\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CAH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CFH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CG\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CGH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CJ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CJH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CKH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CLH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-63CMH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 63 | Flange type: CF (conflat) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80GH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80LH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DAH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port flange side | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DFH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DG\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DGH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DJ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DJH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DKH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DLH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXMA-80DMH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: L-type (XMA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-25H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-25A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-25AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-25F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-25FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-25J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-25JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-25K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-25KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-25M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-25MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 25 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-40H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-40A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-40AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-40F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-40FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-40J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-40JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-40K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-40KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-40M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-40MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 40 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-50\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-50H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-50A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-50AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-50F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-50FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-50J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-50JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-50K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-50KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-50M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-50MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 50 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63DH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63DA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63DAH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63DF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63DFH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63DJ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63DJH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63DK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63DKH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63DM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-63DMH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 63 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80H0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80AH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80F\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80FH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80J\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80JH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80KH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80MH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: KF (NW) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80DH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80DA\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80DAH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port rear | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80DF\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80DFH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80DJ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80DJH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: Indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80DK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80DKH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port left | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80DM\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-60 C standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXYA-80DMH0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBody: Straight (XYA) | Flange size: 80 | Flange type: K (DN) | Indicator and port: No indicator, port right | Temperature: 5-150 C high temp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521749713186,"sku":"XMA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-xma-xya-stainless-high-vacuum-valve.jpg?v=1791950424","url":"https:\/\/prosourcemro.com\/products\/smc-xma-xya-stainless-high-vacuum-valve","provider":"ProSource MRO","version":"1.0","type":"link"}