{"product_id":"smc-zq-a-thin-vacuum-unit-vacuum-pump-system","title":"SMC ZQ-A Thin Vacuum Unit, Vacuum Pump System (Single and Manifold)","description":"\u003cp class=\"ps-intro\"\u003eSMC ZQ-A series 10.2 mm thin vacuum unit for vacuum pump systems (ZQ000), as single units, manifold-use units and ZZQ1 manifold bases.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eVacuum switching (supply) valve, release valve, release flow needle, suction filter and vacuum pressure switch in a 10.2 mm wide body\u003c\/li\u003e\n\u003cli\u003eValve combinations K1, K2, J1, J2, Q1, Q2 (N.C., N.O., latching supply valve; with or without release valve); IO-Link switch with K1\/K2\u003c\/li\u003e\n\u003cli\u003eSwitches: ZSE10 vacuum\/compound pressure switch, filter only (F) or IO-Link switch; lead wire with connector included in listed codes\u003c\/li\u003e\n\u003cli\u003eSingle-unit codes list matched PV\/PS fittings with V port; manifold-use units list V port fitting only\u003c\/li\u003e\n\u003cli\u003eZZQ1 manifold base for 1 to 8 stations with PV port left or right and common or separate release (PD) supply\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e5 to 50°C (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVacuum supply (PV) port\u003c\/th\u003e\n\u003ctd\u003e0 to -101.3 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot supply (PS) port\u003c\/th\u003e\n\u003ctd\u003e0.3 to 0.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelease supply (PD) port\u003c\/th\u003e\n\u003ctd\u003e0 to 0.45 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow, vacuum side (V to PV)\u003c\/th\u003e\n\u003ctd\u003eC 0.31 dm³\/(s·bar), Cv 0.09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow, release side (PS to V)\u003c\/th\u003e\n\u003ctd\u003eC 0.24 dm³\/(s·bar), Cv 0.08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain valve response time\u003c\/th\u003e\n\u003ctd\u003e25 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValve coil voltage\u003c\/th\u003e\n\u003ctd\u003eDC24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBody width\u003c\/th\u003e\n\u003ctd\u003e10.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog CAT.KS100-139A (SMCKR_ZQ__A.pdf), p. 5, 5-1, 6, 7 (PDF p. 9-12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EAG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EAG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EAG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EAG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EAG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EAG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EAG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EAG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EAG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EAG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EAG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EAG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EAG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EAG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EAG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EAG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EAG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EAG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EAG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EAG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EAG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EAG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EAG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EAG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EAMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EAMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EAMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EAMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EAMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EAMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EAMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EAMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EAMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EAMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EAMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EAMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EAMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EAMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EAMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EAMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EAMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EAMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EAMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EAMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EAMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EAMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EAMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EAMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EBG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EBG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EBG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EBG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EBG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EBG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EBG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EBG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EBG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EBG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EBG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EBG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EBG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EBG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EBG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EBG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EBG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EBG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EBG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EBG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EBG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EBG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EBG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EBG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EBMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EBMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EBMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EBMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EBMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EBMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EBMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EBMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EBMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EBMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EBMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EBMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EBMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EBMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EBMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EBMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EBMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EBMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EBMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EBMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EBMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EBMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EBMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EBMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-ECG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-ECG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-ECG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-ECG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-ECG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-ECG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-ECG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-ECG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-ECG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-ECG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-ECG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-ECG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-ECG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-ECG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-ECG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-ECG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-ECG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-ECG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-ECG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-ECG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-ECG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-ECG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-ECG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-ECG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-ECMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-ECMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-ECMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-ECMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-ECMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-ECMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-ECMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-ECMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-ECMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-ECMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-ECMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-ECMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-ECMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-ECMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-ECMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-ECMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-ECMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-ECMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-ECMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-ECMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-ECMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-ECMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-ECMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-ECMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EEG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EEG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EEG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EEG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EEG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EEG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EEG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EEG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EEG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EEG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EEG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EEG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EEG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EEG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EEG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EEG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EEG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EEG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EEG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EEG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EEG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EEG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EEG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EEG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EEMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EEMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EEMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-EEMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EEMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EEMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EEMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-EEMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EEMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EEMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EEMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-EEMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EEMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EEMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EEMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-EEMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EEMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EEMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EEMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-EEMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EEMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EEMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EEMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-EEMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FAG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FAG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FAG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FAG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FAG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FAG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FAG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FAG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FAG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FAG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FAG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FAG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FAG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FAG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FAG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FAG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FAG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FAG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FAG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FAG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FAG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FAG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FAG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FAG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FAMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FAMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FAMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FAMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FAMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FAMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FAMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FAMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FAMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FAMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FAMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FAMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FAMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FAMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FAMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FAMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FAMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FAMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FAMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FAMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FAMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FAMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FAMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FAMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FBG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FBG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FBG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FBG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FBG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FBG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FBG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FBG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FBG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FBG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FBG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FBG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FBG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FBG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FBG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FBG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FBG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FBG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FBG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FBG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FBG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FBG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FBG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FBG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FBMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FBMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FBMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FBMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FBMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FBMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FBMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FBMