{"product_id":"woonyoung-general-type-single-phase-ssr-wyg-wyh-10-80a","title":"Woonyoung General Type Single Phase SSR WYG \/ WYH (10-80A)","description":"\u003cp class=\"ps-intro\"\u003eGeneral-type single-phase SSR series rated AC 90-240V (WYG) or 90-480V (WYH), 10-80A, for resistive and general inductive loads, with an LED showing ON\/OFF state.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003ecUL certified (10-40 A Z4 types, UL508)\u003c\/li\u003e\n\u003cli\u003eZero cross (Z) or random (R) switching\u003c\/li\u003e\n\u003cli\u003eDC 4-32 V or AC 90-240 V control input\u003c\/li\u003e\n\u003cli\u003eLED status indicator\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLeakage current\u003c\/th\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C10Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C10R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C10Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C10R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C20Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C20R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C20Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C20R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 20 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C30Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C30R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C30Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C30R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 30 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C40Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C40R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C40Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C40R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C50Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C50R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C50Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C50R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 50 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C60Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C60R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C60Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C60R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C80Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C80R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C80Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYG1C80R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C10Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C10R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C10Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C10R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 125 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C20Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C20R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C20Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C20R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 20 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 300 A | Contact voltage drop: 1.5 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C30Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C30R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C30Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C30R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 30 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C40Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C40R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C40Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C40R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 315 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C50Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C50R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C50Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C50R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 50 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C60Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C60R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C60Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C60R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.3 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C80Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C80R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C80Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYH1C80R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 525 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Woonyoung","offers":[{"title":"Default Title","offer_id":67495134036258,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/woonyoung-general-type-single-phase-ssr-wyg-wyh-10-80a-1.jpg?v=1791595904","url":"https:\/\/prosourcemro.com\/products\/woonyoung-general-type-single-phase-ssr-wyg-wyh-10-80a","provider":"ProSource MRO","version":"1.0","type":"link"}