{"product_id":"woonyoung-single-phase-ssr-with-self-heat-sink-wymg-wymh-10-40a","title":"Woonyoung Single Phase SSR with Self Heat Sink WYMG \/ WYMH (10-40A)","description":"\u003cp class=\"ps-intro\"\u003eIntegrated single-phase SSR with self heat sink rated AC 90-240V or 90-480V, 10-40A, saving installation space and mountable on DIN rail.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003eIntegrated heat sink\u003c\/li\u003e\n\u003cli\u003eDIN rail mountable\u003c\/li\u003e\n\u003cli\u003eZero cross or random switching\u003c\/li\u003e\n\u003cli\u003eDC or AC control input\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDielectric strength\u003c\/th\u003e\n\u003ctd\u003e2000 VAC \/ 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C10Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 170 A | Contact voltage drop: 1.95 V | Control input: DC 4-32V | Switching: Zero cross | Weight: 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C10R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 170 A | Contact voltage drop: 1.95 V | Control input: DC 4-32V | Switching: Random (non zero cross) | Weight: 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C10Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 170 A | Contact voltage drop: 1.95 V | Control input: AC 90-240V | Switching: Zero cross | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C10R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 170 A | Contact voltage drop: 1.95 V | Control input: AC 90-240V | Switching: Random (non zero cross) | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C15Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 15 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 250 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross | Weight: 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C15R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 15 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 250 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross) | Weight: 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C15Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 15 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 250 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C15R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 15 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 250 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross) | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C25Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 25 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 350 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross | Weight: 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C25R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 25 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 350 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross) | Weight: 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C25Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 25 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 350 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C25R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 25 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 350 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross) | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C40Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 370 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross | Weight: 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C40R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 370 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross) | Weight: 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C40Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 370 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMG1C40R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 600 V | Peak surge current: 370 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross) | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C10Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 170 A | Contact voltage drop: 1.95 V | Control input: DC 4-32V | Switching: Zero cross | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C10R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 170 A | Contact voltage drop: 1.95 V | Control input: DC 4-32V | Switching: Random (non zero cross) | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C10Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 170 A | Contact voltage drop: 1.95 V | Control input: AC 90-240V | Switching: Zero cross | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C10R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 10 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 170 A | Contact voltage drop: 1.95 V | Control input: AC 90-240V | Switching: Random (non zero cross) | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C15Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 15 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 250 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C15R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 15 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 250 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross) | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C15Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 15 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 250 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C15R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 15 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 250 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross) | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C25Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 25 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 350 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C25R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 25 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 350 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross) | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C25Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 25 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 350 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C25R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 25 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 350 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross) | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C40Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 370 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C40R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 370 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross) | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C40Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 370 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYMH1C40R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 1 | Rated load current: 40 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 800\/1200 V | Peak surge current: 370 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross) | Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Woonyoung","offers":[{"title":"Default Title","offer_id":67495134101794,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/woonyoung-single-phase-ssr-with-self-heat-sink-wymg-wymh-10-40a-1.jpg?v=1791595923","url":"https:\/\/prosourcemro.com\/products\/woonyoung-single-phase-ssr-with-self-heat-sink-wymg-wymh-10-40a","provider":"ProSource MRO","version":"1.0","type":"link"}