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FBMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FBMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FBMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FBMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FBMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FBMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FBMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FBMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FBMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FBMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FBMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FBMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FBMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FBMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FBMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FBMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FCG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FCG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FCG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FCG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FCG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FCG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FCG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FCG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FCG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FCG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FCG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FCG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FCG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FCG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FCG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FCG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FCG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FCG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FCG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FCG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FCG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FCG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FCG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FCG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FCMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FCMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FCMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FCMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FCMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FCMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FCMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FCMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FCMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FCMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FCMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FCMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FCMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FCMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FCMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FCMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FCMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FCMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FCMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FCMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FCMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FCMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FCMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FCMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FEG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FEG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FEG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FEG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FEG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FEG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FEG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FEG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FEG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FEG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FEG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FEG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FEG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FEG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FEG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FEG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FEG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FEG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FEG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FEG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FEG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FEG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FEG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FEG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FEMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FEMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FEMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-FEMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FEMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FEMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FEMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-FEMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FEMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FEMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FEMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-FEMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FEMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FEMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FEMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-FEMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FEMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FEMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FEMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-FEMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FEMG-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FEMG-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FEMG-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-FEMG-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-F-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-F-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-F-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15L-F-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-F-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-F-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-F-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25L-F-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-F-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-F-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-F-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J15L-F-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-F-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-F-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-F-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-J25L-F-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-F-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-F-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-F-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q15L-F-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-F-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-F-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-F-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-Q25L-F-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply latching, no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-ELH-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-ELH-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-ELH-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-ELH-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-ELH-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-ELH-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-ELH-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-ELH-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-ELMH-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-ELMH-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-ELMH-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-ELMH-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-ELMH-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-ELMH-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-ELMH-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-ELMH-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-FLH-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-FLH-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-FLH-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-FLH-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-FLH-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-FLH-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-FLH-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-FLH-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-FLMH-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-FLMH-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-FLMH-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K15LO-FLMH-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-FLMH-00\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: SI unit (kPa) fixed | Fittings: V M5 \/ P M5 (no fittings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-FLMH-22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-FLMH-33\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: SI unit (kPa) fixed | Fittings: V ø6 \/ P ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000UA-K25LO-FLMH-55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Single unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: SI unit (kPa) fixed | Fittings: V ø4 \/ P ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EAG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EAG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EAG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EAG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EAG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EAG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EAG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EAG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EAG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EAG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EAG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EAG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EAG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EAG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EAG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EAG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EAG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EAG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EAG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EAG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EAG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EAG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EAG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EAG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EAG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EAG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EAG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EAG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EAG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EAG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EAG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EAG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EAG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EAG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EAG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EAG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EBG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EBG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EBG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EBG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EBG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EBG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EBG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EBG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EBG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EBG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EBG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EBG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EBG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EBG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EBG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EBG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EBG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EBG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EBG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EBG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EBG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EBG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EBG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EBG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EBG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EBG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EBG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EBG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EBG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EBG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EBG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EBG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EBG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EBG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EBG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EBG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-ECG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-ECG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-ECG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-ECG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-ECG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-ECG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-ECG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-ECG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-ECG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-ECG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-ECG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-ECG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-ECG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-ECG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-ECG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-ECG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-ECG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-ECG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-ECG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-ECG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-ECG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-ECG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-ECG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-ECG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-ECG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-ECG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-ECG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-ECG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-ECG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-ECG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-ECG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-ECG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-ECG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-ECG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-ECG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-ECG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EEG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EEG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EEG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EEG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EEG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-EEG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EEG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EEG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EEG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EEG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EEG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-EEG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EEG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EEG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EEG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EEG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EEG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-EEG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EEG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EEG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EEG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EEG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EEG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-EEG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EEG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EEG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EEG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EEG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EEG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-EEG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EEG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EEG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EEG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EEG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EEG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-EEG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: 