{"product_id":"smc-zse10-ise10-thin-digital-pressure-switch","title":"SMC ZSE10(F)\/ISE10 Thin Digital Pressure Switch (9.8 mm, 2 Outputs)","description":"\u003cp class=\"ps-intro\"\u003eSMC ZSE10(F)\/ISE10 thin 9.8 mm digital pressure switch with 2 NPN or PNP outputs for vacuum, compound or positive pressure.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003e9.8 mm thin body halves vertical mounting space; multi-angle OUT1\/OUT2 indicator lamps\u003c\/li\u003e\n\u003cli\u003eCopy function transfers settings to up to 10 switches at once; 3-step setting\u003c\/li\u003e\n\u003cli\u003eM5 female piping, side or bottom; R1\/8 and NPT1\/8 adapters made to order\u003c\/li\u003e\n\u003cli\u003eAnalog voltage output types (C, E) are made to order\u003c\/li\u003e\n\u003cli\u003eConnector lead wire G (5-core 2 m with cover), panel mount adapter + front cover D, DIN rail adapter R and calibration certificate K ordered as suffixes\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir, non-corrosive gas, non-flammable gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003eZSE10(F) 500 kPa; ISE10 1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply voltage\u003c\/th\u003e\n\u003ctd\u003e12 to 24 VDC, ripple 10% or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd\u003e40 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch output\u003c\/th\u003e\n\u003ctd\u003eNPN or PNP open collector 2 outputs, 80 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse time\u003c\/th\u003e\n\u003ctd\u003e2.5 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003e±0.2% F.S. ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e3 1\/2-digit 7-segment LED, 1-color (red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eCE, UL\/CSA (E216656), RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog ZSE10(F)\/ISE10 (SMCKR_ZSE10_F__ISE10.pdf), p. 67-70 (PDF p. 1-4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10-M5-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10: vacuum 0 to -101 kPa | Piping: M5 female, side | Output: NPN 2 outputs | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10-M5-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10: vacuum 0 to -101 kPa | Piping: M5 female, side | Output: NPN 2 outputs | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10-M5-A-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10: vacuum 0 to -101 kPa | Piping: M5 female, side | Output: NPN 2 outputs | Unit: Unit switching, initial psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10-M5-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10: vacuum 0 to -101 kPa | Piping: M5 female, side | Output: PNP 2 outputs | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10-M5-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10: vacuum 0 to -101 kPa | Piping: M5 female, side | Output: PNP 2 outputs | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10-M5-B-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10: vacuum 0 to -101 kPa | Piping: M5 female, side | Output: PNP 2 outputs | Unit: Unit switching, initial psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10-M5R-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10: vacuum 0 to -101 kPa | Piping: M5 female, bottom | Output: NPN 2 outputs | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10-M5R-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10: vacuum 0 to -101 kPa | Piping: M5 female, bottom | Output: NPN 2 outputs | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10-M5R-A-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10: vacuum 0 to -101 kPa | Piping: M5 female, bottom | Output: NPN 2 outputs | Unit: Unit switching, initial psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10-M5R-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10: vacuum 0 to -101 kPa | Piping: M5 female, bottom | Output: PNP 2 outputs | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10-M5R-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10: vacuum 0 to -101 kPa | Piping: M5 female, bottom | Output: PNP 2 outputs | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10-M5R-B-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10: vacuum 0 to -101 kPa | Piping: M5 female, bottom | Output: PNP 2 outputs | Unit: Unit switching, initial psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10F-M5-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10F: compound -100 to 100 kPa | Piping: M5 female, side | Output: NPN 2 outputs | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10F-M5-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10F: compound -100 to 100 kPa | Piping: M5 female, side | Output: NPN 2 outputs | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10F-M5-A-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10F: compound -100 to 100 kPa | Piping: M5 female, side | Output: NPN 2 outputs | Unit: Unit switching, initial psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10F-M5-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10F: compound -100 to 100 kPa | Piping: M5 female, side | Output: PNP 2 outputs | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10F-M5-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10F: compound -100 to 100 kPa | Piping: M5 female, side | Output: PNP 2 outputs | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10F-M5-B-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10F: compound -100 to 100 kPa | Piping: M5 female, side | Output: PNP 2 outputs | Unit: Unit switching, initial psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10F-M5R-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10F: compound -100 to 100 kPa | Piping: M5 female, bottom | Output: NPN 2 outputs | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10F-M5R-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10F: compound -100 to 100 kPa | Piping: M5 female, bottom | Output: NPN 2 outputs | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10F-M5R-A-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10F: compound -100 to 100 kPa | Piping: M5 female, bottom | Output: NPN 2 outputs | Unit: Unit switching, initial psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10F-M5R-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10F: compound -100 to 100 kPa | Piping: M5 female, bottom | Output: PNP 2 outputs | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10F-M5R-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10F: compound -100 to 100 kPa | Piping: M5 female, bottom | Output: PNP 2 outputs | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE10F-M5R-B-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE10F: compound -100 to 100 kPa | Piping: M5 female, bottom | Output: PNP 2 outputs | Unit: Unit switching, initial psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE10-M5-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE10: positive -0.1 to 1 MPa | Piping: M5 female, side | Output: NPN 2 outputs | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE10-M5-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE10: positive -0.1 to 1 MPa | Piping: M5 female, side | Output: NPN 2 outputs | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE10-M5-A-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE10: positive -0.1 to 1 MPa | Piping: M5 female, side | Output: NPN 2 outputs | Unit: Unit switching, initial psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE10-M5-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE10: positive -0.1 to 1 MPa | Piping: M5 female, side | Output: PNP 2 outputs | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE10-M5-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE10: positive -0.1 to 1 MPa | Piping: M5 female, side | Output: PNP 2 outputs | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE10-M5-B-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE10: positive -0.1 to 1 MPa | Piping: M5 female, side | Output: PNP 2 outputs | Unit: Unit switching, initial psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE10-M5R-A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE10: positive -0.1 to 1 MPa | Piping: M5 female, bottom | Output: NPN 2 outputs | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE10-M5R-A-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE10: positive -0.1 to 1 MPa | Piping: M5 female, bottom | Output: NPN 2 outputs | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE10-M5R-A-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE10: positive -0.1 to 1 MPa | Piping: M5 female, bottom | Output: NPN 2 outputs | Unit: Unit switching, initial psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE10-M5R-B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE10: positive -0.1 to 1 MPa | Piping: M5 female, bottom | Output: PNP 2 outputs | Unit: Unit switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE10-M5R-B-M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE10: positive -0.1 to 1 MPa | Piping: M5 female, bottom | Output: PNP 2 outputs | Unit: SI units fixed (kPa\/MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE10-M5R-B-P\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE10: positive -0.1 to 1 MPa | Piping: M5 female, bottom | Output: PNP 2 outputs | Unit: Unit switching, initial psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521660813602,"sku":"ZSE10","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-zse10-ise10-thin-digital-pressure-switch.jpg?v=1791950458","url":"https:\/\/prosourcemro.com\/products\/smc-zse10-ise10-thin-digital-pressure-switch","provider":"ProSource MRO","version":"1.0","type":"link"}