{"product_id":"wonkwang-wk-three-phase-hot-air-blower","title":"Wonkwang WK Hot Air Blower (3-phase 220\/380\/440V, 5-68 kW)","description":"\u003cp class=\"ps-intro\"\u003eIndustrial WK-series electric hot air blowers for three-phase 220V, 380V or 440V supply, from 5 kW up to 68 kW. Forward, reverse (terminal box opposite) and heat-return (S) versions are offered, with optional mounted control panel.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eStainless heater body with CA (K-type) outlet sensor and dial thermometer\u003c\/li\u003e\n\u003cli\u003eInlet-side thermostat (320 C) overheat protection on WK-10\/WK-10M\u003c\/li\u003e\n\u003cli\u003eReturn-air (S) versions recirculate hot air for energy saving\u003c\/li\u003e\n\u003cli\u003eVoltage selectable: 3-phase 220V, 380V or 440V\u003c\/li\u003e\n\u003cli\u003eReplaceable heater body and ceramic insulators\u003c\/li\u003e\n\u003cli\u003eControl-panel-mounted versions available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eWonkwang Heating System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eWK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e3-phase 220V \/ 380V \/ 440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeater capacity\u003c\/th\u003e\n\u003ctd\u003e5-68 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAirflow\u003c\/th\u003e\n\u003ctd\u003e7-65 m3\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStatic pressure\u003c\/th\u003e\n\u003ctd\u003e75-380 mmAq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensors\u003c\/th\u003e\n\u003ctd\u003eCA (K-type) outlet sensor, thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVersions\u003c\/th\u003e\n\u003ctd\u003eForward, reverse, return-air (S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eBimetal overheat sensor with alarm and breaker trip required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003ctd\u003eWonkwang Heating System hot air blower board, model drawings and instruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 5 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 7.5 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-5K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 5 kW | Power: 3-ph 220\/380\/440V | Blower: 7 m3\/min, 75 mmAq, 190 W | Current 380V: 8.3 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-5K CONTROL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 5 kW | Power: 3-ph 220\/380\/440V | Blower: 7 m3\/min, 75 mmAq, 190 W | Current 380V: 8.3 A | Version: Controller mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-7\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 7 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 10 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-7K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 5 or 7 kW | Power: 3-ph 220\/380\/440V | Blower: 17.5 m3\/min, 120 mmAq, 500 W | Current 380V: 10 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-B7K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 7 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 10 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 12 kW | Power: 3-ph 220\/380\/440V | Blower: 17.5 m3\/min, 120 mmAq, 500 W | Current 380V: 18 A | Version: Forward \/ reverse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-10K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 14 kW | Power: 3-ph 220\/380\/440V | Blower: 23 m3\/min, 190 mmAq, 830 W | Current 380V: 21 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-10K(S)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 14 kW | Power: 3-ph 220\/380\/440V | Blower: 23 m3\/min, 190 mmAq, 830 W | Current 380V: 21 A | Version: Return, controller mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-10KK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 14 kW | Power: 3-ph 220\/380\/440V | Blower: 26 m3\/min, 265 mmAq, 1300 W | Current 380V: 21 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-10M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 12-14 kW | Power: 3-ph 220\/380\/440V | Blower: 17.5 m3\/min, 120 mmAq, 500 W | Current 380V: 21 A | Version: Reverse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-10M(S)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 12-14 kW | Power: 3-ph 220\/380\/440V | Blower: 17.5 m3\/min, 120 mmAq, 500 W | Current 380V: 21 A | Version: Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-10MK(S)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 14 kW | Power: 3-ph 220\/380\/440V | Blower: 20 m3\/min, 170 mmAq, 670 W | Current 380V: 21 A | Version: Return, 125 mm outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-10R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 14 kW | Power: 3-ph 220\/380\/440V | Blower: 10 m3\/min, 350 mmAq, 1060 W | Current 380V: 21 A | Version: High pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-20K(S)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 18 or 21 kW | Power: 3-ph 220\/380\/440V | Blower: 23 m3\/min, 190 mmAq, 830 W | Current 380V: 27 A | Version: Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-20KK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 21 kW | Power: 3-ph 220\/380\/440V | Blower: 26 m3\/min, 265 mmAq, 1300 W | Current 380V: 32 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-20KK(S)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 21 kW | Power: 3-ph 220\/380\/440V | Blower: 26 m3\/min, 265 mmAq, 1300 W | Current 380V: 32 A | Version: Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-20M\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 18 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 27 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-20R\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 18 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 27 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-20R2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 21 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 32 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 24 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 36 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-30K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 24 or 28 kW | Power: 3-ph 220\/380\/440V | Blower: 26 m3\/min, 265 mmAq, 1300 W | Current 380V: 36 \/ 42.5 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-30KK(S)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 28 kW | Power: 3-ph 220\/380\/440V | Blower: 40 m3\/min, 285 mmAq, 1630 W | Current 380V: 42.5 A | Version: Return, reverse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 30 or 36 kW | Power: 3-ph 220\/380\/440V | Blower: 40 m3\/min, 285 mmAq, 1630 W | Current 380V: 45.5 \/ 55 A | Version: Standard \/ controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-40K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 30 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 45.5 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-40KK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 30 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 45.5 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-45\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 36 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 55 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-45K\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 36 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 55 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-45KK\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 36 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 55 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-50\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 45 or 50 kW | Power: 3-ph 220\/380\/440V | Blower: 52 m3\/min, 320 mmAq, 2600 W | Current 380V: 68 A | Version: Reverse, stainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-50(S)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 45 or 50 kW | Power: 3-ph 220\/380\/440V | Blower: 52 m3\/min, 320 mmAq, 2600 W | Current 380V: 68 A | Version: Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-60\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 55 kW | Power: 3-ph 220\/380\/440V | Blower: On request | Current 380V: 83 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWK-70\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHeater: 65-68 kW | Power: 3-ph 220\/380\/440V | Blower: 65 m3\/min, 380 mmAq, 3770 W | Current 380V: 97 A | Version: Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Wonkwang Heating System","offers":[{"title":"Default Title","offer_id":67630142226722,"sku":"WK-5","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/wonkwang-wk-three-phase-hot-air-blower.jpg?v=1793244962","url":"https:\/\/prosourcemro.com\/products\/wonkwang-wk-three-phase-hot-air-blower","provider":"ProSource MRO","version":"1.0","type":"link"}