{"product_id":"spg-pak-040-small-flange-mount-parallel-shaft-geared-motors","title":"SPG PAK 0.4 kW Small Flange-Mount Geared Motors (1\/5-1\/200)","description":"\u003cp class=\"ps-intro\"\u003eSPG PAK series 0.4 kW three-phase four-pole parallel shaft industrial geared motors, small flange mounted, ratios 1\/5 to 1\/200.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eGear frames 22\/28\/32 (frame number = output shaft diameter in mm)\u003c\/li\u003e\n\u003cli\u003eEvery printed reduction ratio from 1\/5 to 1\/200\u003c\/li\u003e\n\u003cli\u003eMotor options: lead box (A), terminal box (B), terminal box + brake IP40 (C) or closed brake IP55 (D)\u003c\/li\u003e\n\u003cli\u003eVoltage codes R4, W6 and X6 for Korean, Japanese and 400 V class supplies\u003c\/li\u003e\n\u003cli\u003eTerminal box positions T\/L\/R\/B (12 o'clock, 9 o'clock, 3 o'clock, 6 o'clock)\u003c\/li\u003e\n\u003cli\u003eOil seal and low-noise fan; totally enclosed fan-cooled motor\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePAK (PA parallel shaft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eSmall flange, code K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor output\u003c\/th\u003e\n\u003ctd\u003e0.4 kW, 4 pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency grade\u003c\/th\u003e\n\u003ctd\u003eStandard efficiency (M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty\u003c\/th\u003e\n\u003ctd\u003eContinuous (S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eIP55 (IP40 for option C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eSPG Industrial Motor catalog, p. 33-36, 61-69, 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-5-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/5 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-10-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/10 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-15-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/15 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-20-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/20 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK22-25-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 22 | Ratio: 1\/25 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-30-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/30 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-40-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/40 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-50-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/50 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-60-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/60 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-80-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/80 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK28-100-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 28 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-100-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/100 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-120-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/120 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-160-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/160 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MA040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MA040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MA040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MA040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Lead box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MA040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MA040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MA040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MA040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Lead box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MA040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MA040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MA040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MA040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Lead box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MB040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MB040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MB040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MB040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MB040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MB040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MB040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MB040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MB040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MB040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MB040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MB040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MC040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MC040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MC040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MC040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MC040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MC040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MC040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MC040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MC040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MC040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MC040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MC040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + brake, IP40 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MD040R4T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MD040R4L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MD040R4R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MD040R4B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 220\/380 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MD040W6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MD040W6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MD040W6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MD040W6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 200 V 50 Hz, 200\/220 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MD040X6T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 12 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MD040X6L\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 9 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MD040X6R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 3 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePAK32-200-MD040X6B\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGear frame: 32 | Ratio: 1\/200 | Motor option: Terminal box + closed brake, IP55 | Voltage: 3-ph 380\/400 V 50 Hz, 400\/440 V 60 Hz | Box position: 6 o'clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"SPG","offers":[{"title":"Default Title","offer_id":67528244429090,"sku":"PAK22-5-MA040R4T","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/spg-pak-040-small-flange-mount-parallel-shaft-geared-motors.jpg?v=1792040656","url":"https:\/\/prosourcemro.com\/products\/spg-pak-040-small-flange-mount-parallel-shaft-geared-motors","provider":"ProSource MRO","version":"1.0","type":"link"}