{"product_id":"woonyoung-economy-three-phase-ssr-wyl3g3-wyl3h3-10-80a","title":"Woonyoung Economy Three Phase SSR WYL3G3 \/ WYL3H3 (10-80A)","description":"\u003cp class=\"ps-intro\"\u003eEconomy three-phase SSR with height reduced by about 10 mm and a redesigned protective cover, rated 10-80A with LED input indication.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eLow profile (about 10 mm lower)\u003c\/li\u003e\n\u003cli\u003eZero cross or random switching\u003c\/li\u003e\n\u003cli\u003eDC or AC control input\u003c\/li\u003e\n\u003cli\u003eLED status indicator\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C10Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C10R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C10Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C10R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C15Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 15 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 160 A | Contact voltage drop: 1.7 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C15R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 15 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 160 A | Contact voltage drop: 1.7 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C15Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 15 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 160 A | Contact voltage drop: 1.7 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C15R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 15 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 160 A | Contact voltage drop: 1.7 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C20Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C20R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C20Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C20R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C25Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 25 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C25R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 25 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C25Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 25 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C25R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 25 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C30Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C30R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C30Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C30R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C40Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C40R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C40Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C40R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C50Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 350 A | Contact voltage drop: 2.0 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C50R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 350 A | Contact voltage drop: 2.0 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C50Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 350 A | Contact voltage drop: 2.0 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C50R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 350 A | Contact voltage drop: 2.0 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C60Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 400 A | Contact voltage drop: 2.5 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C60R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 400 A | Contact voltage drop: 2.5 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C60Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 400 A | Contact voltage drop: 2.5 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C60R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 400 A | Contact voltage drop: 2.5 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C80Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 450 A | Contact voltage drop: 3.0 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C80R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 450 A | Contact voltage drop: 3.0 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C80Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 450 A | Contact voltage drop: 3.0 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3G3C80R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 450 A | Contact voltage drop: 3.0 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C10Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 125 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C10R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 125 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C10Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 125 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C10R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 125 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C15Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 15 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 160 A | Contact voltage drop: 1.7 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C15R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 15 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 160 A | Contact voltage drop: 1.7 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C15Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 15 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 160 A | Contact voltage drop: 1.7 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C15R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 15 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 160 A | Contact voltage drop: 1.7 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C20Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C20R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C20Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C20R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C25Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 25 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C25R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 25 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C25Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 25 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C25R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 25 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 300 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C30Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C30R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C30Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C30R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C40Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C40R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C40Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C40R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 315 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C50Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 350 A | Contact voltage drop: 2.0 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C50R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 350 A | Contact voltage drop: 2.0 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C50Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 350 A | Contact voltage drop: 2.0 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C50R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 350 A | Contact voltage drop: 2.0 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C60Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 400 A | Contact voltage drop: 2.5 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C60R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 400 A | Contact voltage drop: 2.5 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C60Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 400 A | Contact voltage drop: 2.5 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C60R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 400 A | Contact voltage drop: 2.5 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C80Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 450 A | Contact voltage drop: 3.0 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C80R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 450 A | Contact voltage drop: 3.0 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C80Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 450 A | Contact voltage drop: 3.0 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYL3H3C80R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1200 V | Peak surge current: 450 A | Contact voltage drop: 3.0 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Woonyoung","offers":[{"title":"Default Title","offer_id":67495134265634,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/woonyoung-economy-three-phase-ssr-wyl3g3-wyl3h3-10-80a-1.jpg?v=1791595904","url":"https:\/\/prosourcemro.com\/products\/woonyoung-economy-three-phase-ssr-wyl3g3-wyl3h3-10-80a","provider":"ProSource MRO","version":"1.0","type":"link"}