{"product_id":"smc-zl1-multistage-ejector","title":"SMC ZL1 Multistage Vacuum Ejector (100 L\/min)","description":"\u003cp class=\"ps-intro\"\u003eSMC ZL1 multistage vacuum ejector with 100 L\/min (ANR) max. suction flow, optional supply\/release valves and vacuum pressure switch, gauge or detection port.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eMultistage diffuser ejector, nozzle ø1.2 mm, max. vacuum -84 kPa, air consumption 57 L\/min (ANR)\u003c\/li\u003e\n\u003cli\u003eLightweight 180 g (conventional ZL112: 450 g); interchangeable mounting with ZL112 (bottom adapter option B)\u003c\/li\u003e\n\u003cli\u003eSupply valve N.C.\/N.O. with or without release valve (SYJ500 type pilot), DC24V M plug connector with light\/surge suppressor in listed codes\u003c\/li\u003e\n\u003cli\u003eVacuum pressure switch with NPN\/PNP 2 outputs plus copy, analog voltage or analog current output, lead wire with connector 2 m\u003c\/li\u003e\n\u003cli\u003eOther voltages (DC12\/6\/5\/3V, AC100\/200\/110\/220V), grommet\/L plug leads, lock manual (D), inch fittings (N), G\/NPT exhaust ports on order\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNozzle diameter\u003c\/th\u003e\n\u003ctd\u003e1.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard supply pressure\u003c\/th\u003e\n\u003ctd\u003e0.33 MPa (no valve), 0.35 MPa (with valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. vacuum pressure\u003c\/th\u003e\n\u003ctd\u003e-84 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. suction flow\u003c\/th\u003e\n\u003ctd\u003e100 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir consumption\u003c\/th\u003e\n\u003ctd\u003e57 L\/min (ANR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply pressure range\u003c\/th\u003e\n\u003ctd\u003e0.2 to 0.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e5 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePorts\u003c\/th\u003e\n\u003ctd\u003eSupply ø6, vacuum ø12 one-touch fittings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog ZL1\/ZL3\/ZL6 CAT.KS100-108E (SMCKR_ZL1_ZL3_ZL6.pdf), p. 9-10 (PDF p. 10-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Detection port Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Pressure gauge (kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-DXL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-DXML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-DYL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-DYML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-DRL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-DRML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-DSL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-DSML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-DTL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-DTML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-DVL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-DVML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Detection port Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Pressure gauge (kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-DXL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-DXML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-DYL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-DYML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-DRL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-DRML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-DSL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-DSML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-DTL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-DTML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-DVL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K15MZ-DVML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Detection port Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Pressure gauge (kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-DXL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-DXML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-DYL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-DYML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-DRL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-DRML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-DSL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-DSML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-DTL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-DTML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-DVL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-K25MZ-DVML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Detection port Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Pressure gauge (kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-DXL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-DXML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-DYL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-DYML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-DRL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-DRML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-DSL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-DSML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-DTL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-DTML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-DVL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B15MZ-DVML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Detection port Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Pressure gauge (kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-DXL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-DXML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-DYL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-DYML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-DRL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-DRML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-DSL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-DSML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-DTL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-DTML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-DVL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112A-B25MZ-DVML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Silencer exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Detection port Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Pressure gauge (kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-DXL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-DXML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-DYL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-DYML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-DRL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-DRML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-DSL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-DSML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Switch NPN 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-DTL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-DTML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-DVL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-DVML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: None | Vacuum detection: Switch PNP 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Detection port Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Pressure gauge (kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-DXL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-DXML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-DYL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-DYML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-DRL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-DRML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-DSL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-DSML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-DTL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-DTML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-DVL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K15MZ-DVML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Detection port Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Pressure gauge (kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-DXL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-DXML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-DYL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-DYML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-DRL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-DRML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-DSL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-DSML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-DTL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-DTML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-DVL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-K25MZ-DVML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Detection port Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Pressure gauge (kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-DXL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-DXML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-DYL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-DYML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-DRL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-DRML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-DSL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-DSML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-DTL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-DTML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-DVL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B15MZ-DVML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. + release N.C. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-GN\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Detection port Rc1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Pressure gauge (kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-DXL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-DXML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-DYL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + copy, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-DYML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + copy, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-DRL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-DRML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-DSL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-DSML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch NPN 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-DTL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog V, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-DTML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog V, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-DVL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog I, switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZL112AP-B25MZ-DVML\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExhaust: Rc1\/2 port exhaust | Valves: Supply N.O. | Vacuum detection: Switch PNP 2 out + analog I, SI fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521621885218,"sku":"ZL1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-zl1-multistage-ejector.jpg?v=1791950423","url":"https:\/\/prosourcemro.com\/products\/smc-zl1-multistage-ejector","provider":"ProSource MRO","version":"1.0","type":"link"}