0 to -101 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FAG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FAG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FAG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FAG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FAG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FAG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FAG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FAG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FAG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FAG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FAG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FAG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FAG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FAG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FAG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FAG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FAG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FAG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FAG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FAG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FAG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FAG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FAG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FAG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FAG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FAG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FAG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FAG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FAG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FAG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FAG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FAG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FAG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FAG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FAG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FAG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FBG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FBG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FBG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FBG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FBG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FBG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FBG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FBG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FBG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FBG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FBG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FBG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FBG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FBG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FBG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FBG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FBG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FBG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FBG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FBG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FBG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FBG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FBG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FBG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FBG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FBG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FBG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FBG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FBG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FBG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FBG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FBG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FBG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FBG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FBG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FBG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 2 outputs | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FCG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FCG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FCG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FCG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FCG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FCG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FCG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FCG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FCG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FCG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FCG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FCG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FCG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FCG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FCG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FCG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FCG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FCG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FCG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FCG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FCG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FCG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FCG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FCG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FCG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FCG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FCG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FCG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FCG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FCG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FCG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FCG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FCG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FCG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FCG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FCG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, NPN 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FEG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FEG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FEG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FEG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FEG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-FEG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FEG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FEG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FEG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FEG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FEG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-FEG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FEG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FEG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FEG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FEG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FEG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-FEG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FEG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FEG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FEG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FEG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FEG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-FEG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FEG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FEG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FEG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FEG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FEG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-FEG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FEG-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FEG-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FEG-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FEG-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FEG-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-FEG-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: -100 to 100 kPa, PNP 1 out+analog | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-F-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-F-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-F-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-F-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15L-F-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-F-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-F-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-F-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-F-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25L-F-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-F-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-F-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-F-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-F-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J15L-F-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-F-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-F-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-F-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-F-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-J25L-F-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O., no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-F-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-F-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-F-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-F-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q15L-F-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching + release N.C. | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-F-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-F-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-F-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-F-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-F-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-Q25L-F-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply latching, no release valve | Pressure switch: Suction filter only (no switch) | Display unit: Not applicable | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15LO-ELH-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15LO-ELH-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15LO-ELH-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15LO-ELH-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15LO-ELH-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15LO-ELH-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25LO-ELH-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25LO-ELH-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25LO-ELH-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25LO-ELH-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25LO-ELH-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25LO-ELH-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link vacuum 0 to -101 kPa | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15LO-FLH-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15LO-FLH-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15LO-FLH-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15LO-FLH-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15LO-FLH-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K15LO-FLH-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.C. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25LO-FLH-0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V M5 (no fitting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25LO-FLH-1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø3.2 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25LO-FLH-2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø4 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25LO-FLH-3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø6 straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25LO-FLH-4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø3.2 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZQ000MA-K25LO-FLH-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold-use unit | Valves: Supply N.O. + release N.C. | Pressure switch: IO-Link compound -100 to 100 kPa | Display unit: Unit switching | Fittings: V ø4 elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ101A-LOB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 1 station | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ101A-LOC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 1 station | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ101A-ROB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 1 station | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ101A-ROC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 1 station | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ102A-LOB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 2 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ102A-LOC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 2 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ102A-ROB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 2 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ102A-ROC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 2 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ103A-LOB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 3 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ103A-LOC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 3 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ103A-ROB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 3 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ103A-ROC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 3 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ104A-LOB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 4 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ104A-LOC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 4 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ104A-ROB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 4 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ104A-ROC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 4 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ105A-LOB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 5 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ105A-LOC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 5 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ105A-ROB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 5 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ105A-ROC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 5 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ106A-LOB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 6 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ106A-LOC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 6 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ106A-ROB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 6 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ106A-ROC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 6 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ107A-LOB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 7 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ107A-LOC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 7 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ107A-ROB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 7 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ107A-ROC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 7 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ108A-LOB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 8 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ108A-LOC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 8 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV left, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ108A-ROB\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 8 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, PD via PS port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZZQ108A-ROC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eItem: Manifold base, 8 stations | Valves: Not applicable | Pressure switch: Not applicable | Display unit: Not applicable | Fittings: PV right, separate PD port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521620934946,"sku":"ZQ-A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-zq-a-thin-vacuum-unit-vacuum-pump-system.jpg?v=1791950458","url":"https:\/\/prosourcemro.com\/products\/smc-zq-a-thin-vacuum-unit-vacuum-pump-system","provider":"ProSource MRO","version":"1.0","type":"link"}