{"product_id":"smc-zse20-ise20-digital-pressure-switch","title":"SMC ZSE20(F)\/ISE20 3-Screen Digital Pressure Switch (1 Output, IP40)","description":"\u003cp class=\"ps-intro\"\u003eSMC ZSE20(F)\/ISE20 3-screen high-precision digital pressure switch with one NPN or PNP switch output, for vacuum, compound or positive pressure.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003e3-screen display shows current value, set value and label at once; simple 3-step setting\u003c\/li\u003e\n\u003cli\u003eVacuum (ZSE20), compound (ZSE20F) and positive pressure (ISE20) models\u003c\/li\u003e\n\u003cli\u003ePiping: M5 female, R1\/8, straight or elbow one-touch fittings (ø4, ø6, ø1\/4 in), or bottom wiring R1\/8\u003c\/li\u003e\n\u003cli\u003eChattering prevention delay 1.5 ms to 5000 ms, digital filter, peak\/bottom hold, key lock\u003c\/li\u003e\n\u003cli\u003eConnector lead wire, brackets A\/B, panel mount adapter (+ front cover), and English\/Japanese manual or calibration certificate (Y\/K\/T) are ordered as suffixes; listed codes are without these options (lead wire option L: 3-core 2 m or 3 m)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003ctd\u003eAir, non-corrosive gas, non-flammable gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof pressure\u003c\/th\u003e\n\u003ctd\u003eZSE: 500 kPa; ISE: 1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply voltage\u003c\/th\u003e\n\u003ctd\u003e12 to 24 VDC ±10%, ripple 10% or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e3-screen LCD (main red\/green, 2 sub screens orange)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay accuracy\u003c\/th\u003e\n\u003ctd\u003e±2% F.S. ±1 digit (25±3°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003e±0.2% F.S. ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch output\u003c\/th\u003e\n\u003ctd\u003eMax. load 80 mA, residual voltage 1 V or less, response 1.5 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent consumption\u003c\/th\u003e\n\u003ctd\u003e25 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL\/CSA (E216656), CE\/UKCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSMC Korea catalog ZSE20(F)\/ISE20 (SMCKR_ZSE20_F__ISE20.pdf), p. 11-13 (PDF p. 12-14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-M-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-M-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-M-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-M-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-M-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-M-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-M-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-M-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-M-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-P-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-P-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-P-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-P-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-P-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-P-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-P-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-P-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-N-P-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-M-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-M-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-M-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-M-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-M-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-M-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-M-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-M-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-M-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-P-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-P-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-P-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-P-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-P-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-P-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-P-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-P-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20-P-P-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20: vacuum 0 to -101 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-M-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-M-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-M-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-M-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-M-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-M-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-M-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-M-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-M-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-P-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-P-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-P-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-P-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-P-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-P-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-P-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-P-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-N-P-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-M-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-M-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-M-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-M-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-M-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-M-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-M-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-M-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-M-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-P-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-P-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-P-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-P-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-P-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-P-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-P-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-P-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZSE20F-P-P-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ZSE20F: compound -100 to 100 kPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-M-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-M-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-M-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-M-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-M-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-M-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-M-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-M-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-M-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-P-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-P-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-P-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-P-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-P-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-P-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-P-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-P-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-N-P-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: NPN 1 output | Unit: Unit switching, initial psi | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-M-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-M-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-M-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-M-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-M-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-M-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-M-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-M-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-M-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: SI units fixed (kPa\/MPa) | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-P-M5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: M5 female, back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-P-01\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: R1\/8 (M5 female), back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-P-C4H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø4 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-P-C6H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø6 one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-P-N7H\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø1\/4 in one-touch, straight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-P-C4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø4 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-P-C6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø6 one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-P-N7L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: ø1\/4 in one-touch, elbow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE20-P-P-01B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries: ISE20: positive -0.1 to 1 MPa | Output: PNP 1 output | Unit: Unit switching, initial psi | Piping: R1\/8 (M5 female), bottom wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SMC","offers":[{"title":"Default Title","offer_id":67521659568418,"sku":"ZSE20","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/smc-zse20-ise20-digital-pressure-switch.jpg?v=1791950457","url":"https:\/\/prosourcemro.com\/products\/smc-zse20-ise20-digital-pressure-switch","provider":"ProSource MRO","version":"1.0","type":"link"}