{"product_id":"woonyoung-three-phase-ssr-with-heat-sink-and-fan-wyfm3g3-wyfm3h3-60-150a","title":"Woonyoung Three Phase SSR with Heat Sink and Fan WYFM3G3 \/ WYFM3H3 (60-150A)","description":"\u003cp class=\"ps-intro\"\u003eLarge-capacity integral three-phase SSR with fan and heat sink, rated 60-150A, designed for convenient use without an additional heat sink.\u003c\/p\u003e\u003ch4 class=\"ps-h\"\u003eKey features\u003c\/h4\u003e\u003cul class=\"ps-feat\"\u003e\n\u003cli\u003e60 \/ 80 \/ 100 \/ 150 A\u003c\/li\u003e\n\u003cli\u003eIntegrated heat sink and fan\u003c\/li\u003e\n\u003cli\u003eZero cross or random switching\u003c\/li\u003e\n\u003cli\u003eDC or AC control input\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4 class=\"ps-h\"\u003eSpecifications\u003c\/h4\u003e\u003ctable class=\"ps-kv\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e5.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"ps-src\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C60Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 1300 A | Contact voltage drop: 1.95 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C60R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 1300 A | Contact voltage drop: 1.95 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C60Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 1300 A | Contact voltage drop: 1.95 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C60R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 1300 A | Contact voltage drop: 1.95 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C80Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 1750 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C80R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 1750 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C80Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 1750 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C80R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 1750 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C100Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 100 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 1950 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C100R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 100 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 1950 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C100Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 100 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 1950 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C100R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 100 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 1950 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C150Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 150 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 2550 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C150R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 150 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 2550 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C150Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 150 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 2550 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3G3C150R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 150 A | Rated voltage: 220 VAC | Voltage range: 90-240 VAC | Peak voltage: 1600 V | Peak surge current: 2550 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C60Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 1300 A | Contact voltage drop: 1.95 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C60R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 1300 A | Contact voltage drop: 1.95 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C60Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 1300 A | Contact voltage drop: 1.95 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C60R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 60 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 1300 A | Contact voltage drop: 1.95 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C80Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 1750 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C80R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 1750 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C80Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 1750 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C80R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 80 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 1750 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C100Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 100 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 1950 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C100R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 100 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 1950 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C100Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 100 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 1950 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C100R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 100 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 1950 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C150Z4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 150 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 2550 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C150R4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 150 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 2550 A | Contact voltage drop: 1.8 V | Control input: DC 4-32V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C150Z40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 150 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 2550 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Zero cross\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWYFM3H3C150R40\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase: 3 | Rated load current: 150 A | Rated voltage: 440 VAC | Voltage range: 90-480 VAC | Peak voltage: 1600 V | Peak surge current: 2550 A | Contact voltage drop: 1.8 V | Control input: AC 90-240V | Switching: Random (non zero cross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Woonyoung","offers":[{"title":"Default Title","offer_id":67495134331170,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/0744\/7586\/files\/woonyoung-three-phase-ssr-with-heat-sink-and-fan-wyfm3g3-wyfm3h3-60-150a-1.jpg?v=1791595923","url":"https:\/\/prosourcemro.com\/products\/woonyoung-three-phase-ssr-with-heat-sink-and-fan-wyfm3g3-wyfm3h3-60-150a","provider":"ProSource MRO","version":"1.0","type":"link